NJT Automation has supplied and shipped 9 1747-L553 SLC 5/05 PLC Processors since 2025; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 9 since 2025
- Series
- C × 3, A × 2, B × 2, D × 2
In stock: 2 units in Milwaukee, WI.
SLC 5/05 PLC Processor · 64K Words User Memory · channel 0 RS-232 (DF1 / DH-485 / ASCII) and channel 1 Ethernet (10Base-T; 10/100 on later series)

Actual NJT inventory photos
| Part Number | 1747-L553 |
| Description | SLC 5/05 PLC Processor, 64K Memory, Ethernet. In stock in used condition, Series B and C. |
| Shipping | Ships same or next business day
|
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 1747-L553 for a 10% core credit. |
| Variants | |||||||||||||||||||||||||||
| Availability | 2 Units in StockIndependently SourcedNot an OEM-Authorized Distributor | ||||||||||||||||||||||||||
| Repairs | 1747-L553 Mail-In Repair Service | Flat RateFlat rate: $949.99 | ||||||||||||||||||||||||||
Part Number Decoder | SLC 5/05 PLC Processor 1747·L·5·5·3
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||||||||||||||||||||
Series & Revisions | Series B and C in stock; other series on request. Series A shipped with OS500 and can be flashed to OS501; Series B and C ship with OS501. Only Series C hardware has the 10/100 Mbps Ethernet port; A and B run 10 Mbps half duplex. Series notes: Same slot and wiring. A later series runs an earlier program; an earlier series rejects a program that uses newer OS/FRN features. | ||||||||||||||||||||||||||
Intended Use | Intended for Ethernet-connected legacy machine and small-process control applications. SLC 500 processors still run packaging lines, conveyors, water and wastewater stations, HVAC plants and OEM machinery installed through the 1990s and 2000s. Most demand today is replacing a failed processor like-for-like so the existing rack, I/O and RSLogix 500 program stay in place. | ||||||||||||||||||||||||||
Physical Data | Weight and DimensionsEst. weight0.82 lb (0.37 kg)H × W × D5.7 × 1.4 × 5.7 in. (145 × 35 × 145 mm)▾
Product dimensions are typical manufacturer-published values and may differ by series or option. Unit weight is an estimate; no published figure is available for this catalog number. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||||||||||||||||||||
Similar Part Numbers | |||||||||||||||||||||||||||
Allen-Bradley Information | Technical Specifications12 parameters from manufacturer-published specifications▾
Typical manufacturer-published values for this catalog number; confirm against the current manufacturer documentation before specifying. | ||||||||||||||||||||||||||
| Category | SLC 500 | ||||||||||||||||||||||||||
| UPC / GTIN | 0662072745595 | ||||||||||||||||||||||||||
| Part Number | 1747-L553 | ||||||||||||||||||||||||||
| Manufacturer | Allen-Bradley | ||||||||||||||||||||||||||
NJT Automation has supplied and shipped 9 1747-L553 SLC 5/05 PLC Processors since 2025; these listings are sold and the in-stock options above are ready to ship.
Yes. NJT Automation repairs the 1747-L553 by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Failure patterns we regularly see on SLC 5/05 PLC Processor hardware like the 1747-L553:
Fault code reference
50 codes · 1747-RM001
Fault codes a SLC 5/05 PLC Processor reports on status word S:6 in RSLogix 500 (hexadecimal), as documented in Rockwell Automation publication 1747-RM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
| Code | Fault | What it indicates |
|---|---|---|
| 0001 | NVRAM error | Processor memory was corrupted: noise, lightning, poor grounding or missing surge suppression on inductive loads. The default program is loaded. |
| 0002 | Unexpected hardware watchdog timeout | The processor reset unexpectedly; usually electrical noise or a failing processor. |
| 0003 | Memory module memory error | The memory module is corrupted. This can also occur when going to REM Run mode. |
| 0004 | Memory error in Run mode | Processor memory became corrupt while running. |
| 0007 | Memory module transfer failure | Transfer from the memory module failed; the module is corrupted. |
| 0008 | Internal software error | Unexpected software error, typically caused by noise or a hardware problem. |
| 0009 | Internal hardware error | Unexpected hardware error inside the processor. |
| 0010 | Processor revision too low | The processor does not meet the revision level the program requires. |
| 0011 | Program file 2 absent | Executable program file number 2 is missing: incompatible or corrupt program. |
| 0012 | Ladder program memory error | The ladder program has a memory integrity problem. |
| 0013 | Memory module absent | The required memory module is absent, or S:1/10 / S:1/11 is not set as the program requires. |
| 0014 | Internal file error | Processor data files are corrupted. |
| 0015 | Configuration file error | The I/O configuration file is corrupted. |
| 0016 | Startup protection after power loss | S:1/9 is set and power was lost while running; the processor waits for the fault routine to clear it. |
| 0017 | NVRAM / memory module mismatch | S:2/9 is set and the memory module program does not match the NVRAM program. |
| 0018 | Incompatible user program | Operating system type mismatch: the program was written for a different or newer processor. |
| 0019 | Duplicate label | A duplicate or missing LBL instruction was found in a subroutine. |
| 001F | Online edit integrity problem | Noise, communication loss or a power cycle occurred during an online editing session. |
| 0020 | Minor error at end of scan | A minor error bit in S:5 (lower byte) was set at the end of the scan, for example a math overflow. |
| 0021 | Remote expansion chassis power failure | An expansion I/O chassis lost power, or an over-voltage / over-current condition occurred. |
| 0022 | Watchdog scan time exceeded | The program scan took longer than the watchdog setpoint, or the program is caught in a loop. |
| 0023 | Invalid STI interrupt file | The STI interrupt file number is invalid or the subroutine does not exist. |
| 0024 | Invalid STI interval | The STI setpoint is greater than 2550 ms or negative. |
| 0025–0027 | Excessive stack depth / JSR calls | A JSR instruction is calling the STI, I/O interrupt or user fault routine file directly. |
| 0028 | Invalid startup-protection fault routine | The fault routine file number in the status file does not exist or is invalid. |
| 0029–002D | Indexed / indirect address error | An indexed or indirect address references outside its data file or data space. |
| 002E | Invalid DII input slot | The DII slot is empty or does not hold a discrete input module. |
| 002F | Invalid DII interrupt file | The DII interrupt file number is invalid or the subroutine does not exist. |
| 0030 | Subroutine nesting exceeded | Too many nested JSRs, or potentially recursive routines. |
| 0031 | Unsupported instruction | The processor type or series does not support an instruction in the program. |
| 0032 | Sequencer out of range | A sequencer length / position parameter points past the end of a data file. |
| 0033 | Bit shift / FIFO / LIFO out of range | The length parameter of an LFU, LFL, FFU, FFL, BSL or BSR instruction points past the end of a data file. |
| 0034 | Negative timer value | A negative timer accumulator or preset value was detected. |
| 0035 | TND / SVC / REF in interrupt routine | A TND, SVC or REF instruction is used inside an interrupt or user fault routine. |
| 0036 | Invalid PID parameter | An invalid value is being used for a PID instruction parameter. |
| 0038 | RET outside subroutine | A RET instruction resides in the main program file. |
| 003A | Write to protected file | An attempt was made to write to a constant / protected data file. |
| 003B | Firmware mismatch | Motherboard and daughter card firmware were not flash-upgraded as a pair. |
| 003C | STI watchdog timeout | The STI setpoint is set too low for the routine. |
| 005F | Invalid rack ID | Invalid rack setup or a problem with the rack. |
| xx50 | Chassis data error | Slot xx returned bad chassis data; usually noise or grounding. |
| xx51 | Stuck runtime error | A stuck I/O module in slot xx: noise on a discrete module or a fault on a specialty module. |
| xx52 | Module missing | The module configured for slot xx is missing or was removed. |
| xx53 | Unused slot has module | A slot declared unused contains a module, or a module reset itself. |
| xx54 | Wrong module type | The module in slot xx is a different type than configured. |
| xx55 | Wrong I/O count | The discrete module in slot xx has a different I/O count than configured. |
| xx56 | Chassis configuration error | The chassis configuration in the program does not match the hardware. |
| xx57–xx5E | Specialty module error | A specialty I/O module in slot xx faulted, timed out or has an invalid G / M0-M1 file configuration. |
| xx90–xx93 | Disabled-slot / ISR error | A specialty module in a disabled slot requested service or faulted, or its interrupt subroutine is invalid. |
| xx94 | Module inserted under power | A module was inserted under power in Run or Test mode, or reset itself. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 1747-RM001, SLC 500 Instruction Set Reference Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.
Find answers to shipping, warranties, repairs, and more.
Trademarks & Compatibility
All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.
Independent Supplier
NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.
Product Condition & Warranty
Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.
Firmware & Software Licensing
Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.
NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.
© 2026 NJT Automation. Independent industrial automation supplier and repair provider.