Allen-Bradley Contactors Parts
Motor Control • 71 parts available
Contactors, overload relays, and related motor-control devices start and protect motors in industrial panels.
| Part Number | Description |
|---|---|
| 100-B180ND3 | Magnetic Non-Reversing 180 3 120/110V 60/50Hz Open |
| 100-C09D10 | Mcs-c Contactor, Iec, 9A, 110V 50HZ / 120V 60HZ, Single Pack |
| 100-C09EJ01 | Non-Reversing Contactor 9A 3P 24V DC Open |
| 100-C09EJ10 | Non-Reversing Contactor 9A 3P 24V DC Open |
| 100-C16D10 | Non-Reversing Contactor 16A 3P 120/110V 60/50Hz Open |
| 100-C16EJ01 | Non-Reversing Contactor 16A 3P 24V DC Open |
| 100-C16EJ10 | Bulletin 100-C 3 Pole Contactor, 16 A, 7.5 Kw, 24 V DC Coil |
| 100-C23D10 | Allen Bradley Contactor, Screw Terminals, 11KW/400V, Coil 2 Terminals |
| 100-C23EJ01 | Non-Reversing Contactor 23A 3P 24V DC Open |
| 100-C23EJ10 | Non-Reversing Contactor 23A 3P 24V DC Open |
| 100-C30D00 | Non-Reversing Contactor 30A 3P 120/110V 60/50Hz Open |
| 100-C30D10 | Non-Reversing Contactor 30A 3P 120/110V 60/50Hz Open |
| 100-C37D10 | Contactor, Screw Terminals, Open Poles, Line Side, 37A, 110V, 50HZ, 120V, AC, No |
| 100-C40ZJ400 | Allen Bradley (Rockwell Automation) ICB2 - 100-C40ZJ400 |
| 100-C43D00 | Contactor, 43 A, 110V 50 Hz / 120V 60 Hz., AC, 3 Poles, No, Side Coil, Screw Terminals |
| 100-C43DJ00 | Non-Reversing Contactor 43A 3P 24V DC Open |
| 100-C43EJ00 | Non-Reversing Contactor 43A 3P 24V DC Open |
| 100-C43KJ00 | Non-Reversing Contactor 43A 3P 24V 50/60Hz |
| 100-C55EJ10 | Non-Reversing Contactor 55A 3P 24V DC |
| 100-C60*00 | Allen Bradley 100-C60*00 |
| 100-C6000 | Contactor |
| 100-C60DJ00 | Non-Reversing Contactor 60A 3P 24V DC Open |
| 100-C72D00 | Non-Reversing Contactor 72A 3P 120/110V 60/50Hz Open |
| 100-C72D10 | Non-Reversing Contactor 72A 3P 120/110V 60/50Hz Open |
| 100-C72T00 | Rockwell Automation ICB2 - 100-C72T00 |
| 100-C85D00 | Non-Reversing Contactor 85A 3P 120/110V 60/50Hz Open |
| 100-C85D10 | Non-Reversing Contactor 85A 3P 120/110V 60/50Hz Open |
| 100-C85DJ00 | Non-Reversing Contactor 85A 3P 24V DC Open |
| 100-D180 | Contactor |
| 100-D180D11 | Non-Reversing Contactor 180A 3P 120/110V 60/50Hz Open |
| 100-D180D21 | Contactor |
| 100-D180D31 | Contactor |
| 100-D300 | Contactor |
| 100-DNY41R | Distributed Starter System DSA, 4 Inputs 120V AC, 2 Outputs Relay 250V rated |
| 100-ETAZJ3 | Rockwell Automation ICB2 - 100-ETAZJ3 |
| 100-ETAZJ30 | Rockwell Automation ICB2 - 100-ETAZJ30 |
| 100-F | Contactor |
| 100-FA11 | Rockwell Automation ICB2 - 100-FA11 |
| 100-FA22 | Auxiliary Contact Block Front Mount 2NO+2NC |
| 100-FA31 | Allen Bradley (Rockwell Automation) 100FA31 - 100FA31 |
| 100-FA40 | Auxiliary Contact Block, With 4 No Contact |
| 100-FPTB30 | Rockwell Automation ICB2 - 100-FPTB30 |
| 100-FSC280 | Rc Surge Suppressor, 110...280V AC, 50/60 Hz For 100-C Contactor |
| 100-FSD250 | Surge Suppressor Kit Diode 100S-C 700S-CF 12-250VDC |
| 100-FSV136 | Surge Suppressor Kit Varistor NEMA 00 100S-C 700S-CF 56-136VAC 78-180VDC |
| 100-FSV55 | Surge Suppressor Kit Varistor NEMA 00 100S-C 700S-CF 12-55VAC 12-77VDC |
| 100-K05DJ01 | Non-Reversing Mini Contactor 5A 3P 24V DC Open |
| 100-K09D10 | Non-Reversing Mini Contactor 9A 3P 120/110V 60/50Hz Open |
| 100-K09DJ10 | Contactor, Miniature, 9A, 3P, 24VDC Diode Coil, 1NO Aux. Contact |
| 100-K09DJ300 | Rockwell Automation ICB2 - 100-K09DJ300 |
Contactors buying & repair guidance
Use the catalog string from the nameplate when ordering or quoting. Need a hand? Contact us or request a quote.
Common Contactors failures
- Contact pitting and coil burnout
- Overload trip calibration drift
- Mechanical wear on auxiliary contacts
- Heat-related failures in enclosed starters
Seeing these symptoms? Repair services or search in-stock replacements.
Series & revision differences
NEMA vs IEC sizing and coil voltage must match. Cross-referencing the bulletin (100, 193, 700) avoids mis-sized replacements.
Confirm the full catalog and series before you buy. Condition & authenticity · Quote a specific series
Repair vs replace
Most motor-control devices are replaced as assemblies. Keep the same bulletin family when matching existing heaters, coils, and enclosure kits.
Start a repair quote · Request a replacement quote · Search all inventory
Still have questions?
Find answers to shipping, warranties, repairs, and more.