Kinetix 6000 200V-class integrated axis module (IAM): 11.3 kW converter (36 A DC) with a 5.5 kW / 25 A (0-pk) inverter axis · sercos interface · safe-off

Actual NJT inventory photos
Price
$4,099.99USDUsed, Series CView listing
| Part Number | 2094-AC16-M03-S |
| Description | Kinetix 6000 integrated axis module (IAM), 11.3 kW, 200V-class. In stock in used condition, Series C. |
| Shipping | Ships same or next business day
|
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 2094-AC16-M03-S for a 10% core credit. |
| Variants | Part NumberConditionSeriesQtyPrice 2094-AC16-M03-S /C$4,099.99 Used · Series C · 1 in stock2094-AC16-M03-S /CUsedSeries C1$4,099.99 USD | ||||||
| Availability | 1 Unit in StockIndependently SourcedNot an OEM-Authorized Distributor | ||||||
| Repairs | 2094-AC16-M03-S Mail-In Repair ServiceEstimated: $2,360.00 | ||||||
Part Number Decoder | Kinetix 6000 integrated axis module (IAM) 2094·A·C·16·M03·-S
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||
Series & Revisions | Series C in stock; other series on request. The -S (Kinetix 6000, SERCOS) and -M (Kinetix 6200 / 6500) suffixes are different control families and do not interchange on a rail. Series notes: Match the suffix. Within the same catalog number, flash the replacement to the firmware revision the Logix project expects before substituting. | ||||||
Intended Use | Designed for multi-axis coordinated servo motion applications. Kinetix 6000 integrated axis modules supply the DC bus and run the first axis for coordinated multi-axis machines: packaging, converting, printing, web handling, material handling and pick-and-place, with SERCOS or EtherNet/IP motion from a Logix controller. Safe Torque Off lets the drive sit in the machine's safety circuit without an external contactor. | ||||||
Physical Data | Weight and DimensionsWeight10.4 lb (4.71 kg)▾
Product weight are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||
Similar Part Numbers |
| ||||||
Allen-Bradley Information | Technical SpecificationsLifecycle status▾
| ||||||
| Category | Kinetix 6000 | ||||||
| UPC / GTIN | 0820919595585 | ||||||
| Part Number | 2094-AC16-M03-S | ||||||
| Manufacturer | Allen-Bradley | ||||||
NJT Automation has supplied and shipped one 2094-AC16-M03-S Kinetix 6000 integrated axis module in 2026; these listings are sold and the in-stock options above are ready to ship.
Yes. NJT Automation repairs the 2094-AC16-M03-S by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Failure patterns we regularly see on Kinetix 6000 integrated axis module (IAM) hardware like the 2094-AC16-M03-S:
Fault code reference
48 codes · 2094-UM001
Fault codes a Kinetix 6000 integrated axis module (IAM) reports on the seven-segment status indicator on the IAM or AM module and the axis fault in RSLogix 5000, as documented in Rockwell Automation publication 2094-UM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
| Code | Fault | What it indicates |
|---|---|---|
| E00 | Blown fuse | A blown fuse was detected on the inverter board; the module needs repair. |
| E04 | Motor overtemperature | Motor thermal switch tripped: high ambient, excessive current, wiring error or wrong motor. |
| E05 | Drive overcurrent (power fault) | The Intelligent Power Module tripped: shorted motor cables or windings, drive too hot, or a failed power stage. |
| E06 | Hardware overtravel | The axis moved beyond the physical travel limit input. |
| E07 | Motor feedback loss | Motor feedback wiring is open, shorted or missing. |
| E09 | Bus undervoltage | DC bus below limit with three-phase power present, or power removed while an axis was enabled. |
| E10 | Bus overvoltage | DC bus above limit, usually excessive regeneration; check shunt sizing. |
| E11 | Illegal Hall state | Hall feedback inputs are in an invalid state; check wiring at the MF connector. |
| E16 | Software overtravel | Axis position exceeded the software travel limit. |
| E18 | Overspeed | Motor speed exceeded 150% of maximum rated speed. |
| E19 | Follow error | Position error limit exceeded; check tuning, feed-forward and mechanical load. |
| E20 | Motor feedback AQB | The motor encoder encountered an illegal quadrature transition, usually noise. |
| E21 | Aux feedback comm | Communication was not established with an intelligent auxiliary encoder. |
| E30 | Motor feedback comm | Communication was not established with the intelligent motor encoder. |
| E31 | Shaft movement at power-up | Motor shaft moved during the power-up feedback test. |
| E34 | Ground fault | Excessive ground current detected in the converter: wiring, motor ground short or internal fault. |
| E35 | Precharge fault | The converter precharge cycle failed: low AC input or an internal fault. |
| E36 | System overtemperature | Converter thermal switch tripped: excessive heat in the power circuitry. |
| E37 | Phase loss | One or more AC input phases missing, or the axis was enabled when main power was removed. |
| E38 | SERCOS ring fault | The SERCOS fiber ring dropped after being active; check fiber connections. |
| E39 | Self-sense fault | Self-sensing commutation start-up was obstructed. |
| E43 | Drive enable fault | Enable was attempted through software while the hardware enable input was inactive, or the input dropped. |
| E49 | Safe-off hardware fault | The safe-off (STO) circuit reported a hardware fault. |
| E50 | SERCOS same address | Duplicate node address detected on the SERCOS ring. |
| E54 | Current feedback hardware fault | Current feedback hardware fault detected inside the drive; a hardware fault on the drive's control/power electronics that repair addresses. |
| E55 | Velocity error | Velocity error exceeded the configured limit. |
| E60 | Unknown axis | Illegal ID bits detected; a hardware fault inside the drive rather than in the wiring or application. |
| E61 / E62 | Aux feedback AQB / loss | Auxiliary encoder illegal transition, or auxiliary feedback wiring open / shorted / missing. |
| E63 / E64 | Feedback noise | Noise on the motor or auxiliary feedback signals. |
| E65 | Hookup fault | The hookup test failed: motor power / feedback wiring or feedback device. |
| E66 | Autotune fault | The autotune procedure failed. |
| E67 | Task init | Operating system failed to initialize; hardware failure if it persists after a power cycle. |
| E68 | SCANport comm | DPI / SCANport communication failed; check the device and cable. |
| E69 | Objects init | Non-volatile memory corrupt due to control-board hardware failure. |
| E70 | NV memory init | Non-volatile memory corrupt; load defaults and save. |
| E71 | Memory init | RAM or flash validation failure; if it persists through a power cycle, the fault is in the drive's control board. |
| E72 | Drive overtemperature | Inverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle. |
| E73 | Backplane comm | Power-rail CAN communication failed; check module seating and the power rail. |
| E74 | Bus overcurrent | DC link current exceeded rating; motor or transmission problem, or an undersized IAM. |
| E75 | Shunt time out | The IAM, AM or shunt module exceeded its shunt resistor continuous rating. |
| E76 | CAN init | DPI hardware initialization fault; control-board hardware failure. |
| E77 | Module mismatch | A 230V and a 460V module are mixed on the same power rail. |
| E78 | SERCOS init | Control hardware fault detected at SERCOS initialization. |
| E79 | Shunt module fault | The shunt module reports a temperature or shunt fault, or is missing from the power rail. |
| E80 | CPLD fault | Control hardware fault detected; a fault inside the drive's control electronics. |
| E81 | Common bus fault | Common-bus configuration fault. |
| E90 | Precharge timeout | Precharge did not complete in time. |
| E95 | IPIM fault | The Integrated Power Interface Module reported a fault. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 2094-UM001, Kinetix 6000 Multi-axis Servo Drives User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.
Find answers to shipping, warranties, repairs, and more.
Trademarks & Compatibility
All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.
Independent Supplier
NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.
Product Condition & Warranty
Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.
Firmware & Software Licensing
Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.
NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.
© 2026 NJT Automation. Independent industrial automation supplier and repair provider.