View Cart

Allen-Bradley 2093-AC05-MP5 Kinetix 2000 Servo Drive – Repair Service Available

Allen-Bradley 2093-AC05-MP5 Kinetix 2000 integrated axis module: 170…264V AC, single- or three-phase input (200V-class). NJT Automation offers mail-in repair for the 2093-AC05-MP5 with a 1-year warranty; replacement pricing is available on request.

Mail-in repair available now. Returned with a 1-year warranty. Replacement pricing on request.

Request Replacement QuoteRequest Repair QuoteEstimated $2,895.00
Part Number2093-AC05-MP5
Price
On Request
Previously sold for $5,699.99 - $11,999.99 USDAvailability and condition determine final quote.
DescriptionKinetix 2000 integrated axis module (IAM), 0.9 kW, 200V-class.
Shipping
UPS Ground
Free
Expedited
Next-Day Air and worldwide shipping available
Courier
Within 350 miles · est. $3.50/mile, subject to availability
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price ($922.50)
3 years
+25% of product price ($1,537.50)
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send in your defective 2093-AC05-MP5 for a 10% core credit.

Availability
Sourced on RequestNot an OEM-Authorized Distributor

We do not have a 2093-AC05-MP5 on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit.

Sourcing

Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup.

Request QuoteHow Level 1 sourcing works
Repairs

2093-AC05-MP5 Mail-In Repair Service

Estimated: $2,895.00

Part Number Decoder

Kinetix 2000 integrated axis module (IAM)
2093AC05MP5
2093
BulletinKinetix 2000: the compact, low-power (0.3…3 kW per axis) 230V version of the Kinetix multi-axis servo system — an integrated axis module feeds up to seven axis modules over a shared DC bus on a Bulletin 2093 power rail; sercos interface to the Logix motion controller.
A
Voltage class170…264V AC, single- or three-phase input (200V-class).
C05
ConverterIntegrated axis module (IAM): AC-to-DC converter for the rail's 325V DC bus plus the system's first inverter. 3.0 kW continuous (6.0 kW peak) on three-phase input, derated to 2.0 kW (4.0 kW peak) on single-phase; 50 Ω / 15 W internal shunt. One IAM per power rail.
MP5
Inverter rating0.9 kW continuous inverter (axis) output: 3.0 A rms / 4.24 A (0-pk) continuous current, 3× peak for 3 s.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Series & Revisions

No series in stock today; request a series above.

Intended Use

Built for compact multi-axis servo motion applications. Kinetix 2000 integrated axis modules supply the DC bus and run the first axis for low-power, multi-axis machines such as small packaging, labeling, converting and medical equipment, with SERCOS motion from a Logix controller.

Physical Data

Weight and DimensionsWeight2.91 lb (1.32 kg)
Weight1.32 kg (2.91 lb)
Typical unit weight, Kinetix 2000 module
Shipping Weight2.04 kg (4.50 lb)
Estimated: unit weight plus box and packing material; bills as 5 lb
Shipping Box (L × W × H)14 × 12 × 10 in. (356 × 305 × 254 mm)
Most common box recorded for this catalog number
Product weight are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box.

Similar Part Numbers

Allen-Bradley Information

Technical SpecificationsLifecycle status
LifecycleDiscontinued
Verify current status with the manufacturer.
CategoryKinetix 2000
Part Number2093-AC05-MP5
ManufacturerAllen-Bradley

Previously sold 2093-AC05-MP5

4 sold

NJT Automation has supplied and shipped 4 2093-AC05-MP5 Kinetix 2000 integrated axis modules since 2025; request a quote and we will source another from our supplier network.

Sold
4 since 2025
Series
A × 1
Allen-Bradley 2093-AC05-MP5 Unused surplus (open box) - previously sold by NJT AutomationSold

Allen-Bradley 2093-AC05-MP5 Kinetix 2000 3kw/3A Intergrated Axis Module

$11,999.99 USDUnused surplus (open box)
Request Quote

Can the 2093-AC05-MP5 be repaired?

Yes. NJT Automation repairs the 2093-AC05-MP5 by mail-in: diagnostic evaluation, component-level repair and a functional test.

Option 1

NJT Managed Repair

Evaluation
Free evaluation.
Shipping
Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
Pricing
$650 minimum for successful repairs.
Warranty
1-year full-function warranty included. 2- and 3-year options available.
Get a repair quoteOr text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

View completed 2093-AC05-MP5 repairson RepairMode.com ↗

Common Failures

Failure patterns we regularly see on Kinetix 2000 integrated axis module (IAM) hardware like the 2093-AC05-MP5:

  • Bus undervoltage (E09) or bus overvoltage (E10): aged DC bus electrolytic capacitors, or regen energy the shunt cannot absorb
  • Precharge fault (E35): precharge resistor open or precharge relay failed, so the DC bus never charges and the rail will not come up
  • Converter section failure: input rectifier or converter IGBT module blown after a line-side surge, missing phase, or a shorted axis downstream
  • IPM fault (E05) on the integrated axis: inverter IGBT module shorted after a motor or cable fault, gate driver board damaged with it
  • Ground fault (E34) that follows the IAM, not the motor: leakage through a damaged IGBT module or current sensor

Fault code reference

2093-AC05-MP5 Fault Codes

40 codes · 2093-UM001View codesHide codes

Fault codes a Kinetix 2000 integrated axis module (IAM) reports on the seven-segment status indicator on the IAM or AM module and the axis fault in RSLogix 5000, as documented in Rockwell Automation publication 2093-UM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

2093-AC05-MP5 fault codes
CodeFaultWhat it indicates
E00Blown fuseA blown fuse was detected on the inverter board; the module needs repair.
E04Motor overtemperatureMotor thermal switch tripped: high ambient, excessive current, wiring error or wrong motor.
E05Drive overcurrent (power fault)The Intelligent Power Module tripped: shorted motor cables or windings, drive too hot, or a failed power stage.
E06Hardware overtravelThe axis moved beyond the physical travel limit input.
E07Motor feedback lossMotor feedback wiring is open, shorted or missing.
E09Bus undervoltageDC bus below limit with three-phase power present, or power removed while an axis was enabled.
E10Bus overvoltageDC bus above limit, usually excessive regeneration.
E11Illegal Hall stateHall feedback inputs are in an invalid state; check wiring at the MF connector.
E16Software overtravelAxis position exceeded the software travel limit.
E18OverspeedMotor speed exceeded 150% of maximum rated speed.
E19Follow errorPosition error limit exceeded; check tuning, feed-forward and mechanical load.
E20Motor feedback AQBThe motor encoder encountered an illegal quadrature transition, usually noise.
E21Aux feedback commCommunication was not established with an intelligent auxiliary encoder.
E30Motor feedback commCommunication was not established with the intelligent motor encoder.
E34Ground faultExcessive ground current detected in the converter: wiring, motor ground short or internal fault.
E35Precharge faultThe converter precharge cycle failed: low AC input or an internal fault.
E36System overtemperatureConverter thermal switch tripped: excessive heat in the power circuitry.
E37Phase lossOne or more AC input phases missing, or the axis was enabled when main power was removed.
E38SERCOS ring faultThe SERCOS fiber ring dropped after being active; check fiber connections.
E39Self-sense faultSelf-sensing commutation start-up was obstructed.
E43Drive enable faultEnable was attempted through software while the hardware enable input was inactive, or the input dropped.
E50SERCOS same addressDuplicate node address detected on the SERCOS ring.
E54Current feedback hardware faultCurrent feedback hardware fault detected inside the drive; a hardware fault on the drive's control/power electronics that repair addresses.
E60Unknown axisIllegal ID bits detected; a hardware fault inside the drive rather than in the wiring or application.
E61 / E62Aux feedback AQB / lossAuxiliary encoder illegal transition, or auxiliary feedback wiring open / shorted / missing.
E65Hookup faultThe hookup test failed: motor power / feedback wiring or feedback device.
E66Autotune faultThe autotune procedure failed.
E67Task initOperating system failed to initialize; hardware failure if it persists after a power cycle.
E68SCANport commDPI communication failed; check the device and cable.
E69Objects initNon-volatile memory corrupt due to control-board hardware failure.
E70NV memory initNon-volatile memory corrupt; load defaults and save.
E71Memory initRAM or flash validation failure; if it persists through a power cycle, the fault is in the drive's control board.
E72Drive overtemperatureInverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle.
E73Backplane commPower-rail CAN communication failed; check module seating and the power rail.
E74Bus overcurrentDC link current exceeded rating; motor or transmission problem, or an undersized IAM.
E75Shunt time outThe IAM, AM or shunt module exceeded its shunt resistor continuous rating.
E76CAN initDPI hardware initialization fault; control-board hardware failure.
E78SERCOS initControl hardware fault detected at SERCOS initialization.
E79Shunt module faultThe shunt module reports a temperature or shunt fault, or is missing from the power rail.
E80CPLD faultControl hardware fault detected; a fault inside the drive's control electronics.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 2093-UM001, Kinetix 2000 Multi-axis Servo Drives User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Kinetix 2000 fault code reference · every code and every part number it covers

Functional test video

Bench test from a completed 2093-AC05-MP5 repair.

RepairMode test video for 2093-AC05-MP5

Open the test video page

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 2093-AC05-MP5 is a Kinetix 2000 integrated axis module: 170…264V AC, single- or three-phase input (200V-class), 3 kW converter (2 kW on single-phase) feeding the power-rail DC bus, with a 0.9 kW / 3.0 A rms (4.24 A 0-pk) inverter axis; sercos interface.
The 2093-AC05-MP5 may be available on request in Unused surplus / Refurbished / Used condition. We can quote this part in unused surplus, refurbished, or used condition depending on availability and your preference. Specify your requirement in the RFQ.
At NJT Automation, 4 2093-AC05-MP5 Kinetix 2000 integrated axis modules have sold since 2025 for $5,700 – $12,000, with a median of $7,925. By condition, refurbished Kinetix 2000 integrated axis modules went for $5,700 – $6,600 and unused surplus Kinetix 2000 integrated axis modules went for $9,250 – $12,000. None are in stock at the moment; request a quote for current pricing, or have your Kinetix 2000 integrated axis module repaired by NJT Automation (see the repair section on this page).
The 2093-AC05-MP5 is sourced on request. Request a quote and we'll confirm availability and lead time, typically a few business days.
0.9 kW continuous inverter (axis) output: 3.0 A rms / 4.24 A (0-pk) continuous current, 3× peak for 3 s.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.