Allen-Bradley 2097 · Fault code reference

Kinetix 300 Fault Codes

Every fault code a Kinetix 300 reports on the drive's front-panel status display (E followed by two digits), with what each one indicates, as documented in Rockwell Automation publication 2097-UM001.

29 codes · 2097-UM001 · 7 part numbers covered

Kinetix 300 fault code list

Kinetix 300 fault codes
CodeFaultWhat it indicates
E04Motor overtemperatureThe motor thermostat or thermistor tripped: high ambient, excessive current, wiring error or wrong motor selection.
E06Hardware overtravelThe axis moved beyond the physical travel limit input.
E07Feedback lostMotor feedback wiring is open, shorted or missing.
E09Bus undervoltageDC bus voltage dropped below limit with power applied; check incoming AC and the drive enable sequence.
E10Bus overvoltageDC bus voltage above limit, usually excessive regeneration; add or check the shunt resistor.
E11Illegal Hall stateHall feedback inputs are in an invalid state; check motor feedback wiring.
E12Home search failedThe homing sequence did not complete.
E14Ethernet I/O connection lostThe EtherNet/IP I/O connection to the controller dropped.
E16Software overtravelThe axis exceeded a software position limit.
E18OverspeedMotor speed exceeded 125% of maximum rated speed.
E19Excess position errorFollowing error exceeded the position error limit.
E23Drive thermal protectionThe drive thermal model indicates its continuous rating has been exceeded.
E26Index parameter out of rangeAn indexing parameter is outside the allowed range.
E27Absolute move faultAn absolute move was commanded before the axis was homed.
E30Encoder communication faultCommunication was not established with the intelligent (serial) encoder.
E31Encoder data corruptedThe data read from the motor encoder failed its integrity check.
E39Safe Torque Off while enabledThe STO input opened while the drive was enabled.
E43Drive enable inputThe hardware enable input was removed, or enable was attempted without it.
E44Controller changed to PROG modeThe Logix controller was switched to Program mode while the drive was running.
E67Operating system failedSoftware initialization failed, usually a hardware problem; cycle power.
E70Memory module errorThe plug-in memory module is bad or not seated.
E72Drive temperature too highInverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle.
E74Peak current limit exceededOutput current exceeded the drive's peak rating.
E76Blank memory moduleA blank memory module was inserted into the drive.
E91User watchdog timeoutThe explicit-message watchdog expired.
E92Bad batteryThe absolute-encoder battery is low or missing.
E93Acceleration out of capabilityThe commanded acceleration exceeds what the drive / motor can deliver.
E94Motor / feedback cableMotor power or feedback cable fault detected.
E95Wrong indexing modeAn index was commanded in a mode that does not support it.

Is it a hardware fault?

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part, not at wiring, configuration or the application. Those are the faults NJT Automation repairs at component level. A repair is usually cheaper and faster than a replacement for an obsolete Kinetix 300 unit; each part number below links to its stock, repair pricing and test videos.

Faults are read from the drive's front-panel status display (E followed by two digits).

Source

Codes are listed as documented. Fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series. Spotted an error? Tell us and we will correct it.

Related references

Kinetix 300 part numbers these codes apply to

7 catalog numbers, 7 in stock now. Each links to stock, condition, repair pricing and series notes for that catalog number.

Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.