View Cart

Allen-Bradley 1763-L16BWA MicroLogix 16-point – Pickup in Store

In stock: 2 units in Milwaukee, WI. Physically stocked and ready to ship or available for local pickup. Includes a 1-year full-function warranty.

MicroLogix 1100 controller · 10 × 24V DC inputs (4 high-speed) · 6 relay outputs · 2 analog inputs (0…10V) · 120/240V AC powered

Price

$549.99USDUsed, Series BView listing

1
Request Repair QuoteEstimated $1,440.00
Part Number1763-L16BWA
DescriptionMicroLogix 1100 controller, 16-point, 120/240V AC. In stock in used condition, Series B.
Shipping
Ships same or next business day
UPS Ground
Included. Next-Day Air and worldwide shipping available.
Courier
Within 350 miles, est. $3.50/mile, subject to availability.
Pickup
Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954.
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price ($82.50)
3 years
+25% of product price ($137.50)
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send us your defective 1763-L16BWA after your purchase for a 10% core credit. We also purchase old or damaged parts outright.

Replacement Options for 1763-L16BWA

Allen Bradley 1763-L16BWA Ser B MicroLogix 1100 PLC 120/240VAC Controller

$549.99 USDIn-stock match

Condition: Used

Series B

2 in stockView details
Variants
Part NumberConditionSeriesQtyPrice
1763-L16BWA /B$549.99
Used · Series B · 2 in stock
1763-L16BWA /BUsedSeries B2$549.99 USD

1763-L16BWA

Refurbished — pick series, then request a quote

Request Quote
1763-L16BWARefurbished—Request Quote
Availability
2 units in stock
Repairs

1763-L16BWA Mail-In Repair Service

Estimated: $1,440.00

Part Number Decoder

MicroLogix 1100 controller
1763L16BWA
1763
BulletinMicroLogix 1100: micro PLC with 8 KB memory (4 KB program + 4 KB data), embedded 10/100 EtherNet/IP port, isolated RS-232/485 combo port, built-in LCD, on-line editing and up to 4 × 1762 expansion modules.
L16
I/O count16-point controller: 10 discrete inputs and 6 discrete outputs built in, plus 2 embedded analog inputs.
B
Input type24V DC discrete inputs.
W
Output typeRelay discrete outputs.
A
Power120/240V AC controller power supply.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Series & Revisions

Series B in stock; other series on request.

Series notes: A later series runs the existing program after the processor type is changed in RSLogix 500. An earlier series may not if the program uses features from a newer OS/FRN.

Intended Use

Intended for Ethernet-connected small machine control applications. MicroLogix 1100 controllers handle compact machines, pump and fan sequencing, small conveyors and monitoring panels where built-in Ethernet and a front LCD are wanted at a low point count.

Physical Data

Weight and DimensionsWeight1.98 lb (0.90 kg)H × W × D3.5 × 4.3 × 3.4 in. (90 × 110 × 87 mm)
Weight0.90 kg (1.98 lb)
Typical unit weight
Dimensions (H × W × D)90 × 110 × 87 mm (3.5 × 4.3 × 3.4 in.)
MicroLogix 1100 controller
Shipping Weight1.62 kg (3.57 lb)
Estimated: unit weight plus box and packing material; bills as 4 lb
Shipping Box (L × W × H)14 × 12 × 10 in. (356 × 305 × 254 mm)
Smallest standard box fitting the product with 3 in. cushioning per side
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box.

Similar Part Numbers

Allen Bradley Information

Technical SpecificationsLifecycle status
LifecycleActive
Verify current status with the manufacturer.
CategoryMicroLogix
Part Number1763-L16BWA
ManufacturerAllen-Bradley
Previously sold 1763-L16BWA3 sold

NJT Automation has supplied and shipped 3 1763-L16BWA MicroLogix 1100 controllers since 2024; these listings are sold and the in-stock options above are ready to ship.

Sold
3 since 2024
Series
B × 2, A × 1
Allen-Bradley 1763-L16BWA Used - previously sold by NJT AutomationSold

Allen Bradley 1763-L16BWA Series B FW 12 MicroLogix 1100 16-Pt Controller

$498.99 USD

Used

Request Quote

Can the 1763-L16BWA be repaired?

Yes. NJT Automation repairs the 1763-L16BWA by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.

Option 1

NJT managed repair

Evaluation
Free. No repair, no charge.
Shipping
Prepaid UPS label both ways.
Pricing
$650 minimum. Rush service available.
Warranty
1-year full-function warranty included; 2- and 3-year options.
Get a repair quoteor text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

View completed 1763-L16BWA repairson RepairMode.com ↗

Common Failures

Failure patterns we regularly see on MicroLogix 1100 controller hardware like the 1763-L16BWA:

  • Embedded Ethernet port dead or dropping connections
  • Power supply section failure leaving a dead unit
  • Program lost after a power event
  • Channel 0 RS-232 / RS-485 port damaged by a hot-plugged cable
  • Output relays welded or burned on high-cycle machines (-BWA / -AWA)

Fault code reference

1763-L16BWA Fault Codes

44 codes · 1763-RM001

Fault codes a MicroLogix 1100 controller reports on the controller LCD and status word S:6 in RSLogix 500 / RSLogix Micro (hexadecimal), as documented in Rockwell Automation publication 1763-RM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

1763-L16BWA fault codes
CodeFaultWhat it indicates
0001NVRAM errorProgram memory was corrupted (power loss during download, noise, failing battery) and the default program was loaded.
0002Unexpected resetThe controller reset unexpectedly due to noise or an internal hardware failure; the default program is loaded.
0003Memory module program corruptMemory module memory error; can also appear when going to Run mode.
0004Memory integrity errorROM or RAM became corrupt at power-up or during the background integrity check.
0006Memory module hardware faultThe memory module hardware faulted or is incompatible with the operating system.
0007Memory module transfer errorFailure during memory module transfer.
0008Fatal internal software errorUnexpected software error; cycle power and reload the program.
0009Fatal internal hardware errorUnexpected hardware error; cycle power and reload the program.
000AOS missing or corruptThe operating system required for the user program is missing or corrupt.
000BBase hardware faultThe base hardware faulted or is incompatible with the operating system.
Show 34 more codes
0011Executable file 2 missingLadder file 2 is missing from the program.
0012Ladder program errorThe ladder program has a memory integrity problem.
0015I/O configuration file errorThe user program I/O configuration is invalid.
0016Startup protection faultThe user fault routine ran at power-up and S:1/13 was not cleared.
0017NVRAM / memory module mismatchS:2/9 is set and the memory module program does not match the controller program.
0018Memory module program incompatible with OSThe program stored in the memory module needs a newer operating system.
001AUser program incompatible with OSThe user program is incompatible with the controller operating system.
0020Minor error at end of scanA minor fault bit (S:5 bits 0–7) was set at the end of the scan.
0022Watchdog timer expiredThe program scan time exceeded the watchdog timeout in S:3H.
0023STI errorAn error occurred in the STI configuration; see the STI function file.
0028Invalid user fault routineThe fault routine number in S:29 is invalid or the routine does not exist.
0029Indirect address outside data spaceAn indirect address reference is outside the entire data file space.
002EEII errorAn error occurred in the EII configuration; see the EII function file.
0030Subroutine nesting exceeds limitJSR nesting exceeded the controller memory space.
0031Unsupported instructionThe program contains an instruction this controller does not support.
0032Sequencer outside data file spaceAn SQO / SQC / SQL length or position parameter references outside the data file space.
0033Bit shift / FIFO / LIFO crossed data fileA BSL, BSR, FFL, FFU, LFL or LFU parameter references outside the data file space.
0034Negative timer valueA negative value was loaded to a timer preset or accumulator.
0035Illegal instruction in interrupt fileA TND, REF or SVC instruction is used in an interrupt subroutine.
0036Invalid PID parameterAn invalid value is being used for a PID instruction parameter.
0037HSC errorAn error occurred in the high-speed counter configuration; see the HSC function file.
003BPTO errorAn error occurred in the PTO instruction configuration.
003CPWM errorAn error occurred in the PWM instruction configuration.
003DInvalid sequencer length / positionA sequencer length or position parameter is greater than 255.
003EInvalid bit shift or FIFO / LIFO parameterA BSR / BSL length is greater than 2048, or an FFU / FFL / LFU / LFL length is out of range.
003FCOP / CPW / FLL outside data file spaceA COP, CPW or FLL length parameter references outside the data space.
0042Invalid recipe numberNumber of recipes specified is greater than 256.
0044Invalid write to RTC function fileA write to the real-time clock function file contained invalid data.
0050Controller type mismatchThe controller type selected in the program does not match the actual controller.
0051Base type mismatchThe hardware base type selected in the program does not match the actual base.
0052Minimum series errorThe hardware minimum series in the program is newer than the actual hardware.
0083Max I/O cables exceededToo many expansion I/O cables in the system.
0084Max I/O power supplies exceededToo many expansion I/O power supplies in the system.
0085Max I/O modules exceededToo many expansion I/O modules in the system.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 1763-RM001, MicroLogix 1100 Programmable Controllers Instruction Set Reference Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Related services:All Repair Services

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 1763-L16BWA is a MicroLogix 1100 controller, 10 × 24V DC inputs (4 high-speed), 6 relay outputs, 2 analog inputs (0…10V), 120/240V AC powered, embedded EtherNet/IP and RS-232/485 ports with built-in LCD.
NJT Automation currently has 2 units of the 1763-L16BWA in stock in used condition (Series B). Each listing states its own condition and series. Used means a unit removed from service and sold without refurbishment. Cosmetic condition, any functional testing performed, and the warranty term are stated on each unit’s own listing. From the listing: This item is in good working condition with some signs of use and is fully functional. It comes with 90-day free returns and a 1 year NJT warranty.
The 1763-L16BWA starts at $549.99 (Used, Series B) at NJT Automation. 2 units are in stock. 3 1763-L16BWA MicroLogix 1100 controllers have sold since 2024.
2 units of the 1763-L16BWA MicroLogix 1100 controller are on the shelf in Milwaukee, WI, priced from $549.99. Orders before 5:00 PM Central on a business day ship the same day; next-day air is available at checkout.
120/240V AC controller power supply.
16-point controller: 10 discrete inputs and 6 discrete outputs built in, plus 2 embedded analog inputs.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.