| Part Number | 1756-L32AWAA |
| Price | On Request Availability and condition determine final quote. |
| Description | Allen-Bradley 1756-L32AWAA ControlLogix Processor (ControlLogix Module). Key features: 750 KB memory, 32 I/O points, supports up to 16 local I/O modules, integrated power supply. |
| Shipping |
|
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 1756-L32AWAA for a 10% core credit. |
| Availability | Sourced on RequestNot an OEM-Authorized Distributor We do not have a 1756-L32AWAA on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit. | ||||||||
| Sourcing | Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup. | ||||||||
| Repairs | 1756-L32AWAA Mail-In Repair Service | ||||||||
Physical Data | Weight and DimensionsWeight0.87 lb (0.39 kg)H × W × D5.7 × 1.4 × 5.7 in. (145 × 35 × 145 mm)
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||
Allen-Bradley Information | Allen Bradley ControlLogix Controller 1756-L32AWAA Key Features/Specifications: 750 KB memory, 32 I/O points, supports up to 16 local I/O modules, integrated power supply. | ||||||||
| Category | ControlLogix | ||||||||
| Part Number | 1756-L32AWAA | ||||||||
| Manufacturer | Allen-Bradley | ||||||||
Can the 1756-L32AWAA be repaired?
Yes. NJT Automation repairs the 1756-L32AWAA by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
- Evaluation
- Free evaluation.
- Shipping
- Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
- Pricing
- $650 minimum for successful repairs.
- Warranty
- 1-year full-function warranty included. 2- and 3-year options available.
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Common ControlLogix failures
Failure patterns we regularly see on ControlLogix hardware like the 1756-L32AWAA:
- CPU major faults after power loss or corrupted projects
- 1756 Ethernet modules (EN2T / EN3T) dropping connections under load
- Power supply failures causing chassis-wide resets or a dead rack
- I/O module channel damage from field wiring faults
- Battery or energy storage module failures losing programs on older L6x CPUs
Fault code reference
1756-L32AWAA Fault Codes
42 codes · 1756-RD001View codesHide codes
Fault code reference
1756-L32AWAA Fault Codes
Fault codes a Logix 5000 controller reports on the Major Faults tab in Studio 5000 Logix Designer / RSLogix 5000 as Type:Code (T:C), as documented in Rockwell Automation publication 1756-RD001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
| Code | Fault | What it indicates |
|---|---|---|
| T01:C01 | Power-up fault | Power was lost and restored while the controller was in RUN mode. |
| T01:C16 | Power-up fault | I/O communications configuration fault detected at power-up. |
| T01:C40 | Power-up fault | Energy storage module or battery failed during the last power-down; retained data may be lost. |
| T01:C60 | Power-up fault | Non-recoverable fault. The controller must be reflashed or returned for repair. |
| T01:C61 | Power-up fault | Non-recoverable fault with saved diagnostic information. |
| T01:C62 | Power-up fault | Non-recoverable fault with saved diagnostic information and stored user program. |
| T03:C16 | I/O fault | An I/O module connection failed on a module marked as required. |
| T03:C20 | I/O fault | Unable to read ControlBus chassis information; the chassis may be bad. |
| T03:C21 | I/O fault | Unable to read ControlBus chassis information; the chassis may be bad. |
| T03:C23 | I/O fault | At least one required connection was not established before going into RUN mode. |
| T04:C16 | Program fault | Unknown instruction encountered. |
| T04:C20 | Program fault | Array subscript too large, or CONTROL data type POS or LEN invalid. |
| T04:C21 | Program fault | CONTROL data type LEN or POS less than 0. |
| T04:C24 | Program fault | Unknown data type passed to a subroutine. |
| T04:C31 | Program fault | JSR or RET did not pass as many parameters as expected. |
| T04:C34 | Program fault | A timer instruction had a negative value for its PRE or ACC. |
| T04:C42 | Program fault | JMP to a label that did not exist or was deleted. |
| T04:C82 | Program fault | Could not re-enter an executing SFC routine. |
| T04:C83 | Program fault | Value out of range. |
| T04:C84 | Program fault | Stack overflow: stack too small to perform the operation. |
| T04:C85 | Program fault | Invalid routine type. |
| T04:C89 | Program fault | Target step does not exist in the specified routine. |
| T04:C90 | Program fault | A safety instruction occurs outside a safety task. |
| T04:C91 | Program fault | Equipment phase instruction cannot be called from a program. |
| T04:C94 | Program fault | Nesting limits exceeded. |
| T04:C990–C999 | Program fault | User-defined major fault raised by the application. |
| T06:C01 | Watchdog fault | Task watchdog expired: an infinite loop, an over-complex program or a higher-priority task starved the task. |
| T07:C40 | Nonvolatile fault | Store to nonvolatile memory (CompactFlash / SD) failed. |
| T07:C41 | Nonvolatile fault | Load from nonvolatile memory failed: controller type mismatch. |
| T07:C42 | Nonvolatile fault | Load from nonvolatile memory failed: controller revision mismatch. |
| T07:C43 | Nonvolatile fault | Load from nonvolatile memory failed: bad checksum. |
| T07:C44 | Nonvolatile fault | Failed to restore processor memory. |
| T07:C50 | Nonvolatile fault | Security certificate invalid. |
| T08:C01 | Mode change fault | Mode change inhibited because a download is in progress. |
| T11:C01 | Motion fault | Actual position of the axis exceeded the positive overtravel limit. |
| T11:C02 | Motion fault | Actual position of the axis exceeded the negative overtravel limit. |
| T11:C03 | Motion fault | Actual position exceeded the position error tolerance. |
| T11:C04 | Motion fault | Encoder channel A, B or Z connection failed. |
| T11:C05 | Motion fault | Encoder noise event detected, or encoder signals not in quadrature. |
| T11:C06 | Motion fault | Drive fault reported by the servo drive. |
| T11:C07 | Motion fault | Synchronous connection to the servo module failed. |
| T11:C08 | Motion fault | Hardware failure in the servo module. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 1756-RD001, Logix 5000 Controller and I/O Fault Codes. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
ControlLogix and CompactLogix fault code reference · every code and every part number it covers
Photos by NJT Automation; test videos from NJT or network repair technicians.
Still have questions?
Find answers to shipping, warranties, repairs, and more.