View Cart

Allen-Bradley 1746-NT8 SLC 500 8-channel

Allen-Bradley 1746-NT8 SLC 500 thermocouple input module: 8-channel thermocouple / mV input, 16-bit, 1746 chassis mount. NJT Automation sources the 1746-NT8 on request; send the part number for a replacement or repair quote.

Quote required. Request a quote below for pricing and delivery.

Request Replacement QuoteRequest Repair Quote
Part Number1746-NT8
Price
On Request
Availability and condition determine final quote.
DescriptionSLC 500 thermocouple input module, 8-channel.
Shipping
UPS Ground
Included. Next-Day Air and worldwide shipping available.
Courier
Within 350 miles, est. $3.50/mile, subject to availability.
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price
3 years
+25% of product price
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send us your defective 1746-NT8 after your purchase for a 10% core credit. We also purchase old or damaged parts outright.

Availability
Sourced on request

We do not have a 1746-NT8 on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit.

Sourcing

Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup.

Request QuoteHow Level 1 sourcing works
Repairs

1746-NT8 Mail-In Repair Service

Part Number Decoder

SLC 500 thermocouple input module
1746NT88
1746
BulletinSLC 500 I/O bulletin: chassis, power supplies and I/O modules for the SLC 500 modular system (processors are bulletin 1747).
NT8
Module typeThermocouple input module: 8-channel thermocouple / mV input, 16-bit.
8
Channel count8-channel module.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Intended Use

Built for temperature measurement applications. RTD and thermocouple modules measure oven, dryer, extruder and tank temperatures directly in an SLC 500 rack for closed-loop temperature control.

Migration Path

Rockwell Automation has discontinued the SLC 500 platform, including 1746 I/O. Published successor for the SLC 500 1746 I/O: 5069-IY4 (x2) (Compact 5000 I/O under CompactLogix 5380).

  • With a 1747-AENTR in slot 0, the existing 1746 rack can keep running as EtherNet/IP remote I/O under a CompactLogix or ControlLogix, so I/O modules can be replaced like-for-like until the rack is converted.
  • 1492-CM1746 conversion modules and pre-wired cables land the existing 1746 terminal-block wiring on the new module without re-terminating field devices.

A like-for-like replacement or a repair keeps the existing program, wiring and panel layout; a migration is a project. Both are listed on this page so the choice can be made on lead time and budget.

Allen Bradley Information

Technical SpecificationsLifecycle status
LifecycleActive
Verify current status with the manufacturer.
CategorySLC 500
Part Number1746-NT8
ManufacturerAllen-Bradley

Can the 1746-NT8 be repaired?

Yes. NJT Automation repairs the 1746-NT8 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.

Option 1

NJT managed repair

Evaluation
Free. No repair, no charge.
Shipping
Prepaid UPS label both ways.
Pricing
$650 minimum. Rush service available.
Warranty
1-year full-function warranty included; 2- and 3-year options.
Get a repair quoteor text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

Find a PLC repair specialiston RepairMode.com ↗

Common Failures

Failure patterns we regularly see on SLC 500 thermocouple input module hardware like the 1746-NT8:

  • Channel drift, offset or a reading railed at full scale after overvoltage on the field loop
  • Calibration lost on one or more channels
  • Output channel stuck at zero or full scale (NO / NIO modules)
  • RTD / thermocouple channels reading wrong from a failed reference or CJC (NR / NT)
  • Noisy readings from a damaged filter section

Fault code reference

1746-NT8 Fault Codes

10 codes · 1747-RM001

An SLC 500 I/O module has no fault display of its own. When a SLC 500 thermocouple input module like the 1746-NT8 fails, the processor logs a slot-specific major error in status word S:6 (RSLogix 500), where xx is the two-digit slot number the module occupies. These slot codes are documented in Rockwell Automation publication 1747-RM001.

1746-NT8 fault codes
CodeFaultWhat it indicates
xx50Chassis data errorSlot xx returned bad chassis data; usually noise or grounding.
xx51Stuck runtime errorA stuck I/O module in slot xx: noise on a discrete module or a fault on a specialty module.
xx52Module missingThe module configured for slot xx is missing or was removed.
xx53Unused slot has moduleA slot declared unused contains a module, or a module reset itself.
xx54Wrong module typeThe module in slot xx is a different type than configured.
xx55Wrong I/O countThe discrete module in slot xx has a different I/O count than configured.
xx56Chassis configuration errorThe chassis configuration in the program does not match the hardware.
xx57–xx5ESpecialty module errorA specialty I/O module in slot xx faulted, timed out or has an invalid G / M0-M1 file configuration.
xx90–xx93Disabled-slot / ISR errorA specialty module in a disabled slot requested service or faulted, or its interrupt subroutine is invalid.
xx94Module inserted under powerA module was inserted under power in Run or Test mode, or reset itself.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 1747-RM001, SLC 500 Instruction Set Reference Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 1746-NT8 is an SLC 500 thermocouple input module: 8-channel thermocouple / mV input, 16-bit, 1746 chassis mount.
The 1746-NT8 may be available on request in Unused surplus / Refurbished / Used condition. We can quote this part in unused surplus, refurbished, or used condition depending on availability and your preference. Specify your requirement in the RFQ.
The 1746-NT8 is sourced on request. Request a quote and we'll confirm availability and lead time, typically a few business days.
8-channel module.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.