Allen-Bradley 2711P · Fault code reference

PanelView Plus Fault Codes

Every fault code a PanelView Plus reports on the screen at start-up (error number with an ERROR! message) and the Fault (red) and Comm (green) indicators, with what each one indicates, as documented in Rockwell Automation publication 2711P-UM001.

20 codes · 2711P-UM001 · 467 part numbers covered

PanelView Plus fault code list

Start-up error messages

PanelView Plus Start-up error messages
Error #Displayed messageWhat it indicates
1RAM TestRAM test failure. Reset the terminal; if it persists, reseat the SO-DIMM (700…1500). A persistent failure is a logic board fault.
14RAM Header CheckThe OS firmware being downloaded is not compatible with the hardware (400/600 terminals).
20Transfer ImageProgramming the downloaded OS firmware into flash failed (400/600 terminals).
23Download Task / Internal CFFirmware image too large (400/600), or an error programming firmware to the internal CompactFlash (700…1500).
24CRC CheckChecksum of the OS firmware failed; reload firmware. Persistent failures point to the internal CompactFlash or logic module.
25Invalid Prod FamilyThe OS firmware being downloaded is not for this terminal family (400/600 terminals).
27Decompress SystemError decompressing the OS firmware from flash to RAM (400/600 terminals).
30Watchdog TestWatchdog test failure; reload firmware, then suspect the logic module.
31Stuck KeyA function key is held or stuck. Make sure nothing presses on the keypad (on the 400/600, tap F1 rather than holding it to enter Configuration mode) and reset; persistent failures mean the keypad / display module.
31.5Stuck TouchTouch screen reports a constant touch (700…1500 terminals). Remove anything pressing on the screen, including a damaged anti-glare overlay, and reset; persistent failures mean the display module.
32Battery TestBattery failure (700…1500 terminals). Fit a new battery; if it persists, the fault is on the logic module.
33.5NVRAM AccessNonvolatile memory failure (700…1500 terminals); upgrade system firmware to 3.10.03 or later.
3aStuck TouchTouch screen reports a constant touch (400/600 terminals). Remove anything pressing on the screen, including a damaged anti-glare overlay, and reset; persistent failures mean the terminal.
40EXE CheckSystem OS firmware is missing or corrupt; reload firmware.
50External CFError loading OS firmware from the external CompactFlash card.

Status indicator states if the terminal stops during start-up

PanelView Plus Status indicator states if the terminal stops during start-up
IndicatorsStateWhat it indicates
Fault blinking · Comm offLast firmware download failedRecoverable: reload the firmware with the Firmware Upgrade Wizard.
Fault blinking · Comm blinkingBoot loader firmware failed or missingRecoverable: reload the firmware with the Firmware Upgrade Wizard.
Fault blinking · Comm onWindows CE OS firmware failed or missingRecoverable: reload the firmware with the Firmware Upgrade Wizard.
Fault on · Comm offFatal hardware errorHardware fault in the logic module (700…1500) or the terminal's logic board (400/600).
Fault on · Comm blinkingFatal hardware error in displayHardware fault in the display module (700…1500) or the terminal's display section (400/600).

Is it a hardware fault?

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part, not at wiring, configuration or the application. Those are the faults NJT Automation repairs at component level. A repair is usually cheaper and faster than a replacement for an obsolete PanelView Plus unit; each part number below links to its stock, repair pricing and test videos.

Faults are read from the screen at start-up (error number with an ERROR! message) and the Fault (red) and Comm (green) indicators.

Source

Codes are listed as documented. Fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series. Spotted an error? Tell us and we will correct it.

Related references

PanelView Plus part numbers these codes apply to

467 catalog numbers, 36 in stock now. Each links to stock, condition, repair pricing and series notes for that catalog number.

Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.