Allen-Bradley 2099-BM08-S – Repair Service Available
Allen-Bradley 2099-BM08-S Kinetix 7000 37 kW (50 Hp) high-power servo drive, 460V AC three-phase input (or shared DC bus), 65 A rms continuous output, Sercos interface. NJT Automation offers mail-in repair for the 2099-BM08-S with a 1-year warranty; replacement pricing is available on request.
Mail-in repair available now. Returned with a 1-year warranty. Replacement pricing on request.

Actual NJT inventory photos
| Part Number | 2099-BM08-S |
| Price | On Request Previously sold for $16,499.99 USDAvailability and condition determine final quote. |
| Description | Kinetix 7000 high-power servo drive, 37 kW. |
| Shipping |
|
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send in your defective 2099-BM08-S for a 10% core credit. |
| Availability | Sourced on RequestNot an OEM-Authorized Distributor We do not have a 2099-BM08-S on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit. | ||
| Sourcing | Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup. | ||
| Repairs | 2099-BM08-S Mail-In Repair ServiceEstimated: $2,895.00 | ||
Part Number Decoder | Kinetix 7000 high-power servo drive 2099BM08S
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||
Series & Revisions | No series in stock today; request a series above. | ||
Intended Use | Built for high-power single-axis servo motion applications. Kinetix 7000 drives run 22 to 149 kW servo and induction motors on presses, extruders, winders, large converting lines, test stands and metal-forming machines under a Logix controller over Sercos. Discontinued in 2023, so most demand is like-for-like replacement or repair to avoid a Kinetix 5700 / PowerFlex 755 migration. Safe Torque Off lets the drive sit in the machine's safety circuit without an external contactor. | ||
Physical Data | Weight and DimensionsBox24 × 18 × 18 in.
Shipping box and weight are recorded from previous shipments of this catalog number and are provided for freight planning. | ||
Similar Part Numbers |
| ||
Allen-Bradley Information | Technical SpecificationsLifecycle status
| ||
| Category | Kinetix | ||
| Part Number | 2099-BM08-S | ||
| Manufacturer | Allen-Bradley | ||
Previously sold 2099-BM08-S
1 soldNJT Automation has supplied and shipped one 2099-BM08-S Kinetix 7000 high-power servo drive in 2026; request a quote and we will source another from our supplier network.
- Sold
- 1 in 2026
- Series
- A × 1
Can the 2099-BM08-S be repaired?
Yes. NJT Automation repairs the 2099-BM08-S by mail-in: diagnostic evaluation, component-level repair and a functional test.
Option 1
NJT Managed Repair
- Evaluation
- Free evaluation.
- Shipping
- Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
- Pricing
- $650 minimum for successful repairs.
- Warranty
- 1-year full-function warranty included. 2- and 3-year options available.
Option 2
Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.
Common Failures
Failure patterns we regularly see on Kinetix 7000 high-power servo drive hardware like the 2099-BM08-S:
- DC bus bar and power terminal connections overheating from loose or corroded joints
- Motor feedback lost / illegal Hall state (E07 / E11) with a known-good motor and cable: feedback interface board or the encoder supply
- Converter section failure: input rectifier or converter module blown after a line-side surge or missing phase
- IPM fault (E05): one of the inverter IGBT phase modules shorted after a motor or cable fault, gate driver board damaged with it
- Cooling fan or blower worn out: heatsink overtemperature trips and thermal stress on the IGBT modules
Photos by NJT Automation; test videos from NJT or network repair technicians.
Still have questions?
Find answers to shipping, warranties, repairs, and more.