Allen-Bradley 20BD027A3AYNANC0 PowerFlex 700 – Ready to Ship / Pick Up
In stock: 20BD027A3AYNANC0 PowerFlex 700 AC drive, 480V AC, 27 A / 20 Hp normal duty, Frame 2, IP20 NEMA Type 1: full-numeric LCD HIM, brake IGBT, CE filter + CM choke. NJT Automation has 1 unit available in Milwaukee, WI, ready to ship or available for local pickup. Includes a one-year full-function warranty.

$2,999.99USD
| Part Number | 20BD027A3AYNANC0 |
| Description | PowerFlex 700 vector control AC drive, 20 Hp, 480V AC. In stock in refurbished condition, Series B. |
| Shipping | Ships today UPS Ground included | Next-Day Air and Worldwide Shipping available at checkout |
| Pickup | Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954. |
| Warranty | 1-year full-function warranty provided by NJT Automation. Warranty details
|
| Returns | 90-day free returns. View return policy |
| Exchange | Send us your defective 20BD027A3AYNANC0 after your purchase for a 10% core credit ($300). We also purchase old or damaged parts outright. |
Replacement Options for 20BD027A3AYNANC0
In stock and ready to ship today
| Variants | Part NumberConditionSeriesQtyPrice 20BD027A3AYNANC0 /B$2,999.99 Refurbished · Series B · 1 in stock20BD027A3AYNANC0 /BRefurbishedSeries B1$2,999.99 USD | ||||||||
| Availability | Similar Match Available A similar unit is in stock and ready to ship once you confirm the condition you need. | ||||||||
| Repairs | 20BD027A3AYNANC0 Mail-In Repair ServiceEstimated: $1,500.00 | ||||||||
Part Number Decoder | PowerFlex 700 vector control AC drive 20BD027A3AYNANC0 PowerFlex 700 AC drive, 480V AC, 27 A / 20 Hp normal duty, Frame 2, IP20 NEMA Type 1: full-numeric LCD HIM, brake IGBT, CE filter + CM choke, no comm adapter, vector control, 24V I/O, no encoder.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here. | ||||||||
Series & Revisions | Series B in stock; other series on request. | ||||||||
Intended Use | Designed for high-performance vector drive applications. PowerFlex 700 drives handle demanding loads such as extruders, winders, cranes and hoists, centrifuges, test stands and large conveyors, with flux vector control, encoder feedback, torque control and DPI communication adapters. | ||||||||
Migration Path | Rockwell Automation has discontinued the PowerFlex 700. Published successor for the PowerFlex 700: PowerFlex 753 20F11ND027AA0NNNNN (same voltage class and normal-duty current), or the equivalent PowerFlex 755 (20G) for embedded EtherNet/IP and more option slots.
A like-for-like replacement or a repair keeps the existing program, wiring and panel layout; a migration is a project. Both are listed on this page so the choice can be made on lead time and budget. | ||||||||
Physical Data | Weight and DimensionsWeight27.6 lb (12.5 kg)H × W × D13.5 × 8.7 × 7.9 in. (342.5 × 222 × 200 mm)
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box. | ||||||||
Datasheet | Datasheet available for download Generated from product specifications; not an official Allen-Bradley datasheet. For an official datasheet, contact Allen-Bradley or an authorized distributor. | ||||||||
Similar Part Numbers |
| ||||||||
Allen Bradley Information | Technical SpecificationsLifecycle status
| ||||||||
Alternate Part Numbers | 20B D027 A3AY NANC0, 2OB DO27-A3AY-NANCO | ||||||||
| Category | PowerFlex 700 | ||||||||
| UPC / GTIN | 0820919088056 | ||||||||
| Part Number | 20BD027A3AYNANC0 | ||||||||
| Manufacturer | Allen-Bradley | ||||||||
Can the 20BD027A3AYNANC0 be repaired?
Yes. NJT Automation repairs the 20BD027A3AYNANC0 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.
NJT managed repair. No evaluation fee; no repair, no charge. Prepaid UPS label both ways, $650 minimum, rush available. 1-year full-function warranty included, 2- and 3-year options.
Prefer an independent shop? Compare bids on RepairMode; providers set their own pricing and warranty.
Find a VFD repair specialiston RepairMode.com ↗Common 20BD027A3AYNANC0 failures
Failure patterns we regularly see on PowerFlex 700 vector control AC drive hardware like the 20BD027A3AYNANC0:
- 20-COMM option or HIM communication faults (DPI port loss)
- Gate driver or current sensor failure showing as erratic current readings
- DC bus capacitor aging: undervoltage trips (F4) or a drive that will not finish precharge
- Precharge relay / circuit failure leaving the drive stuck in precharge
- Hardware overcurrent (F12) or ground fault (F13) from a failed power stage after a motor or cable short
Repair or replace?
Photos by NJT Automation; test videos from NJT or network repair technicians.
Still have questions?
Find answers to shipping, warranties, repairs, and more.