Allen-Bradley 2094-AM02 Kinetix 6000 Servo Drive 3.4 kW, 200V-class
Allen-Bradley 2094-AM02 Kinetix 6000 200V-class axis module (AM): 3.4 kW / 15 A (0-pk) inverter axis on the shared DC bus. NJT Automation sources the 2094-AM02 on request; send the part number for a replacement or repair quote.
Quote required. Request a quote below for pricing and delivery.

Actual NJT inventory photos
| Part Number | 2094-AM02 |
| Price | On Request Availability and condition determine final quote. |
| Description | Kinetix 6000 axis module (AM), 3.4 kW, 200V-class. |
| Shipping | UPS Ground included | Next-Day Air and Worldwide Shipping available at checkout |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send us your defective 2094-AM02 after your purchase for a 10% core credit. We also purchase old or damaged parts outright. |
| Availability | Sourced on request We do not have a 2094-AM02 on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit. | ||||
| Sourcing | Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup. | ||||
| Repairs | 2094-AM02 Mail-In Repair Service | ||||
Part Number Decoder | Kinetix 6000 axis module (AM) 2094AM02
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||
Series & Revisions | The -S (Kinetix 6000, SERCOS) and -M (Kinetix 6200 / 6500) suffixes are different control families and do not interchange on a rail. Series notes: Match the suffix. Within the same catalog number, flash the replacement to the firmware revision the Logix project expects before substituting. | ||||
Intended Use | Designed for multi-axis coordinated servo motion applications. Kinetix 6000 axis modules add axes on the shared power rail for coordinated multi-axis machines: packaging, converting, printing, web handling, material handling and pick-and-place, with SERCOS or EtherNet/IP motion from a Logix controller. | ||||
Migration Path | Rockwell Automation has discontinued the Kinetix 6000 (2094-xxxx-S) and published Kinetix 5700 as the successor for the whole 2094 family. Published successor for the Kinetix 6000 / 6200 / 6500: Kinetix 5700 (2198-P power supply, 2198-D dual-axis and 2198-S single-axis inverters).
A like-for-like replacement or a repair keeps the existing program, wiring and panel layout; a migration is a project. Both are listed on this page so the choice can be made on lead time and budget. | ||||
Physical Data | Weight and DimensionsWeight3.40 lb (1.54 kg)
Product weight are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||
Allen Bradley Information | Technical SpecificationsLifecycle status
| ||||
| Category | Kinetix 6000 | ||||
| Part Number | 2094-AM02 | ||||
| Manufacturer | Allen-Bradley | ||||
Can the 2094-AM02 be repaired?
Yes. NJT Automation repairs the 2094-AM02 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.
NJT managed repair. No evaluation fee; no repair, no charge. Prepaid UPS label both ways, $650 minimum, rush available. 1-year full-function warranty included, 2- and 3-year options.
Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Find a servo drive repair specialiston RepairMode.com ↗Common failures
Failure patterns we regularly see on Kinetix 6000 axis module (AM) hardware like the 2094-AM02:
- Ground fault (E34) that follows the module, not the motor: IGBT leakage or a current sensor fault
- Cooling fan worn out: drive overtemperature trips on the axis heatsink
- Current sensor (Hall-effect) drift or failure: torque ripple, false overcurrent, or a current offset fault at enable
- Logic power supply on the module shorted, pulling down control power for the whole rail
- sercos ring fault (E50): failed fiber-optic transmitter or receiver on the axis module
Photos by NJT Automation; test videos from NJT or network repair technicians.