Kinetix 350 fault code list

Kinetix 350 fault codes
CodeFaultWhat it indicates
F 02Illegal Hall stateThe Hall feedback inputs are in an invalid state; check S1 / S2 / S3 wiring and encoder power.
F 03Motor overspeedMotor speed exceeded 125% of maximum rated speed; check phasing, cable noise and tuning.
F 05Motor overtemperatureMotor thermostat, thermistor or encoder temperature sensor reports the factory limit was exceeded.
F 07Motor thermal protectionThe motor thermal model exceeded 110% of its rating; the duty cycle needs more continuous current than the motor allows.
F 10Inverter overcurrentPower transistors shut down for overcurrent: shorted motor cables or windings, or a failed power stage.
F 11Inverter overtemperatureInverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle.
F 13Inverter thermal protectionThe power-transistor thermal model exceeded 110% of its rating.
F 33Bus undervoltageDC bus below limit with three-phase power present (below 275V on a 460V system, 137V on 230V).
F 35Bus overvoltageDC bus above the factory limit, usually excessive regeneration; check shunt sizing.
F 43Feedback lossSin/cos or TTL encoder signal amplitude dropped below the factory limit.
F 45Feedback serial commsMissed or corrupted serial packets from the feedback device exceeded the limit (Kinetix TL motors).
F 47Feedback self testThe feedback device detected an internal error.
F 50 / F 51Hardware overtravel +/-The axis moved beyond the positive or negative physical travel limit.
F 54Excessive position errorThe position error limit was exceeded: partial feedback loss, undersized drive / motor or mechanical problem.
F 55Excessive velocity errorVelocity error exceeded the configured tolerance.
F 56Overtorque limitMotor torque exceeded the user-programmed limit: aggressive profile or mechanical binding.
F 57Undertorque limitMotor torque fell below the user-programmed limit.
F 61Drive enable inputThe hardware enable input was deactivated while the drive was enabled.
F 62Controller initiated exceptionThe controller requested the exception, for example a software overtravel.

Is it a hardware fault?

Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part, not at wiring, configuration or the application. Those are the faults NJT Automation repairs at component level. A repair is usually cheaper and faster than a replacement for an obsolete Kinetix 350 unit; each part number below links to its stock, repair pricing and test videos.

Faults are read from the drive's four-digit status display and the axis fault message in Logix Designer.

Source

Codes are listed as documented. Fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series. Spotted an error? Tell us and we will correct it.

Related references

Kinetix 350 part numbers these codes apply to

9 catalog numbers, 7 in stock now. Each links to stock, condition, repair pricing and series notes for that catalog number.

Disclaimer

Trademarks & Compatibility

All trademarks, service marks, trade names, brand names, and logos displayed on this website are the property of their respective owners. Any references to manufacturers, products, or brands are for identification and compatibility purposes only and do not imply any affiliation with, endorsement by, sponsorship from, or authorization by the respective trademark owners.

Independent Supplier

NJT Automation is an independent supplier of surplus, refurbished, and pre-owned industrial automation equipment. Unless expressly stated otherwise, NJT Automation is not an authorized distributor, dealer, representative, or affiliate of the original equipment manufacturer (OEM) for any products offered on this website.

Product Condition & Warranty

Products sold by NJT Automation may be surplus inventory, discontinued models, older series, or units with earlier manufacturing date codes than those currently available from the OEM or its authorized distribution network. As NJT Automation is not an authorized distributor, manufacturer warranties, support programs, and other OEM services may not apply. Any warranty provided is solely that of NJT Automation, where applicable.

Firmware & Software Licensing

Certain programmable logic controllers (PLCs), drives, HMIs, and other electronic products may require firmware to operate. While some products may include firmware, NJT Automation makes no representations or warranties regarding whether firmware is installed, the firmware version or revision level, its compatibility with your application, or its licensing status.

NJT Automation does not provide, obtain, transfer, or license firmware on behalf of customers. We make no representation regarding your ability or legal right to obtain, download, install, or use firmware from the OEM, its authorized distributors, or any other source. It is the customer's sole responsibility to ensure compliance with all applicable End User License Agreements (EULAs), software licenses, intellectual property rights, and other terms governing the acquisition, installation, and use of firmware.