Allen-Bradley 2711P-RP8A PanelView Plus 6 512 MB
Allen-Bradley 2711P-RP8A PanelView Plus 6 logic module for 700…1500 terminals, 512 MB RAM, Windows CE 6.0 standard features, AC powered. NJT Automation sources the 2711P-RP8A on request; send the part number for a replacement or repair quote.
Quote required. Request a quote below for pricing and delivery.

Actual NJT inventory photos
| Part Number | 2711P-RP8A |
| Price | On Request Previously sold for $459.99 - $759.99 USDAvailability and condition determine final quote. |
| Description | PanelView Plus 6 logic module, 512 MB. |
| Shipping |
|
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 2711P-RP8A for a 10% core credit. |
| Availability | Sourced on RequestIndependently SourcedNot an OEM-Authorized Distributor We do not have a 2711P-RP8A on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit. | ||||||||||||
| Sourcing | Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup. | ||||||||||||
| Repairs | 2711P-RP8A Mail-In Repair Service | ||||||||||||
Part Number Decoder | PanelView Plus 6 logic module 2711PRP8A
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||||||
Series & Revisions | No series in stock today; request a series above. | ||||||||||||
Intended Use | Intended for machine operator interface (HMI) applications. The logic module is the computer behind a PanelView Plus terminal, running the FactoryTalk View ME application that operators use to monitor and run packaging, process and assembly equipment. | ||||||||||||
Physical Data | Weight and DimensionsBox12 × 10 × 8 in.
Shipping box and weight are recorded from previous shipments of this catalog number and are provided for freight planning. | ||||||||||||
Similar Part Numbers |
| ||||||||||||
Allen-Bradley Information | Technical Specifications6 parameters from manufacturer-published specifications
Typical manufacturer-published values for this catalog number; confirm against the current manufacturer documentation before specifying. | ||||||||||||
| Category | PanelView Plus | ||||||||||||
| Part Number | 2711P-RP8A | ||||||||||||
| Manufacturer | Allen-Bradley | ||||||||||||
Previously sold 2711P-RP8A
7 soldNJT Automation has supplied and shipped 7 2711P-RP8A PanelView Plus 6 logic modules since 2025; request a quote and we will source another from our supplier network.
- Sold
- 7 since 2025
- Series
- B × 4, A × 3
Can the 2711P-RP8A be repaired?
Yes. NJT Automation repairs the 2711P-RP8A by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
- Evaluation
- Free evaluation.
- Shipping
- Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
- Pricing
- $650 minimum for successful repairs.
- Warranty
- 1-year full-function warranty included. 2- and 3-year options available.
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Common Failures
Failure patterns we regularly see on PanelView Plus 6 logic module hardware like the 2711P-RP8A:
- Communication module slot not recognizing a 2711P-RN card
- Overheating in a sealed enclosure: thermal shutdown, then capacitor and solder-joint fatigue
- Will not boot or hangs on the splash screen: control board DRAM, flash or firmware failure
- Random resets or lockups under load: failed electrolytic capacitors on the power supply section of the logic board
- No power LED on 24V DC input: blown input fuse, shorted input protection or a dead DC-DC converter
Fault code reference
2711P-RP8A Fault Codes
19 codes · 2711P-UM006
Fault codes a PanelView Plus 6 logic module reports on the start-up splash screen (shown as Fatal followed by a two-character code, for example Fatal 3A) and the Fault (red) and Comm (green) indicators, as documented in Rockwell Automation publication 2711P-UM006. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
Fatal start-up codes
| Code | Failure | What it indicates |
|---|---|---|
| Fatal 02 | Watch dog reset | A momentary loss of control due to a software failure. The terminal halts at the maintenance window; monitor for recurrence. |
| Fatal 03 | Failed RAM | POST failure in the terminal's RAM; a hardware fault in the logic module (700…1500) or the terminal's logic board (400/600). |
| Fatal 0F | Firmware update failure | Fatal during firmware loading. Reset from the maintenance menu, restore factory defaults or reinstall firmware. |
| Fatal 1E | Firmware validation (CRC/format) failure | Fatal during firmware loading (1E also appears as a normal 'Update' progress code). Reset, restore defaults or reinstall firmware. |
| Fatal 1F | Firmware compatibility index failure | Firmware failed to validate the compatibility index of a firmware region; reinstall the correct firmware. |
| Fatal 31 | Stuck key | POST found a function key held or stuck. Make sure nothing presses on the keypad and reset the terminal without touching any key; if it persists, the fault is in the keypad / display module. |
| Fatal 3A | Stuck touch | POST found a touch cell held or stuck. Make sure nothing is pressing on the screen (including a damaged anti-glare overlay), then reset without touching it; if it persists, the fault is in the touch screen / display module. |
| Fatal 3B | Failed backlight | POST could not start the backlight; a hardware fault in the display module. If 3A or 3B appears right after an LED-backlit (newer series) display module was fitted to an older logic module, check the logic module firmware first (2711P-IN030 requires 7.00.20 or later for LED displays on Plus 6). |
| Fatal A5 | Firmware write to storage failure | Fatal during firmware loading (A5 also appears as a normal 'Update/Restore' progress code). Reset, restore defaults or reinstall firmware. |
| Fatal D2 | Firmware stored image verification failure | Fatal during firmware loading; reset, restore defaults or reinstall firmware. |
Show 6 more codes
| Fatal FF | Invalid or missing OS firmware image | No valid operating system image (FF also appears as a normal 'AutoTest' progress code). Reinstall firmware. |
| Fatal R0 | Failed to initialize restore operation | Fatal during a restore; reset the terminal from the maintenance menu. |
| Fatal R1 | Invalid header in .pvb file | Fatal during a restore; the backup file header is invalid. |
| Fatal R2 | Invalid header | Fatal during a restore. |
| Fatal R3 | Cannot write intermediate files | Fatal during a restore; the terminal could not write intermediate files. |
| Fatal R4 | Corrupt .pvb file | Fatal during a restore; the backup file is corrupt. |
The splash screen shows the state word and the code together, for example "Fatal 3A". Codes shown with the state AutoTest, Boot, Init, Update or Restore (E6, FF, G0, H1–JA, K1–MA, 1E, A5, DC) are normal progress messages; only codes shown with the state Fatal are errors. Rockwell Knowledgebase 459615 reproduces this list.
Status indicator states if the terminal stops during start-up
| Indicators | State | What it indicates |
|---|---|---|
| Fault blinking · Comm off | Recoverable firmware error | Last firmware download failed. Reload the firmware with the Firmware Upgrade Wizard. |
| Fault on · Comm off | Non-recoverable logic module fault | Hardware fault in the logic module (700…1500) or the terminal's logic board (400/600); not recoverable by a reset or firmware reload. |
| Fault on · Comm blinking | Non-recoverable display module fault | Hardware fault in the display module (700…1500) or the terminal's display section (400/600); not recoverable by a reset or firmware reload. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 2711P-UM006, PanelView Plus 6 Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.
Still have questions?
Find answers to shipping, warranties, repairs, and more.