NJT Automation has supplied and shipped 3 25B-D043N114 PowerFlex 525 AC drives in 2026; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 3 in 2026
- Series
- A × 3
In stock: 1 unit in Milwaukee, WI.
PowerFlex 525 AC drive · 480V AC 3-ph · 43 A / 30 Hp normal duty (25 Hp heavy duty) · Frame E · IP20 open

Actual NJT inventory photos
Price
$1,749.99USDUsedView listing
| Part Number | 25B-D043N114 |
| Description | PowerFlex 525 AC drive, 30 Hp, 480V AC. In stock in used condition. |
| Shipping | Ships same or next business day
|
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 25B-D043N114 for a 10% core credit. |
| Variants | Part NumberConditionSeriesQtyPrice 25B-D043N114$1,749.99 Used · 1 in stock25B-D043N114Used—1$1,749.99 USD | ||||||||
| Availability | 1 Unit in StockIndependently SourcedNot an OEM-Authorized Distributor | ||||||||
| Repairs | 25B-D043N114 Mail-In Repair ServiceEstimated: $1,440.00 | ||||||||
Part Number Decoder | PowerFlex 525 AC drive 25B·D·043·N·1·1·4
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||
Series & Revisions | No series in stock today; request a series above. | ||||||||
Intended Use | Designed for EtherNet/IP-connected general-purpose variable-speed control applications. PowerFlex 525 drives run conveyors, pumps, fans, mixers and small machines up to 30 Hp, with embedded EtherNet/IP, Safe Torque Off and a removable control module, under a Logix or Micro800 controller. Safe Torque Off lets the drive sit in the machine's safety circuit without an external contactor. | ||||||||
Physical Data | Weight and DimensionsWeight28.4 lb (12.9 kg)H × W × D11.8 × 7.3 × 11 in. (300 × 185 × 279 mm)▾
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||
Similar Part Numbers |
| ||||||||
| Category | PowerFlex 525 | ||||||||
| UPC / GTIN | 884951886094 | ||||||||
| Part Number | 25B-D043N114 | ||||||||
| Manufacturer | Allen-Bradley | ||||||||
NJT Automation has supplied and shipped 3 25B-D043N114 PowerFlex 525 AC drives in 2026; these listings are sold and the in-stock options above are ready to ship.
Yes. NJT Automation repairs the 25B-D043N114 by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Failure patterns we regularly see on PowerFlex 525 AC drive hardware like the 25B-D043N114:
Fault code reference
43 codes · 520-UM001
Fault codes a PowerFlex 525 AC drive reports on the drive's integral keypad display (F followed by the fault number), as documented in Rockwell Automation publication 520-UM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
| Code | Fault | What it indicates |
|---|---|---|
| F002 | Auxiliary Input | The auxiliary input interlock is open. |
| F003 | Power Loss | Excessive DC bus voltage ripple: incoming phase loss, line imbalance or a blown input fuse. |
| F004 | UnderVoltage | DC bus voltage fell below the minimum value: low or interrupted incoming line. |
| F005 | OverVoltage | DC bus voltage exceeded the maximum value: high line, transients or regenerative load with too short a decel time. |
| F006 | Motor Stalled | The drive is unable to accelerate or decelerate the motor. |
| F007 | Motor Overload | Internal electronic motor overload trip. |
| F008 | Heatsink OvrTmp | Heatsink temperature exceeded the limit: blocked or dirty fins, high ambient or a failed fan. |
| F009 | CC OvrTmp | Control module temperature exceeded the limit. |
| F012 | HW OverCurrent | Output current exceeded the hardware current limit: shorted or grounded motor leads, or a failed power stage. |
| F013 | Ground Fault | A current path to earth ground was detected at one or more output terminals. |
| F015 | Load Loss | Output torque current fell below the programmed load-loss level. |
| F021 | Output Ph Loss | Output phase loss detected (when enabled). |
| F029 | Analog In Loss | An analog input configured to fault on signal loss has lost its signal. |
| F033 | Auto Rstrt Tries | The drive used all programmed auto-restart attempts without clearing the fault. |
| F038 / F039 / F040 | Phase U / V / W to Gnd | A phase-to-ground fault was detected between the drive and motor in that phase. |
| F041 / F042 / F043 | Phase UV / UW / VW Short | Excessive current was detected between two output terminals. |
| F048 | Params Defaulted | The drive was commanded to write default values to EEPROM. |
| F059 | Safety Open | Both safety inputs (Safety 1, Safety 2) are not enabled. |
| F063 | SW OverCurrent | The programmed software current trip level was exceeded. |
| F064 | Drive Overload | The drive rating of 150% for 1 minute or 200% for 3 seconds was exceeded. |
| F070 | Power Unit | A failure was detected in the drive power section. |
| F071 | DSI Net Loss | The DSI communication network faulted. |
| F072 | Opt Net Loss | The option-card network faulted. |
| F073 | EN Net Loss | Control through the embedded EtherNet/IP adapter was interrupted. |
| F080 | Autotune Failure | The autotune function was cancelled or failed. |
| F081 | DSI Comm Loss | The RS-485 (DSI) port stopped communicating. |
| F082 | Opt Comm Loss | Communication with the option card was lost. |
| F083 | EN Comm Loss | Communication with the embedded EtherNet/IP adapter was lost. |
| F091 | Encoder Loss | Encoder feedback was lost (encoder option card). |
| F094 | Function Loss | The function-loss input is open. |
| F100 | Parameter Chksum | The parameter checksum does not match: reset to defaults and reprogram. |
| F101 | External Storage | External (keypad / USB) storage read or write failed. |
| F105 | C Connect Err | The control module was disconnected from the power module while powered. |
| F106 | Incompat C-P | The control module firmware is incompatible with the power module. |
| F107 | Replaced C-P | The control module was moved to a different power module; parameters were defaulted. |
| F109 | Mismatch C-P | The control module and power module ratings do not match. |
| F110 | Keypad Membrane | The keypad membrane failed or a key is stuck. |
| F111 | Safety Hardware | The safety input hardware failed. |
| F114 | uC Failure | Microcontroller failure. |
| F122 | I/O Board Fail | A failure was detected in the drive control and I/O section. |
| F125 | Flash Update Req | A firmware flash update is required. |
| F126 | NonRecoverablErr | A non-recoverable error occurred. |
| F127 | DSIFlashUpdatReq | A DSI firmware flash update is required. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 520-UM001, PowerFlex 520-Series Adjustable Frequency AC Drive User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.
Find answers to shipping, warranties, repairs, and more.
Trademarks & Compatibility
All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.
Independent Supplier
NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.
Product Condition & Warranty
Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.
Firmware & Software Licensing
Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.
NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.
© 2026 NJT Automation. Independent industrial automation supplier and repair provider.