View Cart

Allen-Bradley 2711P-T12C4D2 PanelView Plus 12.1-in. Touch – Pickup in Store

In stock: 1 unit in Milwaukee, WI. Physically stocked and ready to ship or available for local pickup. Includes a 1-year full-function warranty.

PanelView Plus 12.1-in. color touch terminal · Ethernet + RS-232 · 24V DC powered

Price

$999.99USDUsedView listing

Request Repair QuoteEstimated $1,295.00
Part Number2711P-T12C4D2
DescriptionPanelView Plus touch terminal, 12.1-in. Touch, 24V DC. In stock in used condition.
Shipping
Ships same or next business day
UPS Ground
Included. Next-Day Air and worldwide shipping available.
Courier
Within 350 miles, est. $3.50/mile, subject to availability.
Pickup
Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954.
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price ($150.00)
3 years
+25% of product price ($250.00)
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send us your defective 2711P-T12C4D2 after your purchase for a 10% core credit. We also purchase old or damaged parts outright.

Replacement Options for 2711P-T12C4D2

Allen Bradley 2711P-T12C4D2 PanelView Plus 1250 Touch 12in 2711PT12C4D2 RDT12C

$999.99 USDIn-stock match

Condition: Used

1 in stockView details
Variants
Part NumberConditionSeriesQtyPrice
2711P-T12C4D2$999.99
Used · 1 in stock
2711P-T12C4D2Used—1$999.99 USD
Availability
1 unit in stock
Repairs

2711P-T12C4D2 Mail-In Repair Service

Estimated: $1,295.00

Part Number Decoder

PanelView Plus touch terminal
2711PT12C4D2
2711P
BulletinPanelView Plus: Allen-Bradley's FactoryTalk View Machine Edition HMI terminal family (PanelView Plus, Plus CE, Plus 6 and Plus 7).
T
Operator inputTouch screen: analog resistive touch, no keypad.
12
Model / size1250 model: 12.1-in. display.
C
Display typeColor display (active-matrix TFT on 700…1500; color STN/TFT on 400/600).
4
CommunicationEthernet, RS-232 and two USB ports: base configuration with the add-on module slot free.
D
Power24V DC power input (18…30V DC).
2
Logic modulePanelView Plus logic module with 128 MB flash / 128 MB RAM (2711P-RP2 class): runs FactoryTalk View ME only.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Series & Revisions

No series in stock today; request a series above.

Modular terminal: the logic module (2711P-RP / RP1 / RP2 on CE 4.1; 2711P-RP8 / RP9 on CE 6.0) sets the OS and the FactoryTalk View ME versions it runs.

Fitting a 2711P-RP8 / RP9 logic module to a Series B or later display is Rockwell's published in-panel upgrade to PanelView Plus 6; Series A display modules are not compatible with those logic modules.

Series notes: Displays of the same size interchange. Read the logic module catalog number and firmware on the back; the series letter alone does not tell you what the terminal can run.

Intended Use

Designed for machine operator interface (HMI) applications. PanelView Plus terminals with a 12.1-in. display are the operator screens on packaging, food and beverage, pharmaceutical, automotive and water equipment, running FactoryTalk View ME applications against Logix, SLC and PLC-5 controllers.

Migration Path

Rockwell Automation has discontinued the original PanelView Plus and PanelView Plus CE terminals. Published successor for the PanelView Plus (Windows CE 4.1): PanelView Plus 7 Performance 2711P-T12W22D9P (12.1-in. wide) with the 2711P-RAAT12 adapter plate.

  • Restore the project into current FactoryTalk View ME from the .apa or .med source, or from a .mer that was saved with conversion allowed, then create a new runtime for the Plus 7 firmware.
  • Cutouts differ. For the 700, 1000, 1250 and 1500 sizes Rockwell's 2711P-RAAT / RAAK adapter plates fit a Plus 7 Performance terminal into the existing opening; the 400/600 move to Plus 7 Standard, which has no adapter plates and needs a new opening.
  • Plus 7 Performance Series B is 24V DC only; AC-powered terminals add a 24V DC supply. Plus 7 has no serial port or network-module slot, so DF1 and 2711P-RN6 (DH+/RIO) / RN3 (DH-485) connections move to EtherNet/IP.
  • In-panel alternative for the modular 700 to 1500 units with a Series B or later display: a surplus 2711P-RP8 / RP9 logic module turns the existing display into a PanelView Plus 6 without touching the cutout. Series A displays are not compatible.

A like-for-like replacement or a repair keeps the existing program, wiring and panel layout; a migration is a project. Both are listed on this page so the choice can be made on lead time and budget.

Physical Data

Weight and DimensionsWeight7.05 lb (3.20 kg)H × W × D11.1 × 14.3 × 2.2 in. (282 × 363 × 55 mm)
Weight3.20 kg (7.05 lb)
Typical unit weight
Dimensions (H × W × D)282 × 363 × 55 mm (11.1 × 14.3 × 2.2 in.)
1250 touch terminal
Shipping Weight5.48 kg (12.1 lb)
Estimated: unit weight plus box and packing material; bills as 13 lb
Shipping Box (L × W × H)26 × 20 × 12 in. (660 × 508 × 305 mm)
Smallest standard box fitting the product with 4 in. cushioning per side
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box.

Similar Part Numbers

  • 2711P-T10C4D2 Model / size: 1000 model
  • 2711P-T15C4D2 Model / size: 1500 model
  • 2711P-T12C6D2 Communication: DH+ / DH-485 / Remote I/O module (2711P-RN6) factory-fitted
  • 2711P-T10C4D1 Model / size: 1000 model; Logic module: PanelView Plus logic module with 64 MB
  • 2711P-T15C4D6 Model / size: 1500 model; Logic module: PanelView Plus CE logic module with 128

Allen Bradley Information

Technical SpecificationsLifecycle status
LifecycleDiscontinued
Verify current status with the manufacturer.
CategoryPanelView Plus
Part Number2711P-T12C4D2
ManufacturerAllen-Bradley
Previously sold 2711P-T12C4D23 sold

NJT Automation has supplied and shipped 3 2711P-T12C4D2 PanelView Plus touch terminals since 2024; these listings are sold and the in-stock options above are ready to ship.

Sold
3 since 2024
Series
A × 2
Allen-Bradley / Rockwell Automation 2711P-T12C4D2 Refurbished - previously sold by NJT AutomationSold

Allen Bradley 2711P-T12C4D2 /A PanelView Plus 1250 Color / 2711P-RP2 F RDT12C C

$1,349.99 USD

Refurbished

Request Quote

Can the 2711P-T12C4D2 be repaired?

Yes. NJT Automation repairs the 2711P-T12C4D2 by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.

Option 1

NJT managed repair

Evaluation
Free. No repair, no charge.
Shipping
Prepaid UPS label both ways.
Pricing
$650 minimum. Rush service available.
Warranty
1-year full-function warranty included; 2- and 3-year options.
Get a repair quoteor text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

Find an HMI repair specialiston RepairMode.com ↗

Common Failures

Failure patterns we regularly see on PanelView Plus touch terminal hardware like the 2711P-T12C4D2:

  • Backlight dim, pink or dark with the terminal still running: aged CCFL tubes or a failed inverter board
  • CompactFlash corruption, or a CF slot that no longer detects the card
  • Touch digitizer unresponsive, drifting or registering ghost touches: worn analog-resistive overlay on the display module
  • Random resets or lockups: failed electrolytic capacitors on the logic module power section
  • Overlay scratched, bubbled or delaminating at the edges

Fault code reference

2711P-T12C4D2 Fault Codes

20 codes · 2711P-UM001

Fault codes a PanelView Plus touch terminal reports on the screen at start-up (error number with an ERROR! message) and the Fault (red) and Comm (green) indicators, as documented in Rockwell Automation publication 2711P-UM001. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

Start-up error messages

2711P-T12C4D2 Start-up error messages
Error #Displayed messageWhat it indicates
1RAM TestRAM test failure. Reset the terminal; if it persists, reseat the SO-DIMM (700…1500). A persistent failure is a logic board fault.
14RAM Header CheckThe OS firmware being downloaded is not compatible with the hardware (400/600 terminals).
20Transfer ImageProgramming the downloaded OS firmware into flash failed (400/600 terminals).
23Download Task / Internal CFFirmware image too large (400/600), or an error programming firmware to the internal CompactFlash (700…1500).
24CRC CheckChecksum of the OS firmware failed; reload firmware. Persistent failures point to the internal CompactFlash or logic module.
25Invalid Prod FamilyThe OS firmware being downloaded is not for this terminal family (400/600 terminals).
27Decompress SystemError decompressing the OS firmware from flash to RAM (400/600 terminals).
30Watchdog TestWatchdog test failure; reload firmware, then suspect the logic module.
31Stuck KeyA function key is held or stuck. Make sure nothing presses on the keypad (on the 400/600, tap F1 rather than holding it to enter Configuration mode) and reset; persistent failures mean the keypad / display module.
31.5Stuck TouchTouch screen reports a constant touch (700…1500 terminals). Remove anything pressing on the screen, including a damaged anti-glare overlay, and reset; persistent failures mean the display module.
Show 5 more codes
32Battery TestBattery failure (700…1500 terminals). Fit a new battery; if it persists, the fault is on the logic module.
33.5NVRAM AccessNonvolatile memory failure (700…1500 terminals); upgrade system firmware to 3.10.03 or later.
3aStuck TouchTouch screen reports a constant touch (400/600 terminals). Remove anything pressing on the screen, including a damaged anti-glare overlay, and reset; persistent failures mean the terminal.
40EXE CheckSystem OS firmware is missing or corrupt; reload firmware.
50External CFError loading OS firmware from the external CompactFlash card.

Status indicator states if the terminal stops during start-up

2711P-T12C4D2 Status indicator states if the terminal stops during start-up
IndicatorsStateWhat it indicates
Fault blinking · Comm offLast firmware download failedRecoverable: reload the firmware with the Firmware Upgrade Wizard.
Fault blinking · Comm blinkingBoot loader firmware failed or missingRecoverable: reload the firmware with the Firmware Upgrade Wizard.
Fault blinking · Comm onWindows CE OS firmware failed or missingRecoverable: reload the firmware with the Firmware Upgrade Wizard.
Fault on · Comm offFatal hardware errorHardware fault in the logic module (700…1500) or the terminal's logic board (400/600).
Fault on · Comm blinkingFatal hardware error in displayHardware fault in the display module (700…1500) or the terminal's display section (400/600).

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 2711P-UM001, PanelView Plus Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 2711P-T12C4D2 is a PanelView Plus 12.1-in. color touch terminal, Ethernet + RS-232, 24V DC powered.
NJT Automation currently has 1 unit of the 2711P-T12C4D2 in stock in used condition. Each listing states its own condition and series. Used means a unit removed from service and sold without refurbishment. Cosmetic condition, any functional testing performed, and the warranty term are stated on each unit’s own listing. From the listing: This item is in good working condition with some signs of use and is fully functional. It comes with 90-day free returns and a 1 year NJT warranty.
The 2711P-T12C4D2 starts at $999.99 (Used) at NJT Automation. One unit is in stock. 3 2711P-T12C4D2 PanelView Plus touch terminals have sold since 2024.
1 unit of the 2711P-T12C4D2 PanelView Plus touch terminal are on the shelf in Milwaukee, WI, priced from $999.99. Orders before 5:00 PM Central on a business day ship the same day; next-day air is available at checkout.
24V DC power input (18…30V DC).
Touch screen: analog resistive touch, no keypad.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.