Allen-Bradley 20BD052A3AYNAND0 PowerFlex 700 – Ready to Ship / Pick Up
In stock: 20BD052A3AYNAND0 PowerFlex 700 AC drive, 480V AC, 52 A / 40 Hp normal duty, Frame 3, IP20 NEMA Type 1: full-numeric LCD HIM, brake IGBT, CE filter + CM choke. NJT Automation has 2 units available in Milwaukee, WI, ready to ship or available for local pickup. Includes a one-year full-function warranty.

$4,299.99 – $5,999.99USD
| Part Number | 20BD052A3AYNAND0 |
| Description | PowerFlex 700 vector control AC drive, 40 Hp, 480V AC. In stock in refurbished condition, Series A and B. |
| Shipping | Ships today UPS Ground included | Next-Day Air and Worldwide Shipping available at checkout |
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send us your defective 20BD052A3AYNAND0 after your purchase for a 10% core credit ($430 – $600). We also purchase old or damaged parts outright. |
Replacement Options for 20BD052A3AYNAND0
In stock and ready to ship today
| Availability | Multiple Options Available | ||||||||
| Variants | Part NumberConditionSeriesQtyPrice 20BD052A3AYNAND0 /ARefurbishedSeries A1$4,299.99 USD20BD052A3AYNAND0 /BRefurbishedSeries B1$5,999.99 USD | ||||||||
| Repairs | 20BD052A3AYNAND0 Mail-In Repair ServiceEstimated: $2,575.00 | ||||||||
Part Number Decoder | PowerFlex 700 vector control AC drive 20BD052A3AYNAND0 PowerFlex 700 AC drive, 480V AC, 52 A / 40 Hp normal duty, Frame 3, IP20 NEMA Type 1: full-numeric LCD HIM, brake IGBT, CE filter + CM choke, no comm adapter, vector control, 115V I/O, no encoder.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||
Physical Data | Weight and DimensionsWeight40.9 lb (18.6 kg)H × W × D20.4 × 8.7 × 7.9 in. (517.5 × 222 × 200 mm)
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||
Datasheet | Datasheet available for download Generated from product specifications; not an official Allen-Bradley datasheet. For an official datasheet, contact Allen-Bradley or an authorized distributor. | ||||||||
Similar Part Numbers |
| ||||||||
| Category | PowerFlex 700 | ||||||||
| UPC / GTIN | 0820919100703 | ||||||||
| Part Number | 20BD052A3AYNAND0 | ||||||||
| Manufacturer | Allen-Bradley | ||||||||
Previously sold 20BD052A3AYNAND01 sold
NJT Automation has supplied and shipped one 20BD052A3AYNAND0 PowerFlex 700 vector control AC drive in 2026; these listings are sold and the in-stock options above are ready to ship.
- Sold
- 1 in 2026
- Price
- $3,000
- Series
- A × 1
The one 20BD052A3AYNAND0 PowerFlex 700 vector control AC drive sold in 2026 was refurbished and went for $3,000.
Can the 20BD052A3AYNAND0 be repaired?
Yes. NJT Automation offers mail-in repair for the 20BD052A3AYNAND0, including diagnostic evaluation, component-level repair, and functional testing.
One vendor. One warranty. NJT manages the entire process.
- 1-year full-function NJT warranty, with 2- and 3-year options available
- Rush service available for production-critical repairs
- No evaluation or diagnostic charges
- No repair, no charge
- "Unrepairable" is not an option
- Pre-paid UPS shipping label provided for sending your unit in
- $650 minimum repair charge, shipping included both ways
Looking for another option? For lower-cost repairs or if you prefer to work directly with an independent repair specialist, compare bids through RepairMode. RepairMode providers operate independently and set their own pricing and warranty terms.
Find a VFD repair specialiston RepairMode.com ↗Common 20BD052A3AYNAND0 failures
Failure patterns we regularly see on PowerFlex 700 vector control AC drive hardware like the 20BD052A3AYNAND0:
- DC bus capacitor aging: undervoltage trips (F4) or a drive that will not finish precharge
- Precharge relay / circuit failure leaving the drive stuck in precharge
- Hardware overcurrent (F12) or ground fault (F13) from a failed power stage after a motor or cable short
- Heatsink overtemperature (F8) from a failed fan or blocked airflow
- Control board failure: no display, no response or a HIM that never connects
Repair or replace?
Request a Repair Quote
Text photos of the faulty unit and the symptoms to (414) 331-5954.
All product photos were taken by NJT Automation. Test videos originated from either NJT Automation internally or from repair technicians within our network.
Still have questions?
Find answers to shipping, warranties, repairs, and more.