NJT Automation has supplied and shipped 4 2711P-T19C22D9P PanelView Plus 7 Performance touch terminals since 2025; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 4 since 2025
- Series
- B × 3, A × 1
In stock: 5 units in Milwaukee, WI.
PanelView Plus 7 Performance 19-in. color TFT touch terminal · dual Ethernet ports (DLR) · 24V DC powered

Actual NJT inventory photos
| Part Number | 2711P-T19C22D9P |
| Description | PanelView Plus 7 Performance touch terminal, 19-in. Touch, 24V DC. In stock in used condition, Series B. |
| Shipping | Ships same or next business day
|
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 2711P-T19C22D9P for a 10% core credit. |
| Variants | Part NumberConditionSeriesQtyPrice 2711P-T19C22D9P /B$2,999.99 Used · Series B · 1 in stock2711P-T19C22D9P /BUsedSeries B1$2,999.99 USD 2711P-T19C22D9P /B$2,999.99 Used · Series B · 2 in stock2711P-T19C22D9P /BUsedSeries B2$2,999.99 USD 2711P-T19C22D9P/B$3,499.99 Refurbished · Series B · 2 in stock2711P-T19C22D9P/BRefurbishedSeries B2$3,499.99 USD | ||||||||||||||||||||||
| Availability | 5 Units in StockIndependently SourcedNot an OEM-Authorized Distributor | ||||||||||||||||||||||
| Repairs | 2711P-T19C22D9P Mail-In Repair ServiceEstimated: $1,350.00 | ||||||||||||||||||||||
Part Number Decoder | PanelView Plus 7 Performance touch terminal 2711P·T·19·C·22·D·9·P
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||||||||||||||||
Series & Revisions | Series B in stock; other series on request. Series A: Windows CE 6.0, 512 MB RAM, firmware up to v12. Series B: Windows 10 IoT Core, 4 GB RAM, firmware v12 and later; no Windows desktop or Remote Desktop client (VNC remote access remains). AC-powered models exist as Series A only; Series B is 24V DC. Series notes: Series B terminals may replace Series A terminals in compatible applications, but differences in operating systems, firmware, and supported features must be evaluated before replacement. Existing FactoryTalk View ME applications may require updates or modifications. A Series A can stand in for a Series B only if the runtime is saved for ME v12; its firmware stops there, so a project saved in ME v13 or later will not load. | ||||||||||||||||||||||
Intended Use | Designed for machine operator interface (HMI) applications. PanelView Plus 7 terminals with a 19-in. display give operators graphics, alarms and trends for packaging, food and beverage, pharmaceutical, automotive and water applications, communicating with Logix controllers over EtherNet/IP and running FactoryTalk View ME applications. | ||||||||||||||||||||||
Physical Data | Weight and DimensionsWeight12.4 lb (5.62 kg)H × W × D16.2 × 19.1 × 2.7 in. (411 × 485 × 69.6 mm)▾
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||||||||||||||||
Similar Part Numbers |
| ||||||||||||||||||||||
Allen-Bradley Information | Technical Specifications11 parameters from manufacturer-published specifications▾
Typical manufacturer-published values for this catalog number; confirm against the current manufacturer documentation before specifying. | ||||||||||||||||||||||
| Category | PanelView Plus | ||||||||||||||||||||||
| UPC / GTIN | 885630844756 | ||||||||||||||||||||||
| Part Number | 2711P-T19C22D9P | ||||||||||||||||||||||
| Manufacturer | Allen-Bradley | ||||||||||||||||||||||
NJT Automation has supplied and shipped 4 2711P-T19C22D9P PanelView Plus 7 Performance touch terminals since 2025; these listings are sold and the in-stock options above are ready to ship.
Yes. NJT Automation repairs the 2711P-T19C22D9P by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Failure patterns we regularly see on PanelView Plus 7 Performance touch terminal hardware like the 2711P-T19C22D9P:
Fault code reference
6 codes · 2711P-UM008
Fault codes a PanelView Plus 7 Performance touch terminal reports on the start-up screen (shown as Fatal followed by a two-character code) and the ERR (red) and STS (green) indicators on the back of the terminal, as documented in Rockwell Automation publication 2711P-UM008. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
| Code | Failure | What it indicates |
|---|---|---|
| Fatal 02 | Watchdog error | A watchdog reset occurred. By default the terminal shows the error at start-up and halts at the maintenance window instead of booting the application; monitor for recurrence. |
| Fatal 3A | Stuck touch | The start-up self-test found a touch cell held or stuck. Make sure nothing is pressing on the screen (including a damaged anti-glare overlay) and reset the terminal without touching it; if it persists, the fault is in the touch screen / display assembly. |
Fatal 02 is documented in 2711P-UM007 / UM008; Fatal 3A on PanelView Plus 7 is documented in the Rockwell Knowledgebase article "PanelView Plus Fatal 3A at Boot up", which covers all PanelView Plus, Plus 6 and Plus 7 touch models.
| Indicators | State | What it indicates |
|---|---|---|
| ERR blinking · STS off | Recoverable firmware error / configuration failure | Reload the firmware or restore the terminal to its factory default image. |
| ERR on · STS on | Fatal hardware error | A hardware fault inside the terminal that a reset or firmware reload will not clear. |
| ERR on · STS blinking | Fatal display hardware error | A hardware fault in the terminal's display section that a reset or firmware reload will not clear. |
| ERR off · STS off | No power | Indicators flash at start-up and STS stays on after a successful boot; if both stay off, check the power cable and supply. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 2711P-UM008, PanelView Plus 7 Performance Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.
Find answers to shipping, warranties, repairs, and more.
Trademarks & Compatibility
All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.
Independent Supplier
NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.
Product Condition & Warranty
Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.
Firmware & Software Licensing
Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.
NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.