NJT Automation has supplied and shipped 3 2093-AMP5 Kinetix 2000 axis modules since 2025; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 3 since 2025
- Series
- A × 3
In stock: 2 units in Milwaukee, WI.
Kinetix 2000 axis module: 0.9 kW / 3.0 A rms (4.24 A 0-pk) inverter axis on the shared 325V DC bus · sercos interface

Actual NJT inventory photos
| Part Number | 2093-AMP5 |
| Description | Kinetix 2000 axis module (AM), 0.9 kW, 200V-class. In stock in refurbished condition, Series A. |
| Shipping | Ships same or next business day
|
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 2093-AMP5 for a 10% core credit. |
| Variants | |||||||||||||||||||||
| Availability | 2 Units in StockIndependently SourcedNot an OEM-Authorized Distributor | ||||||||||||||||||||
| Repairs | 2093-AMP5 Mail-In Repair ServiceEstimated: $2,520.00 | ||||||||||||||||||||
Part Number Decoder | Kinetix 2000 axis module (AM) 2093·A·MP5
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||||||||||||||
Series & Revisions | Series A in stock; other series on request. | ||||||||||||||||||||
Intended Use | Built for compact multi-axis servo motion applications. Kinetix 2000 axis modules add axes on the shared power rail for low-power, multi-axis machines such as small packaging, labeling, converting and medical equipment, with SERCOS motion from a Logix controller. | ||||||||||||||||||||
Physical Data | Weight and DimensionsWeight1.48 lb (0.67 kg)▾
Product weight are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||||||||||||||
Similar Part Numbers |
| ||||||||||||||||||||
Allen-Bradley Information | Technical Specifications9 parameters from manufacturer-published specifications▾
Typical manufacturer-published values for this catalog number; confirm against the current manufacturer documentation before specifying. | ||||||||||||||||||||
| Category | Kinetix 2000 | ||||||||||||||||||||
| UPC / GTIN | 820919777233 | ||||||||||||||||||||
| Part Number | 2093-AMP5 | ||||||||||||||||||||
| Manufacturer | Allen-Bradley | ||||||||||||||||||||
NJT Automation has supplied and shipped 3 2093-AMP5 Kinetix 2000 axis modules since 2025; these listings are sold and the in-stock options above are ready to ship.
Yes. NJT Automation repairs the 2093-AMP5 by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Failure patterns we regularly see on Kinetix 2000 axis module (AM) hardware like the 2093-AMP5:
Fault code reference
40 codes · 2093-UM001
Fault codes a Kinetix 2000 axis module (AM) reports on the seven-segment status indicator on the IAM or AM module and the axis fault in RSLogix 5000, as documented in Rockwell Automation publication 2093-UM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
| Code | Fault | What it indicates |
|---|---|---|
| E00 | Blown fuse | A blown fuse was detected on the inverter board; the module needs repair. |
| E04 | Motor overtemperature | Motor thermal switch tripped: high ambient, excessive current, wiring error or wrong motor. |
| E05 | Drive overcurrent (power fault) | The Intelligent Power Module tripped: shorted motor cables or windings, drive too hot, or a failed power stage. |
| E06 | Hardware overtravel | The axis moved beyond the physical travel limit input. |
| E07 | Motor feedback loss | Motor feedback wiring is open, shorted or missing. |
| E09 | Bus undervoltage | DC bus below limit with three-phase power present, or power removed while an axis was enabled. |
| E10 | Bus overvoltage | DC bus above limit, usually excessive regeneration. |
| E11 | Illegal Hall state | Hall feedback inputs are in an invalid state; check wiring at the MF connector. |
| E16 | Software overtravel | Axis position exceeded the software travel limit. |
| E18 | Overspeed | Motor speed exceeded 150% of maximum rated speed. |
| E19 | Follow error | Position error limit exceeded; check tuning, feed-forward and mechanical load. |
| E20 | Motor feedback AQB | The motor encoder encountered an illegal quadrature transition, usually noise. |
| E21 | Aux feedback comm | Communication was not established with an intelligent auxiliary encoder. |
| E30 | Motor feedback comm | Communication was not established with the intelligent motor encoder. |
| E34 | Ground fault | Excessive ground current detected in the converter: wiring, motor ground short or internal fault. |
| E35 | Precharge fault | The converter precharge cycle failed: low AC input or an internal fault. |
| E36 | System overtemperature | Converter thermal switch tripped: excessive heat in the power circuitry. |
| E37 | Phase loss | One or more AC input phases missing, or the axis was enabled when main power was removed. |
| E38 | SERCOS ring fault | The SERCOS fiber ring dropped after being active; check fiber connections. |
| E39 | Self-sense fault | Self-sensing commutation start-up was obstructed. |
| E43 | Drive enable fault | Enable was attempted through software while the hardware enable input was inactive, or the input dropped. |
| E50 | SERCOS same address | Duplicate node address detected on the SERCOS ring. |
| E54 | Current feedback hardware fault | Current feedback hardware fault detected inside the drive; a hardware fault on the drive's control/power electronics that repair addresses. |
| E60 | Unknown axis | Illegal ID bits detected; a hardware fault inside the drive rather than in the wiring or application. |
| E61 / E62 | Aux feedback AQB / loss | Auxiliary encoder illegal transition, or auxiliary feedback wiring open / shorted / missing. |
| E65 | Hookup fault | The hookup test failed: motor power / feedback wiring or feedback device. |
| E66 | Autotune fault | The autotune procedure failed. |
| E67 | Task init | Operating system failed to initialize; hardware failure if it persists after a power cycle. |
| E68 | SCANport comm | DPI communication failed; check the device and cable. |
| E69 | Objects init | Non-volatile memory corrupt due to control-board hardware failure. |
| E70 | NV memory init | Non-volatile memory corrupt; load defaults and save. |
| E71 | Memory init | RAM or flash validation failure; if it persists through a power cycle, the fault is in the drive's control board. |
| E72 | Drive overtemperature | Inverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle. |
| E73 | Backplane comm | Power-rail CAN communication failed; check module seating and the power rail. |
| E74 | Bus overcurrent | DC link current exceeded rating; motor or transmission problem, or an undersized IAM. |
| E75 | Shunt time out | The IAM, AM or shunt module exceeded its shunt resistor continuous rating. |
| E76 | CAN init | DPI hardware initialization fault; control-board hardware failure. |
| E78 | SERCOS init | Control hardware fault detected at SERCOS initialization. |
| E79 | Shunt module fault | The shunt module reports a temperature or shunt fault, or is missing from the power rail. |
| E80 | CPLD fault | Control hardware fault detected; a fault inside the drive's control electronics. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 2093-UM001, Kinetix 2000 Multi-axis Servo Drives User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.
Find answers to shipping, warranties, repairs, and more.
Trademarks & Compatibility
All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.
Independent Supplier
NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.
Product Condition & Warranty
Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.
Firmware & Software Licensing
Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.
NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.