View Cart

Allen-Bradley 2711P-RP8DK PanelView Plus 6 512 MB, 24V DC

In stock: 2 units in Milwaukee, WI.

PanelView Plus 6 logic module for 700…1500 terminals · 512 MB RAM · Windows CE 6.0 standard features · DC powered · conformal coated

Starting at

$3,499.99USDUnused surplus (open box), Series BView listing

Unused surplus units available below

Request Repair QuoteEstimated $1,295.00
Part Number2711P-RP8DK
DescriptionPanelView Plus 6 logic module, 512 MB, 24V DC. In stock in unused surplus condition, Series A and B.
Shipping
Ships same or next business day
UPS Ground
Included. Next-Day Air and worldwide shipping available.
Courier
Within 350 miles, est. $3.50/mile, subject to availability.
Pickup
Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954.
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price (from $525.00)
3 years
+25% of product price (from $875.00)
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send in your defective 2711P-RP8DK for a 10% core credit.

Replacement 2711P-RP8DK Options

Allen-Bradley 2711P-RP8DK PanelView Plus Logic Module Conformal Coated

$3,499.99 USDIn-stock match

Condition: Unused surplus (open box)

Series B

1 in stockView details

Allen-Bradley 2711P-RP8DK PanelView Plus Logic Module - Without Box

$4,199.99 USDIn-stock match

Condition: Unused surplus (open box)

Series A

1 in stockView details
Variants
Part NumberConditionSeriesQtyPrice
2711P-RP8DK /B$3,499.99
Unused surplus (open box) · Series B · 1 in stock
2711P-RP8DK /BUnused surplus (open box)Series B1$3,499.99 USD
2711P-RP8DK /A$4,199.99
Unused surplus (open box) · Series A · 1 in stock
2711P-RP8DK /AUnused surplus (open box)Series A1$4,199.99 USD

2711P-RP8DK

Refurbished — pick series, then request a quote

Request Quote
2711P-RP8DKRefurbished—Request Quote
Availability
2 Units in StockIndependently SourcedNot an OEM-Authorized Distributor
Repairs

2711P-RP8DK Mail-In Repair Service

Estimated: $1,295.00

Part Number Decoder

PanelView Plus 6 logic module
2711PRP8DK
2711P
BulletinPanelView Plus: Allen-Bradley's FactoryTalk View Machine Edition HMI terminal family (PanelView Plus, Plus CE, Plus 6 and Plus 7).
RP
Module typeReplacement logic module: the processor/memory unit that attaches to the rear of a 700…1500 display module.
8
Platform / memoryPanelView Plus 6, 512 MB RAM, Windows CE 6.0 standard features.
D
Power input24V DC power input.
K
CoatingConformal coated.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Series & Revisions

Series A and B in stock; other series on request.

Intended Use

Intended for machine operator interface (HMI) applications. The logic module is the computer behind a PanelView Plus terminal, running the FactoryTalk View ME application that operators use to monitor and run packaging, process and assembly equipment. Conformal coating suits corrosive or high-humidity atmospheres (ANSI/ISA 71.04 G3), such as pulp and paper, wastewater, chemical and coastal sites.

Physical Data

Weight and DimensionsBox12 × 10 × 8 in.
Shipping Box (L × W × H)12 × 10 × 8 in. (305 × 254 × 203 mm)
Most common box recorded for this catalog number
Shipping box and weight are recorded from previous shipments of this catalog number and are provided for freight planning.
CategoryPanelView Plus
UPC / GTIN612598876891
Part Number2711P-RP8DK
ManufacturerAllen-Bradley

2711P-RP8DK Sales History

1 sold

NJT Automation has supplied and shipped one 2711P-RP8DK PanelView Plus 6 logic module in 2025; these listings are sold and the in-stock options above are ready to ship.

Sold
1 in 2025
Series
A × 1
Allen-Bradley 2711P-RP8DK Used - previously sold by NJT AutomationSold

Allen-Bradley 2711P-RP8DK PanelView Plus Logic Module

$1,199.99 USD

Used

Request Quote

Can the 2711P-RP8DK be repaired?

Yes. NJT Automation repairs the 2711P-RP8DK by mail-in: diagnostic evaluation, component-level repair and a functional test.

Option 1

NJT Managed Repair

Evaluation
Free evaluation.
Shipping
Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
Pricing
$650 minimum for successful repairs.
Warranty
1-year full-function warranty included. 2- and 3-year options available.
Get a repair quoteOr text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

Find an HMI repair specialiston RepairMode.com ↗

Common Failures

Failure patterns we regularly see on PanelView Plus 6 logic module hardware like the 2711P-RP8DK:

  • No power LED on 24V DC input: blown input fuse, shorted input protection or a dead DC-DC converter
  • Overheating in a sealed enclosure: thermal shutdown, then capacitor and solder-joint fatigue
  • RS-232 port dead after a hot-plugged cable: blown line driver IC on the control board
  • CompactFlash slot no longer detecting the card, or repeated CF corruption from a marginal 3.3V rail
  • Will not boot or hangs on the splash screen: control board DRAM, flash or firmware failure

Fault code reference

2711P-RP8DK Fault Codes

19 codes · 2711P-UM006View codesHide codes

Fault codes a PanelView Plus 6 logic module reports on the start-up splash screen (shown as Fatal followed by a two-character code, for example Fatal 3A) and the Fault (red) and Comm (green) indicators, as documented in Rockwell Automation publication 2711P-UM006. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

Fatal start-up codes

2711P-RP8DK Fatal start-up codes
CodeFailureWhat it indicates
Fatal 02Watch dog resetA momentary loss of control due to a software failure. The terminal halts at the maintenance window; monitor for recurrence.
Fatal 03Failed RAMPOST failure in the terminal's RAM; a hardware fault in the logic module (700…1500) or the terminal's logic board (400/600).
Fatal 0FFirmware update failureFatal during firmware loading. Reset from the maintenance menu, restore factory defaults or reinstall firmware.
Fatal 1EFirmware validation (CRC/format) failureFatal during firmware loading (1E also appears as a normal 'Update' progress code). Reset, restore defaults or reinstall firmware.
Fatal 1FFirmware compatibility index failureFirmware failed to validate the compatibility index of a firmware region; reinstall the correct firmware.
Fatal 31Stuck keyPOST found a function key held or stuck. Make sure nothing presses on the keypad and reset the terminal without touching any key; if it persists, the fault is in the keypad / display module.
Fatal 3AStuck touchPOST found a touch cell held or stuck. Make sure nothing is pressing on the screen (including a damaged anti-glare overlay), then reset without touching it; if it persists, the fault is in the touch screen / display module.
Fatal 3BFailed backlightPOST could not start the backlight; a hardware fault in the display module. If 3A or 3B appears right after an LED-backlit (newer series) display module was fitted to an older logic module, check the logic module firmware first (2711P-IN030 requires 7.00.20 or later for LED displays on Plus 6).
Fatal A5Firmware write to storage failureFatal during firmware loading (A5 also appears as a normal 'Update/Restore' progress code). Reset, restore defaults or reinstall firmware.
Fatal D2Firmware stored image verification failureFatal during firmware loading; reset, restore defaults or reinstall firmware.
Fatal FFInvalid or missing OS firmware imageNo valid operating system image (FF also appears as a normal 'AutoTest' progress code). Reinstall firmware.
Fatal R0Failed to initialize restore operationFatal during a restore; reset the terminal from the maintenance menu.
Fatal R1Invalid header in .pvb fileFatal during a restore; the backup file header is invalid.
Fatal R2Invalid headerFatal during a restore.
Fatal R3Cannot write intermediate filesFatal during a restore; the terminal could not write intermediate files.
Fatal R4Corrupt .pvb fileFatal during a restore; the backup file is corrupt.

The splash screen shows the state word and the code together, for example "Fatal 3A". Codes shown with the state AutoTest, Boot, Init, Update or Restore (E6, FF, G0, H1–JA, K1–MA, 1E, A5, DC) are normal progress messages; only codes shown with the state Fatal are errors. Rockwell Knowledgebase 459615 reproduces this list.

Status indicator states if the terminal stops during start-up

2711P-RP8DK Status indicator states if the terminal stops during start-up
IndicatorsStateWhat it indicates
Fault blinking · Comm offRecoverable firmware errorLast firmware download failed. Reload the firmware with the Firmware Upgrade Wizard.
Fault on · Comm offNon-recoverable logic module faultHardware fault in the logic module (700…1500) or the terminal's logic board (400/600); not recoverable by a reset or firmware reload.
Fault on · Comm blinkingNon-recoverable display module faultHardware fault in the display module (700…1500) or the terminal's display section (400/600); not recoverable by a reset or firmware reload.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 2711P-UM006, PanelView Plus 6 Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 2711P-RP8DK is a PanelView Plus 6 logic module for 700…1500 terminals, 512 MB RAM, Windows CE 6.0 standard features, DC powered, conformal coated.
NJT Automation currently has 2 units of the 2711P-RP8DK in stock in unused surplus condition (Series A and B). Each listing states its own condition and series. Never put into service, but the original packaging has been opened or replaced, so it is classed as used rather than new. The module itself has no meaningful run time.
2 units of the 2711P-RP8DK PanelView Plus 6 logic module are on the shelf in Milwaukee, WI, priced from $3,499.99. Orders before 5:00 PM Central on a business day ship the same day; next-day air is available at checkout.
24V DC power input.
PanelView Plus 6, 512 MB RAM, Windows CE 6.0 standard features.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.