View Cart

Allen-Bradley 2711P-T7C4D9 PanelView Plus 6 6.5-in. Touch, 24V DC

Allen-Bradley 2711P-T7C4D9 PanelView Plus 6 6.5-in. color touch terminal, Ethernet + RS-232, 24V DC powered. NJT Automation sources the 2711P-T7C4D9 on request; send the part number for a replacement or repair quote.

Quote required. Request a quote below for pricing and delivery.

Request Replacement QuoteRequest Repair Quote
Part Number2711P-T7C4D9
Price
On Request
Availability and condition determine final quote.
DescriptionPanelView Plus 6 touch terminal, 6.5-in. Touch, 24V DC.
Shipping
UPS Ground
Included. Next-Day Air and worldwide shipping available.
Courier
Within 350 miles, est. $3.50/mile, subject to availability.
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price
3 years
+25% of product price
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send in your defective 2711P-T7C4D9 for a 10% core credit.

Availability
Sourced on RequestIndependently SourcedNot an OEM-Authorized Distributor

We do not have a 2711P-T7C4D9 on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit.

Sourcing

Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup.

Request QuoteHow Level 1 sourcing works
Repairs

2711P-T7C4D9 Mail-In Repair Service

Part Number Decoder

PanelView Plus 6 touch terminal
2711PT7C4D9
2711P
BulletinPanelView Plus: Allen-Bradley's FactoryTalk View Machine Edition HMI terminal family (PanelView Plus, Plus CE, Plus 6 and Plus 7).
T
Operator inputTouch screen: analog resistive touch, no keypad.
7
Model / size700 model: 6.5-in. display.
C
Display typeColor display (active-matrix TFT on 700…1500; color STN/TFT on 400/600).
4
CommunicationEthernet (10/100 Mbps), RS-232 serial and two USB host ports, with a slot for an optional DH+/DH-485 (RN6), ControlNet (RN15S) or second Ethernet (RN20) module.
D
Power24V DC power input (18…30V DC).
9
Operating system / featuresWindows CE 6.0 with Extended Features: Internet Explorer, remote desktop, media player and Microsoft Office file viewers.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Series & Revisions

700 to 1500 terminals are modular: the 2711P-RP8 / RP9 logic module, not the display, carries the OS and firmware.

Series notes: Displays of the same size interchange across series. Match or exceed the logic module's firmware so the existing .mer runs.

Intended Use

Built for machine operator interface (HMI) applications. PanelView Plus terminals with a 6.5-in. display are the operator screens on packaging, food and beverage, pharmaceutical, automotive and water equipment, running FactoryTalk View ME applications against Logix, SLC and PLC-5 controllers.

Physical Data

Weight and DimensionsWeight3.75 lb (1.70 kg)H × W × D7 × 9.7 × 2.2 in. (179 × 246 × 55 mm)
Weight1.70 kg (3.75 lb)
Typical unit weight
Dimensions (H × W × D)179 × 246 × 55 mm (7 × 9.7 × 2.2 in.)
700 touch terminal
Shipping Weight2.83 kg (6.24 lb)
Estimated: unit weight plus box and packing material; bills as 7 lb
Shipping Box (L × W × H)20 × 14 × 10 in. (508 × 356 × 254 mm)
Smallest standard box fitting the product with 3 in. cushioning per side
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box.

Similar Part Numbers

  • 2711P-T10C4D9 Model / size: 1000 model
  • 2711P-T12C4D9 Model / size: 1250 model
  • 2711P-T7C4D8 Operating system / features: Windows CE 6.0 with standard features
  • 2711P-B15C4D9 Operator input: Keypad and touch screen combined; Model / size: 1500 model
  • 2711P-T10C4D8 Model / size: 1000 model; Operating system / features: Windows CE 6.0 with standard features

Allen-Bradley Information

Technical SpecificationsLifecycle status
LifecycleDiscontinued
Verify current status with the manufacturer.
CategoryPanelView Plus
Part Number2711P-T7C4D9
ManufacturerAllen-Bradley

Can the 2711P-T7C4D9 be repaired?

Yes. NJT Automation repairs the 2711P-T7C4D9 by mail-in: diagnostic evaluation, component-level repair and a functional test.

Option 1

NJT Managed Repair

Evaluation
Free evaluation.
Shipping
Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
Pricing
$650 minimum for successful repairs.
Warranty
1-year full-function warranty included. 2- and 3-year options available.
Get a repair quoteOr text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

Find an HMI repair specialiston RepairMode.com ↗

Common Failures

Failure patterns we regularly see on PanelView Plus 6 touch terminal hardware like the 2711P-T7C4D9:

  • Ethernet port on the logic module dead or dropping the PLC connection
  • Cracked bezel or compressed gasket letting washdown reach the display module
  • Overlay scratched, bubbled or delaminating at the edges
  • Logic-to-display connector pins worn from repeated separation
  • Touch digitizer unresponsive, drifting or registering ghost touches: worn analog-resistive overlay on the display module

Fault code reference

2711P-T7C4D9 Fault Codes

19 codes · 2711P-UM006View codesHide codes

Fault codes a PanelView Plus 6 touch terminal reports on the start-up splash screen (shown as Fatal followed by a two-character code, for example Fatal 3A) and the Fault (red) and Comm (green) indicators, as documented in Rockwell Automation publication 2711P-UM006. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

Fatal start-up codes

2711P-T7C4D9 Fatal start-up codes
CodeFailureWhat it indicates
Fatal 02Watch dog resetA momentary loss of control due to a software failure. The terminal halts at the maintenance window; monitor for recurrence.
Fatal 03Failed RAMPOST failure in the terminal's RAM; a hardware fault in the logic module (700…1500) or the terminal's logic board (400/600).
Fatal 0FFirmware update failureFatal during firmware loading. Reset from the maintenance menu, restore factory defaults or reinstall firmware.
Fatal 1EFirmware validation (CRC/format) failureFatal during firmware loading (1E also appears as a normal 'Update' progress code). Reset, restore defaults or reinstall firmware.
Fatal 1FFirmware compatibility index failureFirmware failed to validate the compatibility index of a firmware region; reinstall the correct firmware.
Fatal 31Stuck keyPOST found a function key held or stuck. Make sure nothing presses on the keypad and reset the terminal without touching any key; if it persists, the fault is in the keypad / display module.
Fatal 3AStuck touchPOST found a touch cell held or stuck. Make sure nothing is pressing on the screen (including a damaged anti-glare overlay), then reset without touching it; if it persists, the fault is in the touch screen / display module.
Fatal 3BFailed backlightPOST could not start the backlight; a hardware fault in the display module. If 3A or 3B appears right after an LED-backlit (newer series) display module was fitted to an older logic module, check the logic module firmware first (2711P-IN030 requires 7.00.20 or later for LED displays on Plus 6).
Fatal A5Firmware write to storage failureFatal during firmware loading (A5 also appears as a normal 'Update/Restore' progress code). Reset, restore defaults or reinstall firmware.
Fatal D2Firmware stored image verification failureFatal during firmware loading; reset, restore defaults or reinstall firmware.
Fatal FFInvalid or missing OS firmware imageNo valid operating system image (FF also appears as a normal 'AutoTest' progress code). Reinstall firmware.
Fatal R0Failed to initialize restore operationFatal during a restore; reset the terminal from the maintenance menu.
Fatal R1Invalid header in .pvb fileFatal during a restore; the backup file header is invalid.
Fatal R2Invalid headerFatal during a restore.
Fatal R3Cannot write intermediate filesFatal during a restore; the terminal could not write intermediate files.
Fatal R4Corrupt .pvb fileFatal during a restore; the backup file is corrupt.

The splash screen shows the state word and the code together, for example "Fatal 3A". Codes shown with the state AutoTest, Boot, Init, Update or Restore (E6, FF, G0, H1–JA, K1–MA, 1E, A5, DC) are normal progress messages; only codes shown with the state Fatal are errors. Rockwell Knowledgebase 459615 reproduces this list.

Status indicator states if the terminal stops during start-up

2711P-T7C4D9 Status indicator states if the terminal stops during start-up
IndicatorsStateWhat it indicates
Fault blinking · Comm offRecoverable firmware errorLast firmware download failed. Reload the firmware with the Firmware Upgrade Wizard.
Fault on · Comm offNon-recoverable logic module faultHardware fault in the logic module (700…1500) or the terminal's logic board (400/600); not recoverable by a reset or firmware reload.
Fault on · Comm blinkingNon-recoverable display module faultHardware fault in the display module (700…1500) or the terminal's display section (400/600); not recoverable by a reset or firmware reload.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 2711P-UM006, PanelView Plus 6 Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 2711P-T7C4D9 is a PanelView Plus 6 6.5-in. color touch terminal, Ethernet + RS-232, 24V DC powered.
The 2711P-T7C4D9 may be available on request in Unused surplus / Refurbished / Used condition. We can quote this part in unused surplus, refurbished, or used condition depending on availability and your preference. Specify your requirement in the RFQ.
The 2711P-T7C4D9 is sourced on request. Request a quote and we'll confirm availability and lead time, typically a few business days.
24V DC power input (18…30V DC).
Touch screen: analog resistive touch, no keypad.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.