Allen-Bradley 2093-AMP2 Kinetix 2000 Servo Drive 0.6 kW – Pickup in Store
In stock: 2 units in Milwaukee, WI. Physically stocked and ready to ship or available for local pickup. Includes a 1-year full-function warranty.
Kinetix 2000 axis module: 0.6 kW / 2.0 A rms (2.83 A 0-pk) inverter axis on the shared 325V DC bus · sercos interface

Actual NJT inventory photos
Price
$4,999.99USDRefurbished, Series AView listing
| Part Number | 2093-AMP2 |
| Description | Kinetix 2000 axis module (AM), 0.6 kW, 200V-class. In stock in refurbished condition, Series A. |
| Shipping | Ships same or next business day
|
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send us your defective 2093-AMP2 after your purchase for a 10% core credit. We also purchase old or damaged parts outright. |
Replacement Options for 2093-AMP2
| Variants | Part NumberConditionSeriesQtyPrice 2093-AMP2 /A$4,999.99 Refurbished · Series A · 2 in stock2093-AMP2 /ARefurbishedSeries A2$4,999.99 USD | ||||||
| Availability | 2 units in stock | ||||||
| Repairs | 2093-AMP2 Mail-In Repair ServiceEstimated: $2,895.00 | ||||||
Part Number Decoder | Kinetix 2000 axis module (AM) 2093AMP2
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||
Series & Revisions | Series A in stock; other series on request. | ||||||
Intended Use | Built for compact multi-axis servo motion applications. Kinetix 2000 axis modules add axes on the shared power rail for low-power, multi-axis machines such as small packaging, labeling, converting and medical equipment, with SERCOS motion from a Logix controller. | ||||||
Migration Path | Rockwell Automation has discontinued the Kinetix 2000. Published successor for the Kinetix 2000: Kinetix 5500 (2198-H) for low-power multi-axis systems, or Kinetix 5700 where axis counts and power are growing.
A like-for-like replacement or a repair keeps the existing program, wiring and panel layout; a migration is a project. Both are listed on this page so the choice can be made on lead time and budget. | ||||||
Physical Data | Weight and DimensionsWeight1.48 lb (0.67 kg)
Product weight are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||
Similar Part Numbers |
| ||||||
| Category | Kinetix 2000 | ||||||
| UPC / GTIN | 820919777226 | ||||||
| Part Number | 2093-AMP2 | ||||||
| Manufacturer | Allen-Bradley | ||||||
Previously sold 2093-AMP21 sold
NJT Automation has supplied and shipped one 2093-AMP2 Kinetix 2000 axis module in 2025; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 1 in 2025
- Series
- A × 1
Image gallery20 PHOTOSActual units photographed by NJT
Can the 2093-AMP2 be repaired?
Yes. NJT Automation repairs the 2093-AMP2 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.
Option 1
NJT managed repair
- Evaluation
- Free. No repair, no charge.
- Shipping
- Prepaid UPS label both ways.
- Pricing
- $650 minimum. Rush service available.
- Warranty
- 1-year full-function warranty included; 2- and 3-year options.
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Common Failures
Failure patterns we regularly see on Kinetix 2000 axis module (AM) hardware like the 2093-AMP2:
- Motor brake output failure: brake relay or brake driver on the control board not releasing the motor brake
- Ground fault (E34) that follows the module, not the motor: IGBT leakage or a current sensor fault
- IPM fault (E05): inverter IGBT module shorted after a motor or cable fault, usually taking the gate driver board with it
- Power rail connector pins bent, burned or backed out: module not recognized in that slot
- sercos ring fault (E50): failed fiber-optic transmitter or receiver on the axis module
Fault code reference
2093-AMP2 Fault Codes
40 codes · 2093-UM001
Fault codes a Kinetix 2000 axis module (AM) reports on the seven-segment status indicator on the IAM or AM module and the axis fault in RSLogix 5000, as documented in Rockwell Automation publication 2093-UM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.
| Code | Fault | What it indicates |
|---|---|---|
| E00 | Blown fuse | A blown fuse was detected on the inverter board; the module needs repair. |
| E04 | Motor overtemperature | Motor thermal switch tripped: high ambient, excessive current, wiring error or wrong motor. |
| E05 | Drive overcurrent (power fault) | The Intelligent Power Module tripped: shorted motor cables or windings, drive too hot, or a failed power stage. |
| E06 | Hardware overtravel | The axis moved beyond the physical travel limit input. |
| E07 | Motor feedback loss | Motor feedback wiring is open, shorted or missing. |
| E09 | Bus undervoltage | DC bus below limit with three-phase power present, or power removed while an axis was enabled. |
| E10 | Bus overvoltage | DC bus above limit, usually excessive regeneration. |
| E11 | Illegal Hall state | Hall feedback inputs are in an invalid state; check wiring at the MF connector. |
| E16 | Software overtravel | Axis position exceeded the software travel limit. |
| E18 | Overspeed | Motor speed exceeded 150% of maximum rated speed. |
Show 30 more codes
| E19 | Follow error | Position error limit exceeded; check tuning, feed-forward and mechanical load. |
| E20 | Motor feedback AQB | The motor encoder encountered an illegal quadrature transition, usually noise. |
| E21 | Aux feedback comm | Communication was not established with an intelligent auxiliary encoder. |
| E30 | Motor feedback comm | Communication was not established with the intelligent motor encoder. |
| E34 | Ground fault | Excessive ground current detected in the converter: wiring, motor ground short or internal fault. |
| E35 | Precharge fault | The converter precharge cycle failed: low AC input or an internal fault. |
| E36 | System overtemperature | Converter thermal switch tripped: excessive heat in the power circuitry. |
| E37 | Phase loss | One or more AC input phases missing, or the axis was enabled when main power was removed. |
| E38 | SERCOS ring fault | The SERCOS fiber ring dropped after being active; check fiber connections. |
| E39 | Self-sense fault | Self-sensing commutation start-up was obstructed. |
| E43 | Drive enable fault | Enable was attempted through software while the hardware enable input was inactive, or the input dropped. |
| E50 | SERCOS same address | Duplicate node address detected on the SERCOS ring. |
| E54 | Current feedback hardware fault | Current feedback hardware fault detected inside the drive; a hardware fault on the drive's control/power electronics that repair addresses. |
| E60 | Unknown axis | Illegal ID bits detected; a hardware fault inside the drive rather than in the wiring or application. |
| E61 / E62 | Aux feedback AQB / loss | Auxiliary encoder illegal transition, or auxiliary feedback wiring open / shorted / missing. |
| E65 | Hookup fault | The hookup test failed: motor power / feedback wiring or feedback device. |
| E66 | Autotune fault | The autotune procedure failed. |
| E67 | Task init | Operating system failed to initialize; hardware failure if it persists after a power cycle. |
| E68 | SCANport comm | DPI communication failed; check the device and cable. |
| E69 | Objects init | Non-volatile memory corrupt due to control-board hardware failure. |
| E70 | NV memory init | Non-volatile memory corrupt; load defaults and save. |
| E71 | Memory init | RAM or flash validation failure; if it persists through a power cycle, the fault is in the drive's control board. |
| E72 | Drive overtemperature | Inverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle. |
| E73 | Backplane comm | Power-rail CAN communication failed; check module seating and the power rail. |
| E74 | Bus overcurrent | DC link current exceeded rating; motor or transmission problem, or an undersized IAM. |
| E75 | Shunt time out | The IAM, AM or shunt module exceeded its shunt resistor continuous rating. |
| E76 | CAN init | DPI hardware initialization fault; control-board hardware failure. |
| E78 | SERCOS init | Control hardware fault detected at SERCOS initialization. |
| E79 | Shunt module fault | The shunt module reports a temperature or shunt fault, or is missing from the power rail. |
| E80 | CPLD fault | Control hardware fault detected; a fault inside the drive's control electronics. |
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.
Source: Rockwell Automation publication 2093-UM001, Kinetix 2000 Multi-axis Servo Drives User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.
Photos by NJT Automation; test videos from NJT or network repair technicians.