View Cart

Allen-Bradley 2711P-K4M20A8 PanelView Plus 6 – Repair Service Available

Allen-Bradley 2711P-K4M20A8 PanelView Plus 6 3.5-in. monochrome / grayscale keypad terminal, Ethernet + RS-232, AC powered. NJT Automation offers mail-in repair for the 2711P-K4M20A8 with a 1-year warranty; replacement pricing is available on request.

Mail-in repair available now. Returned with a 1-year warranty. Replacement pricing on request.

Request Replacement QuoteRequest Repair QuoteEstimated $1,295.00
Part Number2711P-K4M20A8
Price
On Request
Previously sold for $1,799.99 - $2,819.99 USDAvailability and condition determine final quote.
DescriptionPanelView Plus 6 keypad terminal, 3.5-in. Keypad, 264V AC.
Shipping
UPS Ground
Included. Next-Day Air and worldwide shipping available.
Courier
Within 350 miles, est. $3.50/mile, subject to availability.
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price ($346.50)
3 years
+25% of product price ($577.50)
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send in your defective 2711P-K4M20A8 for a 10% core credit.

Availability
Sourced on RequestIndependently SourcedNot an OEM-Authorized Distributor

We do not have a 2711P-K4M20A8 on the shelf right now. We can source one through our supplier network; request a quote and we confirm availability, price and lead time before you commit.

Sourcing

Sourced through our Level 1 network of vetted US suppliers. Each unit is checked before it ships and carries the same NJT warranty and return policy as our own stock. Quotes within one hour during business hours; typical delivery 3–5 business days, next-day air available. Sourced parts are not available for local pickup.

Request QuoteHow Level 1 sourcing works
Repairs

2711P-K4M20A8 Mail-In Repair Service

Estimated: $1,295.00

Part Number Decoder

PanelView Plus 6 keypad terminal
2711PK4M20A8
2711P
BulletinPanelView Plus: Allen-Bradley's FactoryTalk View Machine Edition HMI terminal family (PanelView Plus, Plus CE, Plus 6 and Plus 7).
K
Operator inputKeypad: function keys and numeric keypad, no touch screen.
4
Model / size400 model: 3.5-in. display.
M
Display typeMonochrome / grayscale display (400 and 600 models only).
20
CommunicationEthernet (10/100 Mbps) and RS-232 serial, one USB host and one USB device port; add-on modules not supported.
A
PowerAC power input, 85…264V AC (100…240V AC nominal).
8
Operating system / featuresWindows CE 6.0 with standard features (FTP, VNC, ActiveX), without the extended features or Microsoft Office file viewers.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Series & Revisions

No series in stock today; request a series above.

Series notes: Same cutout and connections across series; confirm the replacement's firmware supports the project's FactoryTalk View ME version.

Intended Use

Intended for machine operator interface (HMI) applications. PanelView Plus terminals with a 3.5-in. display are the operator screens on packaging, food and beverage, pharmaceutical, automotive and water equipment, running FactoryTalk View ME applications against Logix, SLC and PLC-5 controllers. Keypad models suit gloved operators and washdown areas where a touchscreen is impractical.

Physical Data

Weight and DimensionsWeight1.04 lb (0.47 kg)H × W × D6 × 7.3 × 2.4 in. (152 × 185 × 60 mm)
Weight0.47 kg (1.04 lb)
Typical unit weight
Dimensions (H × W × D)152 × 185 × 60 mm (6 × 7.3 × 2.4 in.)
400 keypad / keypad + touch terminal, DC
Shipping Weight1.19 kg (2.63 lb)
Estimated: unit weight plus box and packing material; bills as 3 lb
Shipping Box (L × W × H)14 × 12 × 10 in. (356 × 305 × 254 mm)
Smallest standard box fitting the product with 3 in. cushioning per side
Product weight and dimensions are typical manufacturer-published values and may differ by series or option. Shipping box and weight are estimates for freight planning; the packed unit may ship in a different box.

Similar Part Numbers

  • 2711P-K4M20D8 Power: 24V DC power input (18…30V DC)
  • 2711P-K4C20D8 Display type: Color display; Power: 24V DC power input (18…30V DC)

Allen-Bradley Information

Technical SpecificationsLifecycle status
LifecycleDiscontinued
Verify current status with the manufacturer.
CategoryPanelView Plus
Part Number2711P-K4M20A8
ManufacturerAllen-Bradley

Previously sold 2711P-K4M20A8

2 sold

NJT Automation has supplied and shipped 2 2711P-K4M20A8 PanelView Plus 6 keypad terminals since 2025; request a quote and we will source another from our supplier network.

Sold
2 since 2025
Series
A × 2
Allen-Bradley 2711P-K4M20A8 Used - previously sold by NJT AutomationSold

Allen-Bradley 2711P-K4M20A8 PanelView Plus 400 Operator Interface Panel

$2,819.99 USD

Used

Request Quote

Can the 2711P-K4M20A8 be repaired?

Yes. NJT Automation repairs the 2711P-K4M20A8 by mail-in: diagnostic evaluation, component-level repair and a functional test.

Option 1

NJT Managed Repair

Evaluation
Free evaluation.
Shipping
Free UPS shipping both ways, including unrepairable returns. Local drop-off and pickup available.
Pricing
$650 minimum for successful repairs.
Warranty
1-year full-function warranty included. 2- and 3-year options available.
Get a repair quoteOr text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

View completed 2711P-K4M20A8 repairson RepairMode.com ↗

Common Failures

Failure patterns we regularly see on PanelView Plus 6 keypad terminal hardware like the 2711P-K4M20A8:

  • Real-time clock resetting: depleted coin cell
  • Lines, dead pixels or low contrast on the LCD
  • Hangs on the splash screen: control board flash or firmware corruption
  • Backlight dim or dark with the terminal still running: aged CCFL or a failed inverter board
  • Membrane keypad wear: function keys or numeric keys not responding, or a stuck-key fault at power-up

Fault code reference

2711P-K4M20A8 Fault Codes

19 codes · 2711P-UM006

Fault codes a PanelView Plus 6 keypad terminal reports on the start-up splash screen (shown as Fatal followed by a two-character code, for example Fatal 3A) and the Fault (red) and Comm (green) indicators, as documented in Rockwell Automation publication 2711P-UM006. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

Fatal start-up codes

2711P-K4M20A8 Fatal start-up codes
CodeFailureWhat it indicates
Fatal 02Watch dog resetA momentary loss of control due to a software failure. The terminal halts at the maintenance window; monitor for recurrence.
Fatal 03Failed RAMPOST failure in the terminal's RAM; a hardware fault in the logic module (700…1500) or the terminal's logic board (400/600).
Fatal 0FFirmware update failureFatal during firmware loading. Reset from the maintenance menu, restore factory defaults or reinstall firmware.
Fatal 1EFirmware validation (CRC/format) failureFatal during firmware loading (1E also appears as a normal 'Update' progress code). Reset, restore defaults or reinstall firmware.
Fatal 1FFirmware compatibility index failureFirmware failed to validate the compatibility index of a firmware region; reinstall the correct firmware.
Fatal 31Stuck keyPOST found a function key held or stuck. Make sure nothing presses on the keypad and reset the terminal without touching any key; if it persists, the fault is in the keypad / display module.
Fatal 3AStuck touchPOST found a touch cell held or stuck. Make sure nothing is pressing on the screen (including a damaged anti-glare overlay), then reset without touching it; if it persists, the fault is in the touch screen / display module.
Fatal 3BFailed backlightPOST could not start the backlight; a hardware fault in the display module. If 3A or 3B appears right after an LED-backlit (newer series) display module was fitted to an older logic module, check the logic module firmware first (2711P-IN030 requires 7.00.20 or later for LED displays on Plus 6).
Fatal A5Firmware write to storage failureFatal during firmware loading (A5 also appears as a normal 'Update/Restore' progress code). Reset, restore defaults or reinstall firmware.
Fatal D2Firmware stored image verification failureFatal during firmware loading; reset, restore defaults or reinstall firmware.
Show 6 more codes
Fatal FFInvalid or missing OS firmware imageNo valid operating system image (FF also appears as a normal 'AutoTest' progress code). Reinstall firmware.
Fatal R0Failed to initialize restore operationFatal during a restore; reset the terminal from the maintenance menu.
Fatal R1Invalid header in .pvb fileFatal during a restore; the backup file header is invalid.
Fatal R2Invalid headerFatal during a restore.
Fatal R3Cannot write intermediate filesFatal during a restore; the terminal could not write intermediate files.
Fatal R4Corrupt .pvb fileFatal during a restore; the backup file is corrupt.

The splash screen shows the state word and the code together, for example "Fatal 3A". Codes shown with the state AutoTest, Boot, Init, Update or Restore (E6, FF, G0, H1–JA, K1–MA, 1E, A5, DC) are normal progress messages; only codes shown with the state Fatal are errors. Rockwell Knowledgebase 459615 reproduces this list.

Status indicator states if the terminal stops during start-up

2711P-K4M20A8 Status indicator states if the terminal stops during start-up
IndicatorsStateWhat it indicates
Fault blinking · Comm offRecoverable firmware errorLast firmware download failed. Reload the firmware with the Firmware Upgrade Wizard.
Fault on · Comm offNon-recoverable logic module faultHardware fault in the logic module (700…1500) or the terminal's logic board (400/600); not recoverable by a reset or firmware reload.
Fault on · Comm blinkingNon-recoverable display module faultHardware fault in the display module (700…1500) or the terminal's display section (400/600); not recoverable by a reset or firmware reload.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 2711P-UM006, PanelView Plus 6 Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Functional test video

Bench test from a completed 2711P-K4M20A8 repair.

RepairMode test video for 2711P-K4M20A8

Open the test video page

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 2711P-K4M20A8 is a PanelView Plus 6 3.5-in. monochrome / grayscale keypad terminal, Ethernet + RS-232, AC powered.
The 2711P-K4M20A8 may be available on request in Unused surplus / Refurbished / Used condition. We can quote this part in unused surplus, refurbished, or used condition depending on availability and your preference. Specify your requirement in the RFQ.
At NJT Automation, 2 2711P-K4M20A8 PanelView Plus 6 keypad terminals have sold since 2025 for $1,800 – $2,820. None are in stock at the moment; request a quote for current pricing, or have your PanelView Plus 6 keypad terminal repaired by NJT Automation (see the repair section on this page).
The 2711P-K4M20A8 is sourced on request. Request a quote and we'll confirm availability and lead time, typically a few business days.
AC power input, 85…264V AC (100…240V AC nominal).
Keypad: function keys and numeric keypad, no touch screen.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.