Allen-Bradley Series Letters Explained
Every Allen-Bradley label carries a series letter, and buyers often treat a different letter as a different part. For most families it is not: the software keys on catalog number and firmware revision. For a few it marks a real platform change. This page sets out, family by family, what the letter means and whether one series can stand in for another.
Series comparisons
- PanelView Plus 7 Performance Series A vs Series BPanelView Plus 7 Performance Series A vs B (and stainless-steel Series C): operating system, RAM, FactoryTalk View ME firmware, power and whether one series can replace the other.
- ControlLogix Controller Series Differences: L1, L55, L6x, L7x and 5580What the series letter changes on ControlLogix 1756-L1, L55, L61–L65 (Series A vs B battery), L71–L75 and 5580 L8xE controllers, and how Studio 5000 treats a different series.
- SLC 500 Processor Series A vs B vs C (5/03, 5/04, 5/05)Operating system (OS/FRN) by series for SLC 5/03 (1747-L53x), SLC 5/04 (1747-L54x) and SLC 5/05 (1747-L55x) processors, the Series C 10/100 Ethernet port, and series-to-series replacement rules.
- PanelView Plus and Plus 6 Logic Modules: What the Display Series MeansHow the logic module (2711P-RP, RP1, RP2, RP8, RP9) sets the operating system and FactoryTalk View ME version on modular PanelView Plus and PanelView Plus 6 700–1500 terminals, and which display series take the Plus 6 upgrade.
- Kinetix 6000 vs Kinetix 6200 / 6500: The -S and -M SuffixWhy 2094 Kinetix 6000 (-S, SERCOS) and Kinetix 6200 / 6500 (-M) modules look alike but do not interchange on a power rail, and how to replace a 2094 drive within the same catalog number.
- Kinetix 300 vs Kinetix 350: Indexing Drive vs Integrated MotionKinetix 300 (2097-V3xPRy) and Kinetix 350 (2097-V3xPRy-LM) share a frame and power ratings but are controlled differently. How to tell them apart, how each is configured and whether one can replace the other.
By family
SLC 5/05 processors (1747-L55x)
Series A shipped with OS500 and can be flashed to OS501; Series B and C ship with OS501. Only Series C hardware has the 10/100 Mbps Ethernet port; A and B run 10 Mbps half duplex.
Interchange: Same slot and wiring. A later series runs an earlier program; an earlier series rejects a program that uses newer OS/FRN features.
Rockwell Automation 1747-UM011 · SLC 500 Processor Series A vs B vs C (5/03, 5/04, 5/05)
SLC 5/03 processors (1747-L53x)
Series A shipped with OS300, Series B with OS301 and Series C with OS302; earlier units take the 1747-OS302 upgrade cartridge.
Interchange: Same slot and wiring. A later series runs an earlier program; match or exceed the OS/FRN of the unit being replaced.
Rockwell Automation 1747-UM011 · SLC 500 Processor Series A vs B vs C (5/03, 5/04, 5/05)
SLC 5/04 processors (1747-L54x)
Series A shipped with OS400, later series with OS401; the 1747-OS401 cartridge upgrades earlier units.
Interchange: Same slot and wiring. A later series runs an earlier program; a program that needs OS401 will not load on Series A.
Rockwell Automation 1747-UM011 · SLC 500 Processor Series A vs B vs C (5/03, 5/04, 5/05)
Other SLC 500 processors (1747-L)
Interchange: A later series runs the existing program; an earlier one may not if the program uses newer instructions. RSLogix 500 keys on catalog number and OS/FRN, not series.
Rockwell Automation 1747-UM011
SLC 500 I/O modules (1746)
Interchange: RSLogix 500 configures 1746 I/O by catalog number only; any series fits the same slot and wiring.
Rockwell Automation 1746-UM001
PLC-5 processors (1785-L)
PLC-5 labels carry a series letter and a revision letter; later ones add firmware features under the same catalog number.
Interchange: Same slot and DH+ / Remote I/O wiring. Match or exceed the series/revision of the unit being replaced so the program loads.
Rockwell Automation 1785-UM012
ControlLogix 1756-L1 and L55 controllers
All series use the 1756-BA1 battery; on the L55 the memory board (1756-M1x/M2x) is part of the catalog number.
Interchange: RSLogix 5000 keys on catalog number and firmware revision, not series; flash the replacement to the project's revision.
Rockwell Automation 1756-UM001 · ControlLogix Controller Series Differences: L1, L55, L6x, L7x and 5580
ControlLogix 1756-L61 to L65 controllers
Series A uses the 1756-BA1 battery; Series B uses the 1756-BA2. Firmware files are the same for both.
Interchange: Studio 5000 keys on catalog number and firmware revision, not series; fit the correct battery for the series.
Rockwell Automation 1756-UM001 · ControlLogix Controller Series Differences: L1, L55, L6x, L7x and 5580
ControlLogix 1756-L71 to L75 controllers
All series use the 1756-ESMCAP energy-storage module and a 1784-SD1 / SD2 card; no battery.
Interchange: Studio 5000 keys on catalog number and firmware revision, not series.
Rockwell Automation 1756-UM001 · ControlLogix Controller Series Differences: L1, L55, L6x, L7x and 5580
ControlLogix and GuardLogix 5580 controllers (1756-L8xE)
Series B controllers run firmware revision 31.011 or later; Series A units also run the earlier 5580 revisions (28 to 30).
Every series needs a Series B or Series C 1756 chassis (Series B derated to 50 °C ambient); 5580 controllers do not work in a Series A chassis.
Interchange: Studio 5000 keys on catalog number and firmware revision, not series. Fitting a Series B into a project on revision 28 to 30 means upgrading the project to 31 or later first.
Rockwell Automation 1756-UM543, 1756-TD001, Product Compatibility and Download Center · ControlLogix Controller Series Differences: L1, L55, L6x, L7x and 5580
ControlLogix I/O and communication modules (1756)
Interchange: Logix keys on catalog number and firmware revision, not series; with the default Compatible Module keying, any series of the same catalog number is accepted in the slot.
Rockwell Automation 1756-UM001
CompactLogix, Compact I/O, POINT I/O and FLEX I/O (1769, 5069, 1734, 1794, 5094)
Interchange: Logix keys on catalog number and firmware revision, not series; with the default Compatible Module keying, any series of the same catalog number is accepted in the slot.
Rockwell Automation 1756-PM004 (Electronic Keying)
MicroLogix processors (1761, 1762, 1763, 1764, 1766)
Interchange: A later series runs the existing program after the processor type is changed in RSLogix 500. An earlier series may not if the program uses features from a newer OS/FRN.
Rockwell Automation MicroLogix user manuals
PanelView Plus 7 Performance, stainless steel (-BSHK)
Series A and B (stainless steel): Windows CE 6.0, 512 MB RAM, firmware up to v12.
Series C: Windows 10 IoT Core, 4 GB RAM, firmware v12 and later; no Windows desktop or Remote Desktop client (VNC remote access remains).
All stainless-steel models are 24V DC.
Interchange: Series C terminals may replace Series A or B terminals in compatible applications, but differences in operating systems, firmware, and supported features must be evaluated before replacement. Existing FactoryTalk View ME applications may require updates or modifications. An A or B can stand in for a Series C only if the runtime is saved for ME v12; their firmware stops there, so a project saved in ME v13 or later will not load.
Rockwell Automation 2711P-UM008 · PanelView Plus 7 Performance Series A vs Series B
PanelView Plus 7 Performance terminals
Series A: Windows CE 6.0, 512 MB RAM, firmware up to v12.
Series B: Windows 10 IoT Core, 4 GB RAM, firmware v12 and later; no Windows desktop or Remote Desktop client (VNC remote access remains).
AC-powered models exist as Series A only; Series B is 24V DC.
Interchange: Series B terminals may replace Series A terminals in compatible applications, but differences in operating systems, firmware, and supported features must be evaluated before replacement. Existing FactoryTalk View ME applications may require updates or modifications. A Series A can stand in for a Series B only if the runtime is saved for ME v12; its firmware stops there, so a project saved in ME v13 or later will not load.
Rockwell Automation 2711P-UM008, 2711P-QS002 · PanelView Plus 7 Performance Series A vs Series B
PanelView Plus 6 700 to 1500 terminals
700 to 1500 terminals are modular: the 2711P-RP8 / RP9 logic module, not the display, carries the OS and firmware.
Interchange: Displays of the same size interchange across series. Match or exceed the logic module's firmware so the existing .mer runs.
Rockwell Automation 2711P-UM006 · PanelView Plus and Plus 6 Logic Modules: What the Display Series Means
PanelView Plus 6 400/600 and Compact terminals
Interchange: Same cutout and connections across series; confirm the replacement's firmware supports the project's FactoryTalk View ME version.
Rockwell Automation 2711P-UM006
Original PanelView Plus 700 to 1500 terminals
Modular terminal: the logic module (2711P-RP / RP1 / RP2 on CE 4.1; 2711P-RP8 / RP9 on CE 6.0) sets the OS and the FactoryTalk View ME versions it runs.
Fitting a 2711P-RP8 / RP9 logic module to a Series B or later display is Rockwell's published in-panel upgrade to PanelView Plus 6; Series A display modules are not compatible with those logic modules.
Interchange: Displays of the same size interchange. Read the logic module catalog number and firmware on the back; the series letter alone does not tell you what the terminal can run.
Rockwell Automation 2711P-UM001, 2711P-UM006 · PanelView Plus and Plus 6 Logic Modules: What the Display Series Means
Other PanelView Plus and Plus 7 terminals
Interchange: Same cutout and connections across series; confirm the replacement's firmware supports the project's FactoryTalk View ME version.
Rockwell Automation 2711P-UM001 / 2711P-UM008
PanelView Standard terminals (2711)
The catalog suffix, not the series, sets input type, communication port and power; series tracked firmware revisions.
Interchange: Same cutout and connector across series. A later series runs the existing PanelBuilder32 application; an earlier one may need it re-saved for its firmware.
Rockwell Automation 2711-UM014
Kinetix 6000 / 6200 / 6500 modules (2094)
The -S (Kinetix 6000, SERCOS) and -M (Kinetix 6200 / 6500) suffixes are different control families and do not interchange on a rail.
Interchange: Match the suffix. Within the same catalog number, flash the replacement to the firmware revision the Logix project expects before substituting.
Rockwell Automation 2094-UM001, 2094-UM002 · Kinetix 6000 vs Kinetix 6200 / 6500: The -S and -M Suffix
Families without a published series-to-series rule (PowerFlex, Kinetix 300 / 350, Ultra, 1336 and others) are left out on purpose. For those, match the catalog number and firmware of the unit being replaced.