| Code | Fault | What it indicates |
|---|---|---|
| F 02 | Illegal Hall state | The Hall feedback inputs are in an invalid state; check S1 / S2 / S3 wiring and encoder power. |
| F 03 | Motor overspeed | Motor speed exceeded 125% of maximum rated speed; check phasing, cable noise and tuning. |
| F 05 | Motor overtemperature | Motor thermostat, thermistor or encoder temperature sensor reports the factory limit was exceeded. |
| F 07 | Motor thermal protection | The motor thermal model exceeded 110% of its rating; the duty cycle needs more continuous current than the motor allows. |
| F 10 | Inverter overcurrent | Power transistors shut down for overcurrent: shorted motor cables or windings, or a failed power stage. |
| F 11 | Inverter overtemperature | Inverter thermal switch tripped: failed fan, high cabinet ambient or excessive duty cycle. |
| F 13 | Inverter thermal protection | The power-transistor thermal model exceeded 110% of its rating. |
| F 33 | Bus undervoltage | DC bus below limit with three-phase power present (below 275V on a 460V system, 137V on 230V). |
| F 35 | Bus overvoltage | DC bus above the factory limit, usually excessive regeneration; check shunt sizing. |
| F 43 | Feedback loss | Sin/cos or TTL encoder signal amplitude dropped below the factory limit. |
| F 45 | Feedback serial comms | Missed or corrupted serial packets from the feedback device exceeded the limit (Kinetix TL motors). |
| F 47 | Feedback self test | The feedback device detected an internal error. |
| F 50 / F 51 | Hardware overtravel +/- | The axis moved beyond the positive or negative physical travel limit. |
| F 54 | Excessive position error | The position error limit was exceeded: partial feedback loss, undersized drive / motor or mechanical problem. |
| F 55 | Excessive velocity error | Velocity error exceeded the configured tolerance. |
| F 56 | Overtorque limit | Motor torque exceeded the user-programmed limit: aggressive profile or mechanical binding. |
| F 57 | Undertorque limit | Motor torque fell below the user-programmed limit. |
| F 61 | Drive enable input | The hardware enable input was deactivated while the drive was enabled. |
| F 62 | Controller initiated exception | The controller requested the exception, for example a software overtravel. |
Is it a hardware fault?
Where the manual's only remedy for a code is to replace the unit or module, the code is pointing at a hardware fault inside that part, not at wiring, configuration or the application. Those are the faults NJT Automation repairs at component level. A repair is usually cheaper and faster than a replacement for an obsolete Kinetix 350 unit; each part number below links to its stock, repair pricing and test videos.
Faults are read from the drive's four-digit status display and the axis fault message in Logix Designer.
Source
- Rockwell Automation publication 2097-UM002, Kinetix 350 Single-axis EtherNet/IP Servo Drive User Manual
Codes are listed as documented. Fault behaviour can vary by firmware revision, so confirm against the manual for your unit's series. Spotted an error? Tell us and we will correct it.
Related references
Kinetix 350 part numbers these codes apply to
9 catalog numbers, 7 in stock now. Each links to stock, condition, repair pricing and series notes for that catalog number.
- 2097-V32PR2-LM1 in stockKinetix 350 servo drive
- 2097-V33PR3-LM2 in stockKinetix 350 servo drive
- 2097-V33PR5-LM2 in stockKinetix 350 servo drive
- 2097-V33PR6-LM3 in stockKinetix 350 servo drive
- 2097-V34PR3-LM8 in stockKinetix 350 servo drive
- 2097-V34PR5-LM4 in stockKinetix 350 servo drive
- 2097-V34PR6-LM10 in stockKinetix 350 servo drive
- 2097-V33PR1-LMKinetix 350 servo drive
- 2097-V34PR3-LMs