Allen-Bradley 2094 · Fault code reference

Kinetix 6000 Fault Codes

Every fault code a Kinetix 6000 reports on the seven-segment status indicator on the IAM or AM module and the axis fault in RSLogix 5000, with what each one indicates, as documented in Rockwell Automation publication 2094-UM001.

48 codes · 2094-UM001 · 68 part numbers covered

Kinetix 6000 fault code list

Kinetix 6000 fault codes
CodeFaultWhat it indicates
E00Blown fuseA blown fuse was detected on the inverter board; the module needs repair.
E04Motor overtemperatureMotor thermal switch tripped: high ambient, excessive current, wiring error or wrong motor.
E05Drive overcurrent (power fault)The Intelligent Power Module tripped: shorted motor cables or windings, drive too hot, or a failed power stage.
E06Hardware overtravelThe axis moved beyond the physical travel limit input.
E07Motor feedback lossMotor feedback wiring is open, shorted or missing.
E09Bus undervoltageDC bus below limit with three-phase power present, or power removed while an axis was enabled.
E10Bus overvoltageDC bus above limit, usually excessive regeneration; check shunt sizing.
E11Illegal Hall stateHall feedback inputs are in an invalid state; check wiring at the MF connector.
E16Software overtravelAxis position exceeded the software travel limit.
E18OverspeedMotor speed exceeded 150% of maximum rated speed.
E19Follow errorPosition error limit exceeded; check tuning, feed-forward and mechanical load.
E20Motor feedback AQBThe motor encoder encountered an illegal quadrature transition, usually noise.
E21Aux feedback commCommunication was not established with an intelligent auxiliary encoder.
E30Motor feedback commCommunication was not established with the intelligent motor encoder.
E31Shaft movement at power-upMotor shaft moved during the power-up feedback test.
E34Ground faultExcessive ground current detected in the converter: wiring, motor ground short or internal fault.
E35Precharge faultThe converter precharge cycle failed: low AC input or an internal fault.
E36System overtemperatureConverter thermal switch tripped: excessive heat in the power circuitry.
E37Phase lossOne or more AC input phases missing, or the axis was enabled when main power was removed.
E38SERCOS ring faultThe SERCOS fiber ring dropped after being active; check fiber connections.
E39Self-sense faultSelf-sensing commutation start-up was obstructed.
E43Drive enable faultEnable was attempted through software while the hardware enable input was inactive, or the input dropped.
E49Safe-off hardware faultThe safe-off (STO) circuit reported a hardware fault.
E50SERCOS same addressDuplicate node address detected on the SERCOS ring.
E54Current feedback hardware faultCurrent feedback hardware fault detected inside the drive; a hardware fault on the drive's control/power electronics that repair addresses.
E55Velocity errorVelocity error exceeded the configured limit.
E60Unknown axisIllegal ID bits detected; a hardware fault inside the drive rather than in the wiring or application.
E61 / E62Aux feedback AQB / lossAuxiliary encoder illegal transition, or auxiliary feedback wiring open / shorted / missing.
E63 / E64Feedback noiseNoise on the motor or auxiliary feedback signals.
E65Hookup faultThe hookup test failed: motor power / feedback wiring or feedback device.
E66Autotune faultThe autotune procedure failed.
E67Task initOperating system failed to initialize; hardware failure if it persists after a power cycle.
E68SCANport commDPI / SCANport communication failed; check the device and cable.
E69Objects initNon-volatile memory corrupt due to control-board hardware failure.
E70NV memory initNon-volatile memory corrupt; load defaults and save.
E71Memory initRAM or flash validation failure; if it persists through a power cycle, the fault is in the drive's control board.
E72Drive overtemperatureInverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle.
E73Backplane commPower-rail CAN communication failed; check module seating and the power rail.
E74Bus overcurrentDC link current exceeded rating; motor or transmission problem, or an undersized IAM.
E75Shunt time outThe IAM, AM or shunt module exceeded its shunt resistor continuous rating.
E76CAN initDPI hardware initialization fault; control-board hardware failure.
E77Module mismatchA 230V and a 460V module are mixed on the same power rail.
E78SERCOS initControl hardware fault detected at SERCOS initialization.
E79Shunt module faultThe shunt module reports a temperature or shunt fault, or is missing from the power rail.
E80CPLD faultControl hardware fault detected; a fault inside the drive's control electronics.
E81Common bus faultCommon-bus configuration fault.
E90Precharge timeoutPrecharge did not complete in time.
E95IPIM faultThe Integrated Power Interface Module reported a fault.

Is it a hardware fault?

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part, not at wiring, configuration or the application. Those are the faults NJT Automation repairs at component level. A repair is usually cheaper and faster than a replacement for an obsolete Kinetix 6000 unit; each part number below links to its stock, repair pricing and test videos.

Faults are read from the seven-segment status indicator on the IAM or AM module and the axis fault in RSLogix 5000.

Source

Codes are listed as documented. Fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series. Spotted an error? Tell us and we will correct it.

Related references

Kinetix 6000 part numbers these codes apply to

68 catalog numbers, 7 in stock now. Each links to stock, condition, repair pricing and series notes for that catalog number.

Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.