Allen-Bradley 2093-AC05-MP2 Kinetix 2000 Servo Drive
Allen-Bradley 2093-AC05-MP2 Kinetix 2000 integrated axis module: 170…264V AC, single- or three-phase input (200V-class). NJT Automation offers mail-in repair for the 2093-AC05-MP2 with a 1-year warranty; replacement pricing is available on request.
Mail-in repair available now. Returned with a 1-year warranty. Replacement pricing on request.

Actual NJT inventory photos
| Part Number | 2093-AC05-MP2 |
| Price | On Request Previously sold for $2,599.99 - $2,999.99 USDAvailability and condition determine final quote. |
| Description | Kinetix 2000 integrated axis module (IAM), 0.6 kW, 200V-class. |
| Shipping | UPS Ground included | Next-Day Air and Worldwide Shipping available at checkout |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send us your defective 2093-AC05-MP2 after your purchase for a 10% core credit. We also purchase old or damaged parts outright. |
| Availability | Sourced on request We do not have a 2093-AC05-MP2 on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit. | ||||||
| Sourcing | Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup. | ||||||
| Repairs | 2093-AC05-MP2 Mail-In Repair ServiceEstimated: $1,725.00 | ||||||
Part Number Decoder | Kinetix 2000 integrated axis module (IAM) 2093AC05MP2
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||
Series & Revisions | No series in stock today; request a series above. | ||||||
Intended Use | Built for compact multi-axis servo motion applications. Kinetix 2000 integrated axis modules supply the DC bus and run the first axis for low-power, multi-axis machines such as small packaging, labeling, converting and medical equipment, with SERCOS motion from a Logix controller. | ||||||
Migration Path | Rockwell Automation has discontinued the Kinetix 2000. Published successor for the Kinetix 2000: Kinetix 5500 (2198-H) for low-power multi-axis systems, or Kinetix 5700 where axis counts and power are growing.
A like-for-like replacement or a repair keeps the existing program, wiring and panel layout; a migration is a project. Both are listed on this page so the choice can be made on lead time and budget. | ||||||
Physical Data | Weight and DimensionsWeight2.91 lb (1.32 kg)
Product weight are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||
Similar Part Numbers |
| ||||||
Allen Bradley Information | Technical SpecificationsLifecycle status
| ||||||
| Category | Kinetix 2000 | ||||||
| Part Number | 2093-AC05-MP2 | ||||||
| Manufacturer | Allen-Bradley | ||||||
Previously sold 2093-AC05-MP2
2 soldNJT Automation has supplied and shipped 2 2093-AC05-MP2 Kinetix 2000 integrated axis modules in 2026; request a quote and we will source another from our supplier network.
- Sold
- 2 in 2026
- Series
- A × 2
Can the 2093-AC05-MP2 be repaired?
Yes. NJT Automation repairs the 2093-AC05-MP2 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.
NJT managed repair. No evaluation fee; no repair, no charge. Prepaid UPS label both ways, $650 minimum, rush available. 1-year full-function warranty included, 2- and 3-year options.
Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Find a servo drive repair specialiston RepairMode.com ↗Common failures
Failure patterns we regularly see on Kinetix 2000 integrated axis module (IAM) hardware like the 2093-AC05-MP2:
- Cooling fan worn out: heatsink overtemperature trips and thermal stress on the power stage
- Ground fault (E34) that follows the IAM, not the motor: leakage through a damaged IGBT module or current sensor
- No logic power with control power (CP) present: failed switch-mode control power supply board inside the IAM
- Motor feedback lost / illegal Hall state (E07 / E11) with a known-good motor and cable: feedback interface board or the encoder supply
- Precharge fault (E35): precharge resistor open or precharge relay failed, so the DC bus never charges and the rail will not come up
Photos by NJT Automation; test videos from NJT or network repair technicians.
Still have questions?