View Cart

Allen-Bradley 25B-D2P5N103 PowerFlex 525 Drive

Allen-Bradley 25B-D2P5N103 PowerFlex 525 Drive. NJT Automation sources the 25B-D2P5N103 on request; send the part number for a replacement or repair quote.

Quote required. Request a quote below for pricing and delivery.

Request Replacement QuoteRequest Repair Quote
Part Number25B-D2P5N103
Price
On Request
Availability and condition determine final quote.
DescriptionAllen-Bradley 25B-D2P5N103 PowerFlex 525 Drive.
Shipping
UPS Ground
Included. Next-Day Air and worldwide shipping available.
Courier
Within 350 miles, est. $3.50/mile, subject to availability.
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price
3 years
+25% of product price
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send us your defective 25B-D2P5N103 after your purchase for a 10% core credit. We also purchase old or damaged parts outright.

Availability
Sourced on request

We do not have a 25B-D2P5N103 on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit.

Sourcing

Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup.

Request QuoteHow Level 1 sourcing works
Repairs

25B-D2P5N103 Mail-In Repair Service

Intended Use

Designed for EtherNet/IP-connected general-purpose variable-speed control applications. PowerFlex 525 drives run conveyors, pumps, fans, mixers and small machines up to 30 Hp, with embedded EtherNet/IP, Safe Torque Off and a removable control module, under a Logix or Micro800 controller.

CategoryPowerFlex 525
Part Number25B-D2P5N103
ManufacturerAllen-Bradley

Can the 25B-D2P5N103 be repaired?

Yes. NJT Automation repairs the 25B-D2P5N103 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.

Option 1

NJT managed repair

Evaluation
Free. No repair, no charge.
Shipping
Prepaid UPS label both ways.
Pricing
$650 minimum. Rush service available.
Warranty
1-year full-function warranty included; 2- and 3-year options.
Get a repair quoteor text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

Find a VFD repair specialiston RepairMode.com ↗

Common Failures

Failure patterns we regularly see on PowerFlex compact drive hardware like the 25B-D2P5N103:

  • Keypad membrane or display failure on the integral keypad
  • Heatsink overtemperature (F008) from a failed fan or blocked airflow
  • Drive will not power up or has a blank display: internal switch-mode power supply failure
  • Power unit fault (F070): IGBT / gate driver failure
  • DC bus undervoltage / overvoltage trips (F004 / F005) from weak incoming power or capacitor aging

Fault code reference

25B-D2P5N103 Fault Codes

43 codes · 520-UM001

Fault codes a PowerFlex 525 AC drive reports on the drive's integral keypad display (F followed by the fault number), as documented in Rockwell Automation publication 520-UM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

25B-D2P5N103 fault codes
CodeFaultWhat it indicates
F002Auxiliary InputThe auxiliary input interlock is open.
F003Power LossExcessive DC bus voltage ripple: incoming phase loss, line imbalance or a blown input fuse.
F004UnderVoltageDC bus voltage fell below the minimum value: low or interrupted incoming line.
F005OverVoltageDC bus voltage exceeded the maximum value: high line, transients or regenerative load with too short a decel time.
F006Motor StalledThe drive is unable to accelerate or decelerate the motor.
F007Motor OverloadInternal electronic motor overload trip.
F008Heatsink OvrTmpHeatsink temperature exceeded the limit: blocked or dirty fins, high ambient or a failed fan.
F009CC OvrTmpControl module temperature exceeded the limit.
F012HW OverCurrentOutput current exceeded the hardware current limit: shorted or grounded motor leads, or a failed power stage.
F013Ground FaultA current path to earth ground was detected at one or more output terminals.
Show 33 more codes
F015Load LossOutput torque current fell below the programmed load-loss level.
F021Output Ph LossOutput phase loss detected (when enabled).
F029Analog In LossAn analog input configured to fault on signal loss has lost its signal.
F033Auto Rstrt TriesThe drive used all programmed auto-restart attempts without clearing the fault.
F038 / F039 / F040Phase U / V / W to GndA phase-to-ground fault was detected between the drive and motor in that phase.
F041 / F042 / F043Phase UV / UW / VW ShortExcessive current was detected between two output terminals.
F048Params DefaultedThe drive was commanded to write default values to EEPROM.
F059Safety OpenBoth safety inputs (Safety 1, Safety 2) are not enabled.
F063SW OverCurrentThe programmed software current trip level was exceeded.
F064Drive OverloadThe drive rating of 150% for 1 minute or 200% for 3 seconds was exceeded.
F070Power UnitA failure was detected in the drive power section.
F071DSI Net LossThe DSI communication network faulted.
F072Opt Net LossThe option-card network faulted.
F073EN Net LossControl through the embedded EtherNet/IP adapter was interrupted.
F080Autotune FailureThe autotune function was cancelled or failed.
F081DSI Comm LossThe RS-485 (DSI) port stopped communicating.
F082Opt Comm LossCommunication with the option card was lost.
F083EN Comm LossCommunication with the embedded EtherNet/IP adapter was lost.
F091Encoder LossEncoder feedback was lost (encoder option card).
F094Function LossThe function-loss input is open.
F100Parameter ChksumThe parameter checksum does not match: reset to defaults and reprogram.
F101External StorageExternal (keypad / USB) storage read or write failed.
F105C Connect ErrThe control module was disconnected from the power module while powered.
F106Incompat C-PThe control module firmware is incompatible with the power module.
F107Replaced C-PThe control module was moved to a different power module; parameters were defaulted.
F109Mismatch C-PThe control module and power module ratings do not match.
F110Keypad MembraneThe keypad membrane failed or a key is stuck.
F111Safety HardwareThe safety input hardware failed.
F114uC FailureMicrocontroller failure.
F122I/O Board FailA failure was detected in the drive control and I/O section.
F125Flash Update ReqA firmware flash update is required.
F126NonRecoverablErrA non-recoverable error occurred.
F127DSIFlashUpdatReqA DSI firmware flash update is required.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 520-UM001, PowerFlex 520-Series Adjustable Frequency AC Drive User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The 25B-D2P5N103 may be available on request in Unused surplus / Refurbished / Used condition. We can quote this part in unused surplus, refurbished, or used condition depending on availability and your preference. Specify your requirement in the RFQ.
The 25B-D2P5N103 is sourced on request. Request a quote and we'll confirm availability and lead time, typically a few business days.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.