NJT Automation has supplied and shipped 4 5069-L310ERM CompactLogix 5380 controllers since 2024; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 4 since 2024
- Series
- A × 4
In stock: 1 unit in Milwaukee, WI.
CompactLogix 5380 controller · 1 MB user memory · dual EtherNet/IP ports · 24 nodes · 8 local I/O modules

Actual NJT inventory photos
Price
$2,499.99USDRefurbished, Series AView listing
| Part Number | 5069-L310ERM |
| Description | CompactLogix 5380 controller, 1 MB, Dual EtherNet/IP. In stock in refurbished condition, Series A. |
| Shipping | Ships same or next business day
|
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 5069-L310ERM for a 10% core credit. |
| Variants | Part NumberConditionSeriesQtyPrice 5069-L310ERM /A$2,499.99 Refurbished · Series A · 1 in stock5069-L310ERM /ARefurbishedSeries A1$2,499.99 USD | ||||||||||||||||||||||||
| Availability | 1 Unit in StockIndependently SourcedNot an OEM-Authorized Distributor | ||||||||||||||||||||||||
| Repairs | 5069-L310ERM Mail-In Repair ServiceEstimated: $1,440.00 | ||||||||||||||||||||||||
Part Number Decoder | CompactLogix 5380 controller 5069·L310·ER·M·24
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||||||||||||||||||
Series & Revisions | Series A in stock; other series on request. Series notes: Logix keys on catalog number and firmware revision, not series; with the default Compatible Module keying, any series of the same catalog number is accepted in the slot. | ||||||||||||||||||||||||
Intended Use | Built for high-performance machine control with integrated motion and safety applications. CompactLogix 5380 controllers run fast packaging, converting, assembly and material-handling machines, with dual Ethernet ports for DLR rings and device-level segmentation, integrated CIP Motion axes, and GuardLogix variants for safety in the same controller. | ||||||||||||||||||||||||
Physical Data | Weight and DimensionsWeight1.69 lb (0.77 kg)H × W × D5.7 × 3.9 × 5.4 in. (144 × 98.1 × 136.8 mm)▾
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||||||||||||||||||
Allen-Bradley Information | Technical Specifications12 parameters from manufacturer-published specifications▾
Typical manufacturer-published values for this catalog number; confirm against the current manufacturer documentation before specifying. | ||||||||||||||||||||||||
| Category | CompactLogix 5000 | ||||||||||||||||||||||||
| UPC / GTIN | 0889508071329 | ||||||||||||||||||||||||
| Part Number | 5069-L310ERM | ||||||||||||||||||||||||
| Manufacturer | Allen-Bradley | ||||||||||||||||||||||||
NJT Automation has supplied and shipped 4 5069-L310ERM CompactLogix 5380 controllers since 2024; these listings are sold and the in-stock options above are ready to ship.
Yes. NJT Automation repairs the 5069-L310ERM by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Failure patterns we regularly see on CompactLogix 5380 controller hardware like the 5069-L310ERM:
Fault code reference
42 codes · 1756-RD001
Fault codes a CompactLogix 5380 controller reports on the Major Faults tab in Studio 5000 Logix Designer / RSLogix 5000 as Type:Code (T:C), as documented in Rockwell Automation publication 1756-RD001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
| Code | Fault | What it indicates |
|---|---|---|
| T01:C01 | Power-up fault | Power was lost and restored while the controller was in RUN mode. |
| T01:C16 | Power-up fault | I/O communications configuration fault detected at power-up. |
| T01:C40 | Power-up fault | Energy storage module or battery failed during the last power-down; retained data may be lost. |
| T01:C60 | Power-up fault | Non-recoverable fault. The controller must be reflashed or returned for repair. |
| T01:C61 | Power-up fault | Non-recoverable fault with saved diagnostic information. |
| T01:C62 | Power-up fault | Non-recoverable fault with saved diagnostic information and stored user program. |
| T03:C16 | I/O fault | An I/O module connection failed on a module marked as required. |
| T03:C20 | I/O fault | Unable to read ControlBus chassis information; the chassis may be bad. |
| T03:C21 | I/O fault | Unable to read ControlBus chassis information; the chassis may be bad. |
| T03:C23 | I/O fault | At least one required connection was not established before going into RUN mode. |
| T04:C16 | Program fault | Unknown instruction encountered. |
| T04:C20 | Program fault | Array subscript too large, or CONTROL data type POS or LEN invalid. |
| T04:C21 | Program fault | CONTROL data type LEN or POS less than 0. |
| T04:C24 | Program fault | Unknown data type passed to a subroutine. |
| T04:C31 | Program fault | JSR or RET did not pass as many parameters as expected. |
| T04:C34 | Program fault | A timer instruction had a negative value for its PRE or ACC. |
| T04:C42 | Program fault | JMP to a label that did not exist or was deleted. |
| T04:C82 | Program fault | Could not re-enter an executing SFC routine. |
| T04:C83 | Program fault | Value out of range. |
| T04:C84 | Program fault | Stack overflow: stack too small to perform the operation. |
| T04:C85 | Program fault | Invalid routine type. |
| T04:C89 | Program fault | Target step does not exist in the specified routine. |
| T04:C90 | Program fault | A safety instruction occurs outside a safety task. |
| T04:C91 | Program fault | Equipment phase instruction cannot be called from a program. |
| T04:C94 | Program fault | Nesting limits exceeded. |
| T04:C990–C999 | Program fault | User-defined major fault raised by the application. |
| T06:C01 | Watchdog fault | Task watchdog expired: an infinite loop, an over-complex program or a higher-priority task starved the task. |
| T07:C40 | Nonvolatile fault | Store to nonvolatile memory (CompactFlash / SD) failed. |
| T07:C41 | Nonvolatile fault | Load from nonvolatile memory failed: controller type mismatch. |
| T07:C42 | Nonvolatile fault | Load from nonvolatile memory failed: controller revision mismatch. |
| T07:C43 | Nonvolatile fault | Load from nonvolatile memory failed: bad checksum. |
| T07:C44 | Nonvolatile fault | Failed to restore processor memory. |
| T07:C50 | Nonvolatile fault | Security certificate invalid. |
| T08:C01 | Mode change fault | Mode change inhibited because a download is in progress. |
| T11:C01 | Motion fault | Actual position of the axis exceeded the positive overtravel limit. |
| T11:C02 | Motion fault | Actual position of the axis exceeded the negative overtravel limit. |
| T11:C03 | Motion fault | Actual position exceeded the position error tolerance. |
| T11:C04 | Motion fault | Encoder channel A, B or Z connection failed. |
| T11:C05 | Motion fault | Encoder noise event detected, or encoder signals not in quadrature. |
| T11:C06 | Motion fault | Drive fault reported by the servo drive. |
| T11:C07 | Motion fault | Synchronous connection to the servo module failed. |
| T11:C08 | Motion fault | Hardware failure in the servo module. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 1756-RD001, Logix 5000 Controller and I/O Fault Codes. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.
Find answers to shipping, warranties, repairs, and more.
Trademarks & Compatibility
All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.
Independent Supplier
NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.
Product Condition & Warranty
Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.
Firmware & Software Licensing
Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.
NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.
© 2026 NJT Automation. Independent industrial automation supplier and repair provider.