Allen-Bradley 2093 · Fault code reference
Kinetix 2000 Fault Codes
Every fault code a Kinetix 2000 reports on the seven-segment status indicator on the IAM or AM module and the axis fault in RSLogix 5000, with what each one indicates, as documented in Rockwell Automation publication 2093-UM001.
40 codes · 2093-UM001 · 7 part numbers covered
Kinetix 2000 fault code list
| Code | Fault | What it indicates |
|---|---|---|
| E00 | Blown fuse | A blown fuse was detected on the inverter board; the module needs repair. |
| E04 | Motor overtemperature | Motor thermal switch tripped: high ambient, excessive current, wiring error or wrong motor. |
| E05 | Drive overcurrent (power fault) | The Intelligent Power Module tripped: shorted motor cables or windings, drive too hot, or a failed power stage. |
| E06 | Hardware overtravel | The axis moved beyond the physical travel limit input. |
| E07 | Motor feedback loss | Motor feedback wiring is open, shorted or missing. |
| E09 | Bus undervoltage | DC bus below limit with three-phase power present, or power removed while an axis was enabled. |
| E10 | Bus overvoltage | DC bus above limit, usually excessive regeneration. |
| E11 | Illegal Hall state | Hall feedback inputs are in an invalid state; check wiring at the MF connector. |
| E16 | Software overtravel | Axis position exceeded the software travel limit. |
| E18 | Overspeed | Motor speed exceeded 150% of maximum rated speed. |
| E19 | Follow error | Position error limit exceeded; check tuning, feed-forward and mechanical load. |
| E20 | Motor feedback AQB | The motor encoder encountered an illegal quadrature transition, usually noise. |
| E21 | Aux feedback comm | Communication was not established with an intelligent auxiliary encoder. |
| E30 | Motor feedback comm | Communication was not established with the intelligent motor encoder. |
| E34 | Ground fault | Excessive ground current detected in the converter: wiring, motor ground short or internal fault. |
| E35 | Precharge fault | The converter precharge cycle failed: low AC input or an internal fault. |
| E36 | System overtemperature | Converter thermal switch tripped: excessive heat in the power circuitry. |
| E37 | Phase loss | One or more AC input phases missing, or the axis was enabled when main power was removed. |
| E38 | SERCOS ring fault | The SERCOS fiber ring dropped after being active; check fiber connections. |
| E39 | Self-sense fault | Self-sensing commutation start-up was obstructed. |
| E43 | Drive enable fault | Enable was attempted through software while the hardware enable input was inactive, or the input dropped. |
| E50 | SERCOS same address | Duplicate node address detected on the SERCOS ring. |
| E54 | Current feedback hardware fault | Current feedback hardware fault detected inside the drive; a hardware fault on the drive's control/power electronics that repair addresses. |
| E60 | Unknown axis | Illegal ID bits detected; a hardware fault inside the drive rather than in the wiring or application. |
| E61 / E62 | Aux feedback AQB / loss | Auxiliary encoder illegal transition, or auxiliary feedback wiring open / shorted / missing. |
| E65 | Hookup fault | The hookup test failed: motor power / feedback wiring or feedback device. |
| E66 | Autotune fault | The autotune procedure failed. |
| E67 | Task init | Operating system failed to initialize; hardware failure if it persists after a power cycle. |
| E68 | SCANport comm | DPI communication failed; check the device and cable. |
| E69 | Objects init | Non-volatile memory corrupt due to control-board hardware failure. |
| E70 | NV memory init | Non-volatile memory corrupt; load defaults and save. |
| E71 | Memory init | RAM or flash validation failure; if it persists through a power cycle, the fault is in the drive's control board. |
| E72 | Drive overtemperature | Inverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle. |
| E73 | Backplane comm | Power-rail CAN communication failed; check module seating and the power rail. |
| E74 | Bus overcurrent | DC link current exceeded rating; motor or transmission problem, or an undersized IAM. |
| E75 | Shunt time out | The IAM, AM or shunt module exceeded its shunt resistor continuous rating. |
| E76 | CAN init | DPI hardware initialization fault; control-board hardware failure. |
| E78 | SERCOS init | Control hardware fault detected at SERCOS initialization. |
| E79 | Shunt module fault | The shunt module reports a temperature or shunt fault, or is missing from the power rail. |
| E80 | CPLD fault | Control hardware fault detected; a fault inside the drive's control electronics. |
Is it a hardware fault?
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part, not at wiring, configuration or the application. Those are the faults NJT Automation repairs at component level. A repair is usually cheaper and faster than a replacement for an obsolete Kinetix 2000 unit; each part number below links to its stock, repair pricing and test videos.
Faults are read from the seven-segment status indicator on the IAM or AM module and the axis fault in RSLogix 5000.
Source
- Rockwell Automation publication 2093-UM001, Kinetix 2000 Multi-axis Servo Drives User Manual
Codes are listed as documented. Fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series. Spotted an error? Tell us and we will correct it.
Related references
Kinetix 2000 part numbers these codes apply to
7 catalog numbers, 4 in stock now. Each links to stock, condition, repair pricing and series notes for that catalog number.
- 2093-AC05-MP22 in stockKinetix 2000 integrated axis module (IAM)
- 2093-AM023 in stockKinetix 2000 axis module (AM)
- 2093-AMP22 in stockKinetix 2000 axis module (AM)
- 2093-AMP52 in stockKinetix 2000 axis module (AM)
- 2093 AC05
- 2093-AC05-MP1Kinetix 2000 integrated axis module (IAM)
- 2093-AC05-MP5Kinetix 2000 integrated axis module (IAM)