Allen-Bradley 2711P-RP2A PanelView Plus 128 MB
Allen-Bradley 2711P-RP2A PanelView Plus logic module for 700…1500 terminals, 128 MB flash / 128 MB RAM, AC powered. NJT Automation sources the 2711P-RP2A on request; send the part number for a replacement or repair quote.
Quote required. Request a quote below for pricing and delivery.

Actual NJT inventory photos
| Part Number | 2711P-RP2A |
| Price | On Request Previously sold for $299.99 - $2,299.99 USDAvailability and condition determine final quote. |
| Description | PanelView Plus logic module, 128 MB. |
| Shipping |
|
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 2711P-RP2A for a 10% core credit. |
| Availability | Sourced on RequestIndependently SourcedNot an OEM-Authorized Distributor We do not have a 2711P-RP2A on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit. | ||||||||||||||
| Sourcing | Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup. | ||||||||||||||
| Repairs | 2711P-RP2A Mail-In Repair Service | ||||||||||||||
Part Number Decoder | PanelView Plus logic module 2711PRP2A
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||||||||
Intended Use | Intended for machine operator interface (HMI) applications. The logic module is the computer behind a PanelView Plus terminal, running the FactoryTalk View ME application that operators use to monitor and run packaging, process and assembly equipment. | ||||||||||||||
Physical Data | Weight and DimensionsBox12 × 10 × 8 in.
Shipping box and weight are recorded from previous shipments of this catalog number and are provided for freight planning. | ||||||||||||||
Similar Part Numbers |
| ||||||||||||||
Allen-Bradley Information | Technical Specifications7 parameters from manufacturer-published specifications
Typical manufacturer-published values for this catalog number; confirm against the current manufacturer documentation before specifying. | ||||||||||||||
| Category | PanelView Plus | ||||||||||||||
| Part Number | 2711P-RP2A | ||||||||||||||
| Manufacturer | Allen-Bradley | ||||||||||||||
Previously sold 2711P-RP2A
5 soldNJT Automation has supplied and shipped 5 2711P-RP2A PanelView Plus logic modules since 2024; request a quote and we will source another from our supplier network.
- Sold
- 5 since 2024
Can the 2711P-RP2A be repaired?
Yes. NJT Automation repairs the 2711P-RP2A by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
- Evaluation
- Free evaluation.
- Shipping
- Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
- Pricing
- $650 minimum for successful repairs.
- Warranty
- 1-year full-function warranty included. 2- and 3-year options available.
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Common Failures
Failure patterns we regularly see on PanelView Plus logic module hardware like the 2711P-RP2A:
- Real-time clock resetting at each power cycle: depleted 2711P-RY2032 coin cell
- Ethernet port dead or dropping the PLC connection: damaged magnetics or PHY after a ground-loop or surge
- CompactFlash slot no longer detecting the card, or repeated CF corruption from a marginal 3.3V rail
- No power LED on 24V DC input: blown input fuse, shorted input protection or a dead DC-DC converter
- Random resets or lockups under load: failed electrolytic capacitors on the power supply section of the logic board
Fault code reference
2711P-RP2A Fault Codes
20 codes · 2711P-UM001
Fault codes a PanelView Plus logic module reports on the screen at start-up (error number with an ERROR! message) and the Fault (red) and Comm (green) indicators, as documented in Rockwell Automation publication 2711P-UM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
Start-up error messages
| Error # | Displayed message | What it indicates |
|---|---|---|
| 1 | RAM Test | RAM test failure. Reset the terminal; if it persists, reseat the SO-DIMM (700…1500). A persistent failure is a logic board fault. |
| 14 | RAM Header Check | The OS firmware being downloaded is not compatible with the hardware (400/600 terminals). |
| 20 | Transfer Image | Programming the downloaded OS firmware into flash failed (400/600 terminals). |
| 23 | Download Task / Internal CF | Firmware image too large (400/600), or an error programming firmware to the internal CompactFlash (700…1500). |
| 24 | CRC Check | Checksum of the OS firmware failed; reload firmware. Persistent failures point to the internal CompactFlash or logic module. |
| 25 | Invalid Prod Family | The OS firmware being downloaded is not for this terminal family (400/600 terminals). |
| 27 | Decompress System | Error decompressing the OS firmware from flash to RAM (400/600 terminals). |
| 30 | Watchdog Test | Watchdog test failure; reload firmware, then suspect the logic module. |
| 31 | Stuck Key | A function key is held or stuck. Make sure nothing presses on the keypad (on the 400/600, tap F1 rather than holding it to enter Configuration mode) and reset; persistent failures mean the keypad / display module. |
| 31.5 | Stuck Touch | Touch screen reports a constant touch (700…1500 terminals). Remove anything pressing on the screen, including a damaged anti-glare overlay, and reset; persistent failures mean the display module. |
Show 5 more codes
| 32 | Battery Test | Battery failure (700…1500 terminals). Fit a new battery; if it persists, the fault is on the logic module. |
| 33.5 | NVRAM Access | Nonvolatile memory failure (700…1500 terminals); upgrade system firmware to 3.10.03 or later. |
| 3a | Stuck Touch | Touch screen reports a constant touch (400/600 terminals). Remove anything pressing on the screen, including a damaged anti-glare overlay, and reset; persistent failures mean the terminal. |
| 40 | EXE Check | System OS firmware is missing or corrupt; reload firmware. |
| 50 | External CF | Error loading OS firmware from the external CompactFlash card. |
Status indicator states if the terminal stops during start-up
| Indicators | State | What it indicates |
|---|---|---|
| Fault blinking · Comm off | Last firmware download failed | Recoverable: reload the firmware with the Firmware Upgrade Wizard. |
| Fault blinking · Comm blinking | Boot loader firmware failed or missing | Recoverable: reload the firmware with the Firmware Upgrade Wizard. |
| Fault blinking · Comm on | Windows CE OS firmware failed or missing | Recoverable: reload the firmware with the Firmware Upgrade Wizard. |
| Fault on · Comm off | Fatal hardware error | Hardware fault in the logic module (700…1500) or the terminal's logic board (400/600). |
| Fault on · Comm blinking | Fatal hardware error in display | Hardware fault in the display module (700…1500) or the terminal's display section (400/600). |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 2711P-UM001, PanelView Plus Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.
Still have questions?
Find answers to shipping, warranties, repairs, and more.