Allen-Bradley 20AD027C3AYNANC0 PowerFlex 70 Drive 20 Hp
Allen-Bradley 20AD027C3AYNANC0 PowerFlex 70 AC drive, 480V AC, 27 A / 20 Hp normal duty, Frame D: IP66 NEMA 4X, full-numeric LCD HIM, EMC filter, no comm adapter, Enhanced Control. NJT Automation offers mail-in repair for the 20AD027C3AYNANC0 with a 1-year warranty; replacement pricing is available on request.
Mail-in repair available now. Returned with a 1-year warranty. Replacement pricing on request.

Actual NJT inventory photos
| Part Number | 20AD027C3AYNANC0 |
| Price | On Request Previously sold for $3,699.99 USDAvailability and condition determine final quote. |
| Description | PowerFlex 70 Enhanced Control AC drive, 20 Hp, 480V AC. |
| Shipping | UPS Ground included | Next-Day Air and Worldwide Shipping available at checkout |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send us your defective 20AD027C3AYNANC0 after your purchase for a 10% core credit. We also purchase old or damaged parts outright. |
| Availability | Sourced on request We do not have a 20AD027C3AYNANC0 on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit. | ||||||||
| Sourcing | Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup. | ||||||||
| Repairs | 20AD027C3AYNANC0 Mail-In Repair ServiceEstimated: $1,850.00 | ||||||||
Part Number Decoder | PowerFlex 70 Enhanced Control AC drive 20AD027C3AYNANC0
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||
Intended Use | Intended for general-purpose machine-level variable-speed control applications. PowerFlex 70 drives run conveyors, pumps, fans, mixers and machine axes up to 50 Hp with sensorless vector control, optional encoder feedback and DPI communication adapters, in panels on packaging, material-handling and process equipment. Safe Torque Off lets the drive sit in the machine's safety circuit without an external contactor. | ||||||||
Physical Data | Weight and DimensionsWeight20.4 lb (9.25 kg)H × W × D13.8 × 8.7 × 7.1 in. (350 × 219.9 × 179.8 mm)
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||
Similar Part Numbers |
| ||||||||
Allen Bradley Information | Technical SpecificationsLifecycle status
| ||||||||
| Category | PowerFlex 70 | ||||||||
| Part Number | 20AD027C3AYNANC0 | ||||||||
| Manufacturer | Allen-Bradley | ||||||||
Previously sold 20AD027C3AYNANC0
1 soldNJT Automation has supplied and shipped one 20AD027C3AYNANC0 PowerFlex 70 Enhanced Control AC drive in 2025; request a quote and we will source another from our supplier network.
- Sold
- 1 in 2025
Can the 20AD027C3AYNANC0 be repaired?
Yes. NJT Automation repairs the 20AD027C3AYNANC0 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.
NJT managed repair. No evaluation fee; no repair, no charge. Prepaid UPS label both ways, $650 minimum, rush available. 1-year full-function warranty included, 2- and 3-year options.
Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Find a VFD repair specialiston RepairMode.com ↗Common failures
Failure patterns we regularly see on PowerFlex 70 Enhanced Control AC drive hardware like the 20AD027C3AYNANC0:
- DC bus capacitor aging: undervoltage trips (F4) or a drive that will not finish precharge
- Precharge relay / circuit failure leaving the drive stuck in precharge
- Hardware overcurrent (F12) or ground fault (F13) from a failed power stage after a motor or cable short
- Heatsink overtemperature (F8) from a failed fan or blocked airflow
- Control board failure: no display, no response or a HIM that never connects
Photos by NJT Automation; test videos from NJT or network repair technicians.
Still have questions?