View Cart

Allen-Bradley 2711P-T7C22A9P PanelView Plus 7 – Repair Service Available

Allen-Bradley 2711P-T7C22A9P PanelView Plus 7 Performance 6.5-in. color TFT touch terminal, dual Ethernet ports (DLR), AC powered. NJT Automation offers mail-in repair for the 2711P-T7C22A9P with a 1-year warranty; replacement pricing is available on request.

Mail-in repair available now. Returned with a 1-year warranty. Replacement pricing on request.

Request Replacement QuoteRequest Repair QuoteEstimated $1,295.00
Part Number2711P-T7C22A9P
Price
On Request
Previously sold for $1,999.99 - $4,599.99 USDAvailability and condition determine final quote.
DescriptionPanelView Plus 7 Performance touch terminal, 6.5-in. Touch, 240V AC.
Shipping
UPS Ground
Free
Expedited
Next-Day Air and worldwide shipping available
Courier
Within 350 miles · est. $3.50/mile, subject to availability
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price ($300.00)
3 years
+25% of product price ($500.00)
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send in your defective 2711P-T7C22A9P for a 10% core credit.

Availability
Sourced on RequestNot an OEM-Authorized Distributor

We do not have a 2711P-T7C22A9P on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit.

Sourcing

Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup.

Request QuoteHow Level 1 sourcing works
Repairs

2711P-T7C22A9P Mail-In Repair Service

Estimated: $1,295.00

Part Number Decoder

PanelView Plus 7 Performance touch terminal
2711PT7C22A9P
2711P
BulletinPanelView Plus: Allen-Bradley's FactoryTalk View Machine Edition HMI terminal family (PanelView Plus, Plus CE, Plus 6 and Plus 7).
T
Operator inputTouch screen: analog resistive touch, no keypad.
7
Display size6.5-in. (640 x 480) display.
C
Display typeColor TFT LCD.
22
Ethernet portsTwo 10/100Base-T Ethernet ports with embedded switch, supports Device Level Ring (DLR), linear or star topologies.
A
PowerAC power input, 100…240V AC nominal, 50/60 Hz. AC models were built as Series A Performance terminals only (Series B is 24V DC only).
9
Operating systemPerformance-model operating-system position. The operating system and memory fitted depend on the hardware series, which this digit does not encode; the series letter is printed on the product label (per-series detail under Series & Revisions).
P
ModelPerformance model: FactoryTalk View ME with the Extended Features package (web browser, media player, PDF and document viewers). Operating system, RAM and storage differ by hardware series; see Series & Revisions.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Series & Revisions

No series in stock today; request a series above.

Series A: Windows CE 6.0, 512 MB RAM, firmware up to v12.

Series B: Windows 10 IoT Core, 4 GB RAM, firmware v12 and later; no Windows desktop or Remote Desktop client (VNC remote access remains).

AC-powered models exist as Series A only; Series B is 24V DC.

Series notes: Series B terminals may replace Series A terminals in compatible applications, but differences in operating systems, firmware, and supported features must be evaluated before replacement. Existing FactoryTalk View ME applications may require updates or modifications. A Series A can stand in for a Series B only if the runtime is saved for ME v12; its firmware stops there, so a project saved in ME v13 or later will not load.

PanelView Plus 7 Performance Series A vs Series B

Intended Use

Designed for machine operator interface (HMI) applications. PanelView Plus 7 terminals with a 6.5-in. display give operators graphics, alarms and trends for packaging, food and beverage, pharmaceutical, automotive and water applications, communicating with Logix controllers over EtherNet/IP and running FactoryTalk View ME applications.

Physical Data

Weight and DimensionsWeight2.65 lb (1.20 kg)H × W × D6.7 × 8.3 × 2.7 in. (170 × 212 × 69.6 mm)
Weight1.20 kg (2.65 lb)
Typical unit weight
Dimensions (H × W × D)170 × 212 × 69.6 mm (6.7 × 8.3 × 2.7 in.)
7-in. touch terminal
Shipping Weight2.33 kg (5.14 lb)
Estimated: unit weight plus box and packing material; bills as 6 lb
Shipping Box (L × W × H)20 × 14 × 10 in. (508 × 356 × 254 mm)
Smallest standard box fitting the product with 3 in. cushioning per side
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box.

Similar Part Numbers

CategoryPanelView Plus
Part Number2711P-T7C22A9P
ManufacturerAllen-Bradley

Previously sold 2711P-T7C22A9P

2 sold

NJT Automation has supplied and shipped 2 2711P-T7C22A9P PanelView Plus 7 Performance touch terminals since 2024; request a quote and we will source another from our supplier network.

Sold
2 since 2024
Series
A × 2
Allen-Bradley 2711P-T7C22A9P Unused surplus (open box) - previously sold by NJT AutomationSold

Allen-Bradley 2711P-T7C22A9P PanelView Plus 7 Terminal

$4,599.99 USDUnused surplus (open box)
Request Quote

Can the 2711P-T7C22A9P be repaired?

Yes. NJT Automation repairs the 2711P-T7C22A9P by mail-in: diagnostic evaluation, component-level repair and a functional test.

Option 1

NJT Managed Repair

Evaluation
Free evaluation.
Shipping
Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
Pricing
$650 minimum for successful repairs.
Warranty
1-year full-function warranty included. 2- and 3-year options available.
Get a repair quoteOr text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

Find an HMI repair specialiston RepairMode.com ↗

Common Failures

Failure patterns we regularly see on PanelView Plus 7 Performance touch terminal hardware like the 2711P-T7C22A9P:

  • Vertical or horizontal lines, dead pixels or image retention on the LCD
  • No power LED or resets under load after a 24V DC surge or brownout: failed electrolytic capacitors or input protection on the power supply board
  • Ethernet port dead or DLR ring faults on two-port models: damaged magnetics or PHY
  • LED backlight dimming unevenly, flickering or going dark: backlight driver on the display board
  • Touch controller board fault: calibration will not hold, or whole-screen dead zones with an undamaged overlay

Fault code reference

2711P-T7C22A9P Fault Codes

6 codes · 2711P-UM008View codesHide codes

Fault codes a PanelView Plus 7 Performance touch terminal reports on the start-up screen (shown as Fatal followed by a two-character code) and the ERR (red) and STS (green) indicators on the back of the terminal, as documented in Rockwell Automation publication 2711P-UM008. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

Fatal start-up codes

2711P-T7C22A9P Fatal start-up codes
CodeFailureWhat it indicates
Fatal 02Watchdog errorA watchdog reset occurred. By default the terminal shows the error at start-up and halts at the maintenance window instead of booting the application; monitor for recurrence.
Fatal 3AStuck touchThe start-up self-test found a touch cell held or stuck. Make sure nothing is pressing on the screen (including a damaged anti-glare overlay) and reset the terminal without touching it; if it persists, the fault is in the touch screen / display assembly.

Fatal 02 is documented in 2711P-UM007 / UM008; Fatal 3A on PanelView Plus 7 is documented in the Rockwell Knowledgebase article "PanelView Plus Fatal 3A at Boot up", which covers all PanelView Plus, Plus 6 and Plus 7 touch models.

Status indicator states during start-up

2711P-T7C22A9P Status indicator states during start-up
IndicatorsStateWhat it indicates
ERR blinking · STS offRecoverable firmware error / configuration failureReload the firmware or restore the terminal to its factory default image.
ERR on · STS onFatal hardware errorA hardware fault inside the terminal that a reset or firmware reload will not clear.
ERR on · STS blinkingFatal display hardware errorA hardware fault in the terminal's display section that a reset or firmware reload will not clear.
ERR off · STS offNo powerIndicators flash at start-up and STS stays on after a successful boot; if both stay off, check the power cable and supply.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 2711P-UM008, PanelView Plus 7 Performance Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

PanelView Plus 7 fault code reference · every code and every part number it covers

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 2711P-T7C22A9P is a PanelView Plus 7 Performance 6.5-in. color TFT touch terminal, dual Ethernet ports (DLR), AC powered.
The 2711P-T7C22A9P may be available on request in Unused surplus / Refurbished / Used condition. We can quote this part in unused surplus, refurbished, or used condition depending on availability and your preference. Specify your requirement in the RFQ.
At NJT Automation, 2 2711P-T7C22A9P PanelView Plus 7 Performance touch terminals have sold since 2024 for $2,000 – $4,600. None are in stock at the moment; request a quote for current pricing, or have your PanelView Plus 7 Performance touch terminal repaired by NJT Automation (see the repair section on this page).
The 2711P-T7C22A9P is sourced on request. Request a quote and we'll confirm availability and lead time, typically a few business days.
6.5-in. (640 x 480) display.
AC power input, 100…240V AC nominal, 50/60 Hz.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.