Allen-Bradley 2094-BC07-M05-M Kinetix 6000 Servo Drive
In stock: 2 units in Milwaukee, WI. Physically stocked and ready to ship or available for local pickup. Includes a 1-year full-function warranty.
Kinetix 6200 / 6500 400V-class IAM power module: 45 kW converter (68 A DC) with a 22.0 kW / 49 A (0-pk) inverter axis · power module for a Kinetix 6200 (sercos) or 6500 (EtherNet/IP) control module · double-wide

Actual NJT inventory photos
Price
$5,999.99USD
Used units available
| Part Number | 2094-BC07-M05-M |
| Description | Kinetix 6200 / 6500 IAM power module, 45 kW, 400V-class. In stock in used condition, Series A. |
| Shipping | Ships same or next business day UPS Ground included | Next-Day Air and Worldwide Shipping available at checkout |
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send us your defective 2094-BC07-M05-M after your purchase for a 10% core credit ($600). We also purchase old or damaged parts outright. |
Replacement Options for 2094-BC07-M05-M
Pick a condition and series below. UPS Ground shipping included.
| Variants | Part NumberConditionSeriesQtyPrice 2094-BC07-M05-M /A$5,999.99 Used · Series A · 2 in stock2094-BC07-M05-M /AUsedSeries A2$5,999.99 USD | ||||||
| Availability | 2 units in stock | ||||||
| Repairs | 2094-BC07-M05-M Mail-In Repair ServiceEstimated: $2,895.00 | ||||||
Part Number Decoder | Kinetix 6200 / 6500 IAM power module 2094BC07M05-Mwidth
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||
Series & Revisions | Series A in stock; other series on request. The -S (Kinetix 6000, SERCOS) and -M (Kinetix 6200 / 6500) suffixes are different control families and do not interchange on a rail. Series notes: Match the suffix. Within the same catalog number, flash the replacement to the firmware revision the Logix project expects before substituting. | ||||||
Intended Use | Designed for multi-axis coordinated servo motion applications. Kinetix 6000 integrated axis modules supply the DC bus and run the first axis for coordinated multi-axis machines: packaging, converting, printing, web handling, material handling and pick-and-place, with SERCOS or EtherNet/IP motion from a Logix controller. | ||||||
Migration Path | Rockwell Automation has discontinued the Kinetix 6000 (2094-xxxx-S) and published Kinetix 5700 as the successor for the whole 2094 family. Published successor for the Kinetix 6000 / 6200 / 6500: Kinetix 5700 (2198-P power supply, 2198-D dual-axis and 2198-S single-axis inverters).
A like-for-like replacement or a repair keeps the existing program, wiring and panel layout; a migration is a project. Both are listed on this page so the choice can be made on lead time and budget. | ||||||
Physical Data | Weight and DimensionsWeight22.0 lb (9.98 kg)
Product weight are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||
Similar Part Numbers |
| ||||||
| Category | Kinetix 6000 | ||||||
| UPC / GTIN | 0884951147805 | ||||||
| Part Number | 2094-BC07-M05-M | ||||||
| Manufacturer | Allen-Bradley | ||||||
Previously sold 2094-BC07-M05-M1 sold
NJT Automation has supplied and shipped one 2094-BC07-M05-M Kinetix 6200 / 6500 IAM power module in 2025; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 1 in 2025
- Series
- A × 1
Can the 2094-BC07-M05-M be repaired?
Yes. NJT Automation repairs the 2094-BC07-M05-M by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.
NJT managed repair. No evaluation fee; no repair, no charge. Prepaid UPS label both ways, $650 minimum, rush available. 1-year full-function warranty included, 2- and 3-year options.
Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Find a servo drive repair specialiston RepairMode.com ↗Common failures
Failure patterns we regularly see on Kinetix 6200 / 6500 IAM power module hardware like the 2094-BC07-M05-M:
- Current sensor (Hall-effect) drift or failure: torque ripple, motor hum at enable, or false overcurrent trips
- Bus undervoltage (E09) or bus overvoltage (E10): aged DC bus electrolytic capacitors, or regen energy the shunt cannot absorb
- Control module not recognized: bent or corroded pins on the interface connector between the IAM power module and its SE02F / EN02D control module
- Converter section failure: input rectifier or converter IGBT module blown after a line-side surge, missing phase, or a shorted axis downstream
- Cooling fan worn out: heatsink overtemperature trips and thermal stress on the power stage
Photos by NJT Automation; test videos from NJT or network repair technicians.
Still have questions?
Find answers to shipping, warranties, repairs, and more.