Allen-Bradley 2093-AC05-MP1 Kinetix 2000 Servo Drive
In stock: 1 unit in Milwaukee, WI. Physically stocked and ready to ship or available for local pickup. Includes a 1-year full-function warranty.
Kinetix 2000 integrated axis module: 170…264V AC · single- or three-phase input (200V-class) · 3 kW converter (2 kW on single-phase) feeding the power-rail DC bus · with a 0.3 kW / 1.0 A rms (1.41 A 0-pk) inverter axis · sercos interface

Actual NJT inventory photos
Price
$2,849.99USD
Refurbished units available
| Part Number | 2093-AC05-MP1 |
| Description | Kinetix 2000 integrated axis module (IAM), 0.3 kW, 200V-class. In stock in refurbished condition, Series A. |
| Shipping | Ships same or next business day UPS Ground included | Next-Day Air and Worldwide Shipping available at checkout |
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send us your defective 2093-AC05-MP1 after your purchase for a 10% core credit ($285). We also purchase old or damaged parts outright. |
Replacement Options for 2093-AC05-MP1
Pick a condition and series below. UPS Ground shipping included.
| Variants | Part NumberConditionSeriesQtyPrice 2093-AC05-MP1 /A$2,849.99 Refurbished · Series A · 1 in stock2093-AC05-MP1 /ARefurbishedSeries A1$2,849.99 USD | ||||||
| Availability | 1 unit in stock | ||||||
| Repairs | 2093-AC05-MP1 Mail-In Repair ServiceEstimated: $1,725.00 | ||||||
Part Number Decoder | Kinetix 2000 integrated axis module (IAM) 2093AC05MP1
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||
Series & Revisions | Series A in stock; other series on request. | ||||||
Intended Use | Designed for compact multi-axis servo motion applications. Kinetix 2000 integrated axis modules supply the DC bus and run the first axis for low-power, multi-axis machines such as small packaging, labeling, converting and medical equipment, with SERCOS motion from a Logix controller. | ||||||
Migration Path | Rockwell Automation has discontinued the Kinetix 2000. Published successor for the Kinetix 2000: Kinetix 5500 (2198-H) for low-power multi-axis systems, or Kinetix 5700 where axis counts and power are growing.
A like-for-like replacement or a repair keeps the existing program, wiring and panel layout; a migration is a project. Both are listed on this page so the choice can be made on lead time and budget. | ||||||
Physical Data | Weight and DimensionsWeight2.91 lb (1.32 kg)
Product weight are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||
Similar Part Numbers |
| ||||||
| Category | Kinetix 2000 | ||||||
| Part Number | 2093-AC05-MP1 | ||||||
| Manufacturer | Allen-Bradley | ||||||
Previously sold 2093-AC05-MP11 sold
NJT Automation has supplied and shipped one 2093-AC05-MP1 Kinetix 2000 integrated axis module in 2026; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 1 in 2026
- Series
- A × 1
Can the 2093-AC05-MP1 be repaired?
Yes. NJT Automation repairs the 2093-AC05-MP1 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.
NJT managed repair. No evaluation fee; no repair, no charge. Prepaid UPS label both ways, $650 minimum, rush available. 1-year full-function warranty included, 2- and 3-year options.
Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Find a servo drive repair specialiston RepairMode.com ↗Common failures
Failure patterns we regularly see on Kinetix 2000 integrated axis module (IAM) hardware like the 2093-AC05-MP1:
- Precharge fault (E35): precharge resistor open or precharge relay failed, so the DC bus never charges and the rail will not come up
- Converter section failure: input rectifier or converter IGBT module blown after a line-side surge, missing phase, or a shorted axis downstream
- IPM fault (E05) on the integrated axis: inverter IGBT module shorted after a motor or cable fault, gate driver board damaged with it
- Ground fault (E34) that follows the IAM, not the motor: leakage through a damaged IGBT module or current sensor
- Current sensor (Hall-effect) drift or failure: torque ripple, motor hum at enable, or false overcurrent trips
Photos by NJT Automation; test videos from NJT or network repair technicians.