View Cart

Allen-Bradley 2711P-RP8D PanelView Plus 6 512 MB – Pickup in Store

In stock: 4 units in Milwaukee, WI. Physically stocked and ready to ship or available for local pickup. Includes a 1-year full-function warranty.

PanelView Plus 6 logic module for 700…1500 terminals · 512 MB RAM · Windows CE 6.0 standard features · DC powered

Starting at

$449.99USDUsed, Series AView listing

Used, unused surplus and refurbished options available below

Request Repair Quote
Part Number2711P-RP8D
DescriptionPanelView Plus 6 logic module, 512 MB, 24V DC. In stock in used and unused surplus condition, Series A and B.
Shipping
Ships same or next business day
UPS Ground
Included. Next-Day Air and worldwide shipping available.
Courier
Within 350 miles, est. $3.50/mile, subject to availability.
Pickup
Free local pickup at 2122 N Prospect Ave. Call ahead at (414) 331-5954.
Warranty
1-year full-function warranty provided by NJT Automation.
Warranty details
Included
1 year, full-function
2 years
+15% of product price (from $67.50)
3 years
+25% of product price (from $112.50)
View full warranty policy
Returns
90-day free returns. View return policy
Exchange

Send us your defective 2711P-RP8D after your purchase for a 10% core credit. We also purchase old or damaged parts outright.

Replacement Options for 2711P-RP8D

Allen Bradley 2711P-RP8D /A PanelView Plus Logic Module 128MB RAM 24V 2711PRP8D

$449.99 USDIn-stock match

Condition: Used

Series A

1 in stockView details

Allen Bradley 2711P-RP8D /B PanelView Plus Logic Module 128MB 2711PRP8D AB Reman

$3,499.99 USDIn-stock match

Condition: Unused surplus (open box)

Series B

1 in stockView details
Variants
Part NumberConditionSeriesQtyPrice
2711P-RP8D /A$449.99
Used · Series A · 1 in stock
2711P-RP8D /AUsedSeries A1$449.99 USD
2711P-RP8D /B$3,499.99
Unused surplus (open box) · Series B · 1 in stock
2711P-RP8D /BUnused surplus (open box)Series B1$3,499.99 USD
2711P-RP8D /A$3,999.99
Unused surplus (open box) · Series A · 1 in stock
2711P-RP8D /AUnused surplus (open box)Series A1$3,999.99 USD
2711P-RP8D/A$549.99
Refurbished · Series A · 1 in stock
2711P-RP8D/ARefurbishedSeries A1$549.99 USD

2711P-RP8D

Refurbished — pick series, then request a quote

Request Quote
2711P-RP8DRefurbished—Request Quote
Availability
4 units in stock
Repairs

2711P-RP8D Mail-In Repair Service

Part Number Decoder

PanelView Plus 6 logic module
2711PRP8D
2711P
BulletinPanelView Plus: Allen-Bradley's FactoryTalk View Machine Edition HMI terminal family (PanelView Plus, Plus CE, Plus 6 and Plus 7).
RP
Module typeReplacement logic module: the processor/memory unit that attaches to the rear of a 700…1500 display module.
8
Platform / memoryPanelView Plus 6, 512 MB RAM, Windows CE 6.0 standard features.
D
Power input24V DC power input.
Decoded from the Rockwell Automation catalog-number structure. Series and firmware revision are printed on the product label, not encoded here.

Series & Revisions

Series A and B in stock; other series on request.

Intended Use

Intended for machine operator interface (HMI) applications. The logic module is the computer behind a PanelView Plus terminal, running the FactoryTalk View ME application that operators use to monitor and run packaging, process and assembly equipment.

Physical Data

Weight and DimensionsBox12 × 10 × 8 in.
Shipping Box (L × W × H)12 × 10 × 8 in. (305 × 254 × 203 mm)
Most common box recorded for this catalog number
Shipping box and weight are recorded from previous shipments of this catalog number and are provided for freight planning.

Similar Part Numbers

  • 2711P-RP1 Platform / memory: PanelView Plus, 64 MB flash / 64 MB RAM; Power input: Non-isolated 24V DC power input
  • 2711P-RP1A Platform / memory: PanelView Plus, 64 MB flash / 64 MB RAM; Power input: AC power input
  • 2711P-RP2 Platform / memory: PanelView Plus, 128 MB flash / 128 MB; Power input: Non-isolated 24V DC power input

Allen Bradley Information

Technical Specifications6 parameters from manufacturer-published specifications
Module typePanelView Plus 6 logic module (700…1500 terminals)
Memory512 MB RAM; 512 MB nonvolatile storage
Input power24V DC nominal (18…32V DC); 70 W max (2.9 A), 39 W typical
Power input typeIsolated DC
Communication1 × Ethernet 10/100 Mbps; 1 × RS-232; 2 × USB host; 1 × SD slot; slot for optional communication module
SoftwareFactoryTalk View Machine Edition v6.0 or later; Windows CE 6.0
Typical manufacturer-published values for this catalog number; confirm against the current manufacturer documentation before specifying.
CategoryPanelView Plus
UPC / GTIN0612598876877
Part Number2711P-RP8D
ManufacturerAllen-Bradley
Previously sold 2711P-RP8D9 sold · +4 on eBay

NJT Automation has supplied and shipped 9 2711P-RP8D PanelView Plus 6 logic modules since 2025; these listings are sold and the in-stock options above are ready to ship.

Sold
9 since 2025
Series
B × 6, A × 3
Allen-Bradley 2711P-RP8D Unused surplus (open box) - previously sold by NJT AutomationSold

Allen Bradley 2711P-RP8D /B PanelView Plus Logic Module - Without Original Box

$2,849.99 USD

Unused surplus (open box)

Request Quote
4 sold on eBay

Can the 2711P-RP8D be repaired?

Yes. NJT Automation repairs the 2711P-RP8D by mail-in: diagnostic evaluation, component-level repair and a functional test, backed by a 1-year full-function warranty.

Option 1

NJT managed repair

Evaluation
Free. No repair, no charge.
Shipping
Prepaid UPS label both ways.
Pricing
$650 minimum. Rush service available.
Warranty
1-year full-function warranty included; 2- and 3-year options.
Get a repair quoteor text photos and symptoms to (414) 331-5954

Option 2

Independent repair bids. Compare quotes from independent repair technicians. Post your repair on RepairMode to receive competitive bids from experienced technicians. Each technician sets their own pricing and warranty.

View completed 2711P-RP8D repairson RepairMode.com ↗

Common Failures

Failure patterns we regularly see on PanelView Plus 6 logic module hardware like the 2711P-RP8D:

  • Random resets or lockups under load: failed electrolytic capacitors on the power supply section of the logic board
  • Will not boot or hangs on the splash screen: control board DRAM, flash or firmware failure
  • Overheating in a sealed enclosure: thermal shutdown, then capacitor and solder-joint fatigue
  • Communication module slot not recognizing a 2711P-RN card
  • Display module connector pins bent or worn from repeated separation

Fault code reference

2711P-RP8D Fault Codes

19 codes · 2711P-UM006

Fault codes a PanelView Plus 6 logic module reports on the start-up splash screen (shown as Fatal followed by a two-character code, for example Fatal 3A) and the Fault (red) and Comm (green) indicators, as documented in Rockwell Automation publication 2711P-UM006. Use them to narrow a problem down to the unit, its wiring or the application before sending it in for repair.

Fatal start-up codes

2711P-RP8D Fatal start-up codes
CodeFailureWhat it indicates
Fatal 02Watch dog resetA momentary loss of control due to a software failure. The terminal halts at the maintenance window; monitor for recurrence.
Fatal 03Failed RAMPOST failure in the terminal's RAM; a hardware fault in the logic module (700…1500) or the terminal's logic board (400/600).
Fatal 0FFirmware update failureFatal during firmware loading. Reset from the maintenance menu, restore factory defaults or reinstall firmware.
Fatal 1EFirmware validation (CRC/format) failureFatal during firmware loading (1E also appears as a normal 'Update' progress code). Reset, restore defaults or reinstall firmware.
Fatal 1FFirmware compatibility index failureFirmware failed to validate the compatibility index of a firmware region; reinstall the correct firmware.
Fatal 31Stuck keyPOST found a function key held or stuck. Make sure nothing presses on the keypad and reset the terminal without touching any key; if it persists, the fault is in the keypad / display module.
Fatal 3AStuck touchPOST found a touch cell held or stuck. Make sure nothing is pressing on the screen (including a damaged anti-glare overlay), then reset without touching it; if it persists, the fault is in the touch screen / display module.
Fatal 3BFailed backlightPOST could not start the backlight; a hardware fault in the display module. If 3A or 3B appears right after an LED-backlit (newer series) display module was fitted to an older logic module, check the logic module firmware first (2711P-IN030 requires 7.00.20 or later for LED displays on Plus 6).
Fatal A5Firmware write to storage failureFatal during firmware loading (A5 also appears as a normal 'Update/Restore' progress code). Reset, restore defaults or reinstall firmware.
Fatal D2Firmware stored image verification failureFatal during firmware loading; reset, restore defaults or reinstall firmware.
Show 6 more codes
Fatal FFInvalid or missing OS firmware imageNo valid operating system image (FF also appears as a normal 'AutoTest' progress code). Reinstall firmware.
Fatal R0Failed to initialize restore operationFatal during a restore; reset the terminal from the maintenance menu.
Fatal R1Invalid header in .pvb fileFatal during a restore; the backup file header is invalid.
Fatal R2Invalid headerFatal during a restore.
Fatal R3Cannot write intermediate filesFatal during a restore; the terminal could not write intermediate files.
Fatal R4Corrupt .pvb fileFatal during a restore; the backup file is corrupt.

The splash screen shows the state word and the code together, for example "Fatal 3A". Codes shown with the state AutoTest, Boot, Init, Update or Restore (E6, FF, G0, H1–JA, K1–MA, 1E, A5, DC) are normal progress messages; only codes shown with the state Fatal are errors. Rockwell Knowledgebase 459615 reproduces this list.

Status indicator states if the terminal stops during start-up

2711P-RP8D Status indicator states if the terminal stops during start-up
IndicatorsStateWhat it indicates
Fault blinking · Comm offRecoverable firmware errorLast firmware download failed. Reload the firmware with the Firmware Upgrade Wizard.
Fault on · Comm offNon-recoverable logic module faultHardware fault in the logic module (700…1500) or the terminal's logic board (400/600); not recoverable by a reset or firmware reload.
Fault on · Comm blinkingNon-recoverable display module faultHardware fault in the display module (700…1500) or the terminal's display section (400/600); not recoverable by a reset or firmware reload.

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part. Those are the faults NJT Automation repairs at component level, so a repair quote is usually the first thing to check before buying a replacement.

Source: Rockwell Automation publication 2711P-UM006, PanelView Plus 6 Terminals User Manual. Codes are listed as documented; fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series.

Functional test video

Bench test from a completed 2711P-RP8D repair.

RepairMode test video for 2711P-RP8D

Open the test video page

Photos by NJT Automation; test videos from NJT or network repair technicians.

Still have questions?

Find answers to shipping, warranties, repairs, and more.

The Allen-Bradley 2711P-RP8D is a PanelView Plus 6 logic module for 700…1500 terminals, 512 MB RAM, Windows CE 6.0 standard features, DC powered.
NJT Automation currently has 4 units of the 2711P-RP8D in stock in used, unused surplus and refurbished condition (Series A and B). Each listing states its own condition and series. Used means a unit removed from service and sold without refurbishment. Cosmetic condition, any functional testing performed, and the warranty term are stated on each unit’s own listing.
The 2711P-RP8D starts at $449.99 (Used, Series A) at NJT Automation. 4 units are in stock; other conditions and series are priced individually in the options above. 9 2711P-RP8D PanelView Plus 6 logic modules have sold since 2025.
4 units of the 2711P-RP8D PanelView Plus 6 logic module are on the shelf in Milwaukee, WI, priced from $449.99. Orders before 5:00 PM Central on a business day ship the same day; next-day air is available at checkout.
24V DC power input.
PanelView Plus 6, 512 MB RAM, Windows CE 6.0 standard features.
Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.